13.3″ TFT 1920×1080 1000 Nits Outdoor High Brightness Medical Display

Product Gallery
Key Specs

Model P/N

HS133015B0

Size

13.3″

Resolution

1920×1080

Brightness

1000 (Typ.)(cd/m²)

Viewing Angle

80°/80°/80°/80° L/R/U/D

Connector Type

30-pin eDP

Operating Temp

-20 ~
60 °C

Overall(mm)

307.6(W)×
183.5(H)×
5.5(D)
Upgrade Options (OEM/ODM)

huisoar

HS133015B0

General Features

Brand

huisoar

Panel Size (inch)

13.3"

Model P/N

HS133015B0

Resolution

1920×1080

Brightness (nits)

1000 cd/m² (Typ.)

Viewing Angle

80°/80°/80°/80° L/R/U/D

Contrast Ratio

1000:1 (Min.)

Response Time

8ms

Overall (mm)

307.6(W)×
183.5(H) ×
5.5(D) mm

Active Area (mm)

293.76 (W) × 165.24 (H) mm

Refresh Rate

60Hz

Display Colors

16.7M

Panel Type

tft-lcd, lcm

Connector Type

30-pin eDP

Operating Temp

-20 ~
60 °C

Touchscreen Type

Optional Custom Touch Screen

Storage Temp

−20°C to +70°C

Work Mode

Normally black, transmissive

Operating Environment

Bright-ambient professional equipment after system-level qualification g(Typ./Max.)

Designed For

Industrial displays, outdoor high-brightness displays, digital signage, professional equipment displays for high-ambient-light environments, medical equipment displays, industrial automation systems, instrument displays, logistics equipment interfaces, and qualified embedded display applications.

13.3" TFT 1920x1080 1000 Nits Outdoor High Brightness Medical Display

A 1920x1080 1000 Nits Outdoor High Brightness Medical Display is a practical component choice when professional equipment needs Full HD detail, stronger luminance and compact eDP integration. The 13.3-inch TFT-LCD combines 1000 cd/m² typical brightness, IPS full-view performance, a 293.76 × 165.24 mm active area and a 30-pin eDP connection. Its standard configuration is non-touch, making it suitable for medical-equipment display assemblies, industrial automation panels, logistics terminals and outdoor-facing professional devices after system-level qualification.

Product Summary

This 13.3-inch module provides a native 1920 × 1080 image area in a 16:9 format. That combination gives equipment designers enough workspace for status dashboards, measurement values, operating controls, alarms and graphical information without moving to a larger panel.

Full HD Workspace for Equipment Interfaces

Native Full HD resolution helps preserve small text, graphical indicators and multi-zone UI layouts. For medical instruments, automation controllers and logistics equipment, this can be useful when several information groups must remain visible on the same screen.

The active display area measures 293.76 × 165.24 mm, giving enclosure designers a clear reference for the visible image opening.

IPS Full-View Performance

The IPS hard-screen structure supports a full-view configuration with 80°/80°/80°/80° viewing angles in the left, right, up and down directions.

This allows interface content to remain visible when the operator is not positioned directly on the center axis, which is useful for shared equipment panels and fixed installations viewed from different positions.

Key Specifications

ParameterSpecification
Display Size13.3 inches
Resolution1920 × 1080 pixels
Aspect Ratio16:9
Panela-Si IPS TFT-LCD
Work ModeTransmissive
Brightness1000 cd/m² typical
Contrast Ratio1000:1 minimum
Viewing Angle80°/80°/80°/80° L/R/U/D
Display Colors16.7M
Active Area293.76 × 165.24 mm
Detailed Outline307.60 × 183.05 × 5.50 mm
InterfaceeDP, 30 pins
BacklightWLED
TouchNo touch
Operating Temperature−20°C to +60°C
Storage Temperature−20°C to +70°C

1000 cd/m² Performance in Bright Ambient Light

The fixed 1000 cd/m² typical luminance gives this module additional optical headroom for equipment installed near strong lighting, windows or outdoor-facing positions.

Brightness Versus Finished-System Readability

A 1000 cd/m² panel does not by itself establish finished-system direct-sun readability behind the final front stack.

Cover glass, reflection, installation angle, enclosure shading and thermal conditions can all affect the final image. Projects intended for outdoor-facing equipment should therefore validate the complete display stack under the actual target lighting instead of approving the design from panel luminance alone.

1000:1 Minimum Contrast

The specified contrast ratio is 1000:1 minimum. Combined with Full HD resolution, this supports clear separation between interface backgrounds, text, icons and graphical information.

For equipment UI design, the final contrast seen by the operator should still be evaluated after any front cover or protective window is added.

Integrating the 1920x1080 1000 Nits Outdoor High Brightness Medical Display

Electrical integration should start from the approved module definition rather than connector count alone.

30-Pin eDP Qualification

The module uses a 30-pin eDP signal connection. Native 1920 × 1080 timing, the complete pin assignment, connector geometry, cable orientation, voltage requirements and eDP link parameters should all be confirmed before controller-board or cable release.

A matching 30-pin eDP connector does not guarantee lane, link-rate, timing, voltage or pin compatibility.

This is particularly important when replacing another 13.3-inch Full HD panel, because identical screen size and connector count do not establish electrical interchangeability.

