3.9 Inch Narrow Format TFT LCD for Embedded Status Panels

Product Gallery
Key Specs

Model P/N

HS039BO06A-V1

Size

3.9″

Resolution

480×128

Brightness

750 (Typ.)(cd/m²)

Viewing Angle

ALL (Full viewing angle)

Connector Type

RGB interface

Operating Temp

-20 ~
70 °C

Overall(mm)

105.50(W)×
40.64(H)×
2.95(D)
Upgrade Options (OEM/ODM)

huisoar

HS039BO06A-V1

General Features

Brand

huisoar

Panel Size (inch)

3.9"

Model P/N

HS039BO06A-V1

Resolution

480×128

Brightness (nits)

750 cd/m² (Typ.)

Viewing Angle

ALL (Full viewing angle)

Contrast Ratio

800:1

Response Time

30ms (Typ., Tr+Tf, IPS Standard)

Overall (mm)

105.50(W)×
40.64(H) ×
2.95(D) mm

Active Area (mm)

95.04 × 25.34 mm

Refresh Rate

60Hz

Display Colors

16.7M

Panel Type

tft-lcd, lcm

Connector Type

RGB interface

Operating Temp

-20 ~
70 °C

Touchscreen Type

No touch function

Storage Temp

−30°C to +80°C

Work Mode

Normally black

Pixel Format

480 × 128 pixel bar format

Control Type

External RGB host/controller

Operating Environment

Embedded equipment; final system qualification required g(Typ./Max.)

Motherboard Type

External processor with qualified RGB output g(Typ./Max.)

Designed For

Industrial Equipment, Instrument, Automotive, Consumer Electronics, IoT Devices

3.9 Inch Narrow Format High Brightness TFT LCD for Embedded Status Panels

The Narrow Format TFT LCD provides a native 480 × 128 display area for status information, prompts, indicators and compact graphics in equipment with limited front-panel height. Its 3.9-inch IPS panel combines 750 cd/m² luminance, an RGB interface and a slim 105.50 × 40.64 × 2.95 mm structure.

The non-touch module is intended for embedded integration with a qualified processor or controller. Host timing, electrical levels, pin assignment and backlight driving must be confirmed before hardware release.

Product Summary

This bar-format display occupies less vertical space than a conventional rectangular panel. The active image area measures 95.04 × 25.34 mm, making it suitable for long status windows, compact control surfaces and information strips.

The 480-pixel horizontal canvas can present several icons, short text fields, progress indicators or basic graphs. The 128-pixel vertical dimension supports a focused information hierarchy without requiring a tall enclosure opening.

The native 480 × 128 canvas is intended for narrow status layouts rather than scaled widescreen media.

Key Specifications

SpecificationValue
Display size3.9 inches
Resolution480 × 128 pixels
Panel typeIPS TFT LCD
Active area95.04 × 25.34 mm
Overall dimensions105.50 × 40.64 × 2.95 mm
Luminance750 cd/m²
InterfaceRGB
Driver ICNV3047
TouchNon-touch
Operating temperature−20°C to +70°C

Planning a Native 480 × 128 Interface

Status Data and Compact Graphics

The screen is well suited to concise visual information such as:

  • equipment operating state
  • channel or zone names
  • temperatures and measurements
  • progress or level bars
  • alarms and warning icons
  • network or connection status
  • short menu labels
  • audio or appliance settings

Interfaces should prioritize large, readable elements rather than attempting to reproduce a complete desktop or mobile layout.

Avoiding Distorted Widescreen Content

Standard 16:9 artwork should not be compressed into the 480 × 128 canvas. Compression can distort icons, make text difficult to read and waste the advantages of the narrow format.

The UI should be designed at the native pixel dimensions or generated through a layout engine that preserves the panel’s aspect ratio. Content validation should include the intended viewing distance, font size, icon weight and background contrast.

RGB Integration for the Narrow Format TFT LCD

The Narrow Format TFT LCD uses an RGB panel interface. RGB is not a complete compatibility definition by itself.

Timing, Voltage and Pinout Qualification

Before connecting the panel, engineering should confirm:

  • RGB bit depth
  • pixel-clock frequency
  • horizontal and vertical timing
  • data-enable behavior
  • synchronization polarity
  • logic-voltage levels
  • connector pin assignment
  • FPC contact orientation
  • power rails
  • reset or control signals
  • backlight-driver requirements
  • power-up and power-down sequence

An RGB interface label does not establish compatibility without timing, bit depth, voltage and pin assignment.

A processor that supports RGB output may still require firmware, pin-mux, voltage translation or timing changes.

Scope of the NV3047 Driver IC

NV3047 is identified as the display driver IC. This identifier should be used when checking the approved panel documentation and host configuration.

The IC name alone does not prove a particular initialization sequence, register table, signal mode or voltage requirement. Those items must come from the production drawing, electrical specification and approved sample configuration.

Mechanical Fit in Compact Equipment

Active Area and Enclosure Opening

The active area is 95.04 × 25.34 mm, while the module outline is 105.50 × 40.64 × 2.95 mm.

The enclosure design should separately account for:

  • visible opening
  • inactive border
  • FPC exit position
  • connector access
  • support surface
  • bezel overlap
  • adhesive or frame thickness
  • manufacturing tolerance
  • cover-glass thickness
  • assembly clearance

The listed 2.95 mm dimension applies to the module outline. The finished assembly may be thicker after adding a cover, adhesive, frame, controller board or cable bend.

Luminance and Environmental Boundaries

The standard panel luminance is 750 cd/m². This supports bright interiors and exposed equipment locations where lower-luminance screens may appear weak.

The 750 cd/m² panel rating should be tested behind the intended cover under actual installation lighting.

A protective lens, printed border, air gap, coating and viewing angle can change perceived brightness and reflection. The rating does not independently confirm unrestricted direct-sun readability.

The operating-temperature range is −20°C to +70°C. This is a component value rather than a finished-system guarantee. The final product must also control processor heat, enclosure temperature, backlight conditions and local hot spots.

Recommended Applications

This display may be evaluated for:

  • compact industrial controllers
  • rack-equipment status panels
  • audio control equipment
  • appliance interfaces
  • measurement instruments
  • service and test devices
  • embedded monitoring equipment
  • access-control status displays
  • network equipment
  • narrow machine-information windows

Certification-dependent, outdoor, transport, medical or safety-critical use requires qualification of the complete finished product.

Customization and Sample Approval

Project review may cover:

  • cover-glass dimensions
  • AG, AR or AF treatment
  • FPC length and orientation
  • connector selection
  • RGB mapping
  • luminance adjustment
  • mounting support
  • optical bonding
  • branding
  • packaging

Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability and the requested specification. Sample and standard-module quantities are confirmed separately.

Approval testing should use the intended host, production cable, UI content, cover, enclosure and operating environment.

Procurement Checklist

Submit:

  • native 480 × 128 UI sample
  • host processor or controller model
  • RGB timing specification
  • required RGB bit depth
  • logic-voltage requirements
  • proposed pin map
  • connector and FPC orientation
  • enclosure opening
  • mounting drawing
  • protective-cover specification
  • ambient-light conditions
  • operating-temperature target
  • backlight-driver plan
  • sample quantity
  • annual demand
  • required compliance documents
Application Scenarios

FAQ

What must be checked before replacing another 3.9-inch bar display?

Size and resolution alone are insufficient. Compare the 480 × 128 timing, RGB bit depth, pin assignment, electrical levels, FPC orientation, 95.04 × 25.34 mm active area and 105.50 × 40.64 × 2.95 mm outline. Driver IC and backlight requirements can also differ. Submit both drawings and electrical specifications before treating two modules as interchangeable.

Can the panel connect directly to an HDMI or USB output?

The bare panel cannot connect directly to a conventional HDMI or USB media output. It requires the qualified RGB panel signals and separate backlight driving. A bridge or controller may be necessary when the system begins with HDMI, USB video or another embedded interface. Confirm that the selected board supports the native 480 × 128 timing rather than only standard video resolutions.

How should interface content be prepared for the 480 × 128 screen?

Content should be authored at 480 × 128 pixels or generated responsively for the same aspect ratio. Use short text, high-contrast icons and clear status zones. Avoid shrinking a widescreen dashboard into the narrow canvas. Provide representative menus, warnings and operating data during sample evaluation so font size and information density can be checked on the actual panel.

Is 750 cd/m² sufficient behind a cover lens?

It may be sufficient for many bright indoor installations, but the completed optical stack must be tested. Cover transmission, surface reflections, printed borders and air gaps can reduce apparent visibility. Evaluate the 750 cd/m² panel with the intended cover treatment, UI colors, mounting angle and ambient lighting before approving the final luminance level.

What electrical information is required for RGB host matching?

Provide the host’s pixel clock, RGB bit depth, timing table, data-enable behavior, synchronization polarity, logic voltage, proposed pin assignment and power sequence. The panel is identified as RGB and uses NV3047, but those labels do not define the complete electrical interface. Host matching should be completed before PCB routing or production-cable release.

What is the minimum order quantity (MOQ) for custom display solutions?

For procurement guidance, we recommend contacting our sales team to discuss your volume requirements and any customization needs. They can provide MOQ details based on your specific project scope and order size.

Can you provide high brightness displays with 1000+ nits that maintain performance in direct sunlight for outdoor industrial applications?

The product information lists a brightness of 750 nits for this model, which is suitable for many indoor and shaded outdoor applications. For displays with 1000+ nits for direct sunlight, we can explore custom options. Please confirm your exact brightness requirement and environmental conditions with our engineering team to determine feasibility and next steps.

Do you offer displays with wide viewing angles and high contrast ratios for industrial HMIs?

Yes, this display offers full viewing angles (ALL) and a high contrast ratio of 800:1, making it well-suited for industrial HMIs. The IPS panel technology ensures consistent image quality from various viewing positions, which is critical for operator interfaces in control panels and equipment.

What are the operating temperature ranges for your industrial control displays, especially for environments below -20°C or above 70°C?

For environments below -20°C or above 70°C, this specific model is If your application requires extended temperature ranges, please contact us with your exact requirements so we can recommend a suitable display or discuss custom solutions. Exact performance at temperature extremes should be confirmed on request.

Can you develop a square LCD screen with a specific resolution and aspect ratio?

We can develop custom LCD screens with specific resolutions and aspect ratios. While this model has a narrow format (480×128), our engineering team can assess your requirements for a square display. Please provide your desired resolution, aspect ratio, and other specifications so we can evaluate feasibility and provide a tailored solution.

Need a custom solution or samples?

Submit Your Display Requirements For a Narrow Format TFT LCD review, submit the host processor, RGB timing, bit depth, voltage levels, pin map, FPC orientation, native 480 × 128 content, enclosure drawing, cover-glass plan, ambient-light target, sample quantity and annual demand. Engineering review covers RGB compatibility, timing, electrical levels, backlight driving, mechanical fit, optical performance and customization feasibility.

Recommended: Same Size

(3.9")

Alternatives
No data was found
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.