7 Inch 1000 Nits Outdoor HMI Display Module with 40-Pin LVDS

Product Gallery
Key Specs

Model P/N

HSO70R27BE50-A25

Size

7.0″

Resolution

1024×600

Brightness

1000 (Typ.)(cd/m²)

Viewing Angle

80/80/60/70 degrees (CR≥10)

Connector Type

LVDS, 40-pin FPC

Operating Temp

-20 ~
70 °C

Overall(mm)

164.86(W)×
99.96(H)×
5.5(D)
Upgrade Options (OEM/ODM)

huisoar

HSO70R27BE50-A25

General Features

Brand

huisoar

Panel Size (inch)

7.0"

Model P/N

HSO70R27BE50-A25

Resolution

1024×600

Brightness (nits)

1000 cd/m² (Typ.)

Viewing Angle

80/80/60/70 degrees (CR≥10)

Contrast Ratio

800:1 (typical)

Response Time

25 ms typical, Tr+Tf

Overall (mm)

164.86(W)×
99.96(H) ×
5.5(D) mm

Active Area (mm)

154.21 (W) × 85.92 (H) mm

Refresh Rate

60Hz

Display Colors

16.7M

Panel Type

tft-lcd

Connector Type

LVDS, 40-pin FPC

Operating Temp

-20 ~
70 °C

Touchscreen Type

Optional RTP or CTP

Storage Temp

-30°C to +80°C

Work Mode

Normally white

Pixel Format

1024 × RGB × 600

Control Type

Native LVDS panel input

Operating Environment

High-ambient-light equipment subject to system validation g(Typ./Max.)

Motherboard Type

External LVDS host or suitable controller board g(Typ./Max.)

Designed For

Outdoor-facing and high-ambient-light embedded HMI equipment

7 Inch 1000 Nits Outdoor HMI Display Module with 40-Pin LVDS

1024×600 TN TFT LCD Module with 800:1 Contrast and Optional RTP or CTP

The 7 Inch 1000 Nits Outdoor HMI Display Module is a 1024×600 TN TFT component for equipment interfaces that operate under strong ambient light. It combines 1000 cd/m² typical luminance, a compact 40-pin LVDS connection, 800:1 typical contrast and a 164.86 × 99.96 × 5.5 mm module structure. Optional resistive or capacitive touch configurations can be evaluated for projects requiring direct user interaction.

Direct-sunlight performance depends on the complete optical stack, including cover glass, reflection control, bonding, installation angle and thermal conditions.

Key Specifications at a Glance

ParameterSpecification
Display size7.0 inch
Resolution1024 × 600
Pixel format1024 × RGB × 600
Panel technologyTN TFT
Optical modeNormally white, transmissive
Brightness1000 cd/m² typical
Viewing angle80/80/60/70 typical, CR≥10
Contrast ratio800:1 typical
Response time25 ms typical, Tr+Tf
Interface40-pin LVDS FPC
Active area154.21 × 85.92 mm
Module outline164.86 × 99.96 × 5.5 mm
Dot pitch0.1506 × 0.1432 mm
Backlight27-chip WLED
Backlight reference9.6 V / 180 mA
Backlight life30,000 hours typical
Operating temperature−20°C to +70°C
Storage temperature−30°C to +80°C
Touch configurationOptional RTP or CTP

Final electrical, optical and mechanical values are subject to the approved datasheet, drawing and sample validation.

High-Brightness TN Performance for Equipment Interfaces

The module provides a substantial luminance increase over standard indoor LCD configurations while retaining a cost-conscious TN panel architecture. Its 1024×600 landscape format supports status information, menus, graphical controls, alarms and equipment data without requiring a large enclosure.

1000 cd/m² luminance and use environment

The 1000 cd/m² typical backlight is suitable for outdoor-facing equipment and other high-ambient-light installations where conventional lower-brightness modules may appear washed out.

Brightness alone does not guarantee readability under every direct-sunlight condition.

A sample should be evaluated with the intended cover glass, enclosure angle, surface treatment and operating temperature before the optical configuration is approved.

TN viewing behavior

The specified viewing angles are 80° left, 80° right, 60° up and 70° down under the stated contrast criterion. This asymmetry should be considered when fixing the screen angle in a kiosk, machine console or operator panel.

TN technology can provide practical response and cost characteristics, but the mounting orientation must match the primary user position. A sample review is particularly important when operators will approach the screen from different heights.

Contrast and response

An 800:1 typical contrast ratio supports clear separation among text, icons, status colors and background areas. The listed 25 ms typical response time is appropriate for normal HMI transitions, menu navigation and monitoring data, but it should not be treated as a high-refresh gaming specification.

7 Inch 1000 Nits Outdoor HMI Display Module Interface Compatibility

The standard signal connection is a 40-pin LVDS FPC. LVDS is a panel-level interface rather than a consumer video connector, so the host must generate the module’s native resolution, timing and electrical mapping.

A 40-pin connector is not a universal pinout

A 40-pin LVDS connector does not guarantee compatibility with another 40-pin display.

The engineering review must confirm:

  • LVDS channel and bit mapping
  • native 1024×600 timing
  • pixel-clock and synchronization requirements
  • electrical supply rails
  • FPC contact side and orientation
  • backlight power and control arrangement
  • connector pitch and mechanical position

Connecting an unmatched host or cable can produce no image, unstable output or electrical damage.

HDMI, USB, MIPI and eDP conversion

This module cannot connect directly to HDMI, USB, MIPI DSI or eDP without suitable conversion hardware.

A controller board may be required when the host does not provide the correct native LVDS output. Controller selection should be based on the module timing table and complete pin assignment rather than resolution alone.

Backlight power planning

The backlight is listed as a 27-chip WLED system with a 9.6 V / 180 mA electrical reference. The host design must account for the specified backlight circuit, suitable current regulation and any required enable or brightness-control functions defined in the approved documentation.

Mechanical Integration and Enclosure Fit

The active image area is 154.21 × 85.92 mm. The module outline is 164.86 × 99.96 × 5.5 mm, providing a compact landscape structure for control panels and embedded terminals.

Window and bezel design

The enclosure window should expose the active area without masking edge pixels. Mechanical tolerances, bezel overlap and assembly variation should be included in the front-panel drawing.

The final opening should be determined from the controlled mechanical drawing rather than the active-area dimensions alone.

FPC routing and clearance

The FPC extends from the lower part of the module. The enclosure must provide sufficient bend radius and avoid pressure on the cable exit. Cable routing should also keep the connection away from sharp edges, mounting bosses and high-temperature components.

Touch-stack impact

RTP or CTP is optional rather than standard. Adding touch changes the front outline, thickness, optical reflection, connector arrangement and cover-lens design. The selected touch technology and interface must therefore be specified before the enclosure is finalized.

Recommended Applications and Selection Boundaries

This high-brightness TN module may be considered for:

  • Industrial control panels
  • Outdoor-facing equipment HMIs
  • Agricultural or construction machinery interfaces
  • Kiosk and vending-machine control areas
  • Transportation information terminals
  • Embedded monitoring systems
  • Smart equipment and automation panels

The 7 Inch 1000 Nits Outdoor HMI Display Module is most appropriate when the system already provides compatible LVDS output or can accommodate a dedicated controller board.

Additional engineering qualification is required for installations involving continuous direct sun, extreme thermal loading, vehicle compliance, medical certification, waterproofing, heavy vibration or safety-critical operation.

Customization Options

Project evaluation can include:

  • FPC shape, direction and pin definition
  • Backlight type and brightness
  • Optional RTP or CTP
  • Cover lens dimensions and printing
  • Mechanical adaptation
  • Controller-board matching
  • Packaging and labeling

Optional features should not be treated as standard until the configuration, drawing, interface and sample have been approved.

Procurement Checklist

Before ordering samples or planning production, confirm:

Qualification and production schedule

Native 1024×600 host output

Complete 40-pin LVDS pin assignment

LVDS channel and color-depth mapping

FPC pitch, orientation and contact side

Supply and backlight electrical requirements

Required viewing direction

Target ambient-light environment

Standard module, RTP or CTP configuration

Active-area and enclosure-window fit

Module outline and FPC clearance

Operating and storage temperature

Controller-board requirement

Sample quantity and annual forecast

Application Scenarios

FAQ

about 7 Inch 1000 Nits Outdoor HMI Display Module

Is 1000 cd/m² automatically readable in direct sunlight?

No. The higher luminance improves visibility under strong ambient light, but final readability also depends on reflection, cover glass, surface treatment, bonding, viewing angle and thermal conditions.

Can any 40-pin LVDS controller operate this module?

No. Pin count alone does not establish compatibility. The controller must match the resolution, timing, channel mapping, voltage levels and FPC orientation.

Is touch included as standard?

No. RTP or CTP is optional and must be defined as part of the selected configuration.

Can the module connect directly to HDMI?

No. HDMI requires an appropriate controller or conversion board that outputs the module’s required LVDS timing and electrical format.

Is the module suitable for a fixed-angle operator panel?

It can be a practical choice when the 80/80/60/70 TN viewing profile matches the intended operator position. The installed viewing angle should be tested with a sample.

What is the typical lead time for custom display modules with specific interface requirements?

Lead time for custom display modules depends on the specific configuration, including interface type, touch option, and any optical bonding requirements. For exact lead time for your project with specific interface requirements, please contact our sales team with your detailed specifications so we can provide a confirmed schedule.

Do you offer displays with high refresh rates (e.g., 120Hz) for smooth graphics in transportation information systems?

This 7-inch display module has a standard 60 Hz refresh rate, which is suitable for most HMI and information display applications. For transportation systems requiring 120 Hz or higher, we recommend discussing your specific graphics smoothness needs with our engineering team. We can evaluate if alternative panel options or custom configurations can meet higher refresh rate demands.

What interface options (e.g., LVDS, eDP) are available for your this size panels, and what are the pin configurations?

This 7-inch display module uses a 40-pin LVDS interface as standard. LVDS is the most common interface for industrial TFT panels in this size range due to its low EMI and high data integrity over short distances. For detailed pin assignments and electrical specifications, please request the datasheet for model HSO70R27BE50-A25.

What are the operating temperature ranges for your industrial LCD panels, especially for extended outdoor use?

The operating temperature range for this display module is -20°C to +70°C, with storage from -30°C to +80°C. For extended outdoor use, ensure proper thermal management and consider the complete optical stack. If your application requires wider temperature extremes, please contact us to discuss potential custom solutions.

What are the warranty terms and after-sales service for your display products?

Warranty terms and after-sales service details are provided upon request and depend on the specific order and application. We offer standard warranty coverage for manufacturing defects and provide technical support for integration. For exact warranty duration and service scope, please contact our sales team with your project details.

Need a custom solution or samples?

Request a Sample and Compatibility Review Request a sample and engineering review for the 7 Inch 1000 Nits Outdoor HMI Display Module before finalizing the host board or enclosure. Submit the host-board interface, complete pin assignment, FPC orientation, touch configuration, mechanical drawing, target brightness, installation environment, sample quantity, annual demand, production timing and controller-board requirement.
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.