Standard Non-Touch Architecture

The standard module is non-touch.

Equipment using keys, rotary controls, external buttons or another input method can integrate the display without adding an LCD-side touch path. If touch input is required, the touch sensor, controller, communication interface, cover structure and combined mechanical envelope should be engineered as a separate configuration.

Mechanical Fit and Enclosure Planning

Mechanical release requires attention because the detailed and rounded dimensional records are not identical.

Active Area and Module Outline

The visible active area is 293.76 × 165.24 mm. The more detailed module reference is 307.60 × 183.05 × 5.50 mm.

These dimensions serve different purposes: the active area controls the visible window, while the complete module outline controls bezel clearance, mounting and internal enclosure space.

5.0 mm Versus 5.50 mm Thickness

A rounded parameter entry gives approximately 307 × 183 mm with a 5 mm maximum-thickness value, while the detailed configuration gives 307.60 × 183.05 × 5.50 mm.

The approved production drawing must therefore control enclosure and tooling release.

Do not freeze the housing from the rounded thickness entry alone.

Temperature Range and Outdoor-Facing Integration

The module is specified for operation from −20°C to +60°C and storage from −20°C to +70°C.

These are component-level temperature limits. They do not establish the environmental rating of a complete outdoor product. Internal enclosure temperature, solar load, ventilation, moisture, contamination, sealing and thermal design still need to be qualified for the finished system.

Within bright-ambient professional equipment, the 1920x1080 1000 Nits Outdoor High Brightness Medical Display should therefore be evaluated as one part of the complete optical, electrical and environmental design.

Medical, Automation and Logistics Applications

Medical-Equipment Display Integration

The Full HD resolution, 13.3-inch size, 1000 cd/m² luminance and wide-view IPS structure make this panel suitable for evaluation in medical-equipment instrument interfaces that require a detailed graphical display.

Medical-equipment application wording does not establish finished-device medical certification.

The completed equipment still needs the applicable safety, EMC, cleaning, optical-performance and regulatory qualification for its intended use.

Industrial Automation Interfaces

For industrial automation equipment, the display provides a useful 16:9 canvas for status information, menus, alarm messages and process graphics.

The non-touch architecture can be appropriate for machines using external control hardware, while the eDP interface fits embedded architectures after complete host and pinout qualification.

Logistics and Parcel-Locker Equipment

The same module can be evaluated for logistics parcel-locker displays and other professional information terminals requiring Full HD content in a compact format.

Outdoor-facing or semi-outdoor installations should additionally define cover-glass transmission, reflection, enclosure thermal conditions and environmental protection at the finished-system level.

Configuration and Customization

Project evaluation can cover eDP cable and pin definition, front cover glass, AG or AR treatment, optical bonding, separately engineered touch, brightness/front-stack optimization, enclosure adaptation, branding and packaging.

Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability and the requested specification. Sample and standard-module quantities are confirmed separately.

Procurement Checklist

Before sample approval or design release, confirm the exact production revision, native 1920 × 1080 timing, full 30-pin eDP assignment, connector and cable orientation, panel electrical requirements, WLED backlight requirements, 293.76 × 165.24 mm active area and approved mechanical drawing.

Also confirm the 1000 cd/m² luminance tolerance, 1000:1 minimum contrast requirement, 80°/80°/80°/80° viewing specification, non-touch configuration, −20°C to +60°C operating range, −20°C to +70°C storage range, front-window optical stack and actual equipment environment.

For medical projects, define finished-device safety, EMC, cleaning and regulatory requirements. For outdoor-facing equipment, define reflection, sealing and thermal conditions independently of panel brightness.

Application Scenarios

FAQ

About Outdoor High Brightness Medical Display

What must be checked before replacing another 13.3-inch 30-pin eDP panel?

Matching size, resolution and connector count are not enough for replacement approval. This module uses 1920 × 1080 resolution and a 30-pin eDP connection, but the complete pin definition, eDP link parameters, panel power, connector geometry and cable orientation still need comparison with the existing system. Submit the current panel specification and host-board information before approving a replacement.

Is 1000 cd/m² sufficient behind a protective front window?

The panel provides 1000 cd/m² typical luminance, but finished-equipment readability depends on more than the bare-panel value. A front window can introduce transmission loss and reflection, especially in bright ambient conditions. Test the planned glass, installation angle and actual lighting together with the module before fixing an outdoor readability requirement.

Which thickness should be used when designing the enclosure?

Use the approved production drawing for final mechanical release. The detailed configuration gives 307.60 × 183.05 × 5.50 mm, while a rounded parameter entry gives approximately 307 × 183 mm and 5 mm thickness. That 0.50 mm difference can affect bezel clearance or mounting depth, so the production drawing should be locked before tooling.

What changes if the equipment requires touch control?

Touch must be engineered as a separate configuration because the standard module is non-touch. A touch version would require a sensor structure, controller, communication path, FPC routing, cover design and revised combined thickness. Submit the required touch method and enclosure drawing so the complete display-and-touch stack can be evaluated rather than assuming touch can simply be added without mechanical changes.

What should be confirmed before using this display in medical equipment?

The display characteristics can support medical-equipment interface development, but component specifications do not establish medical certification. Confirm the 1920 × 1080 UI requirement, 1000 cd/m² optical target, 30-pin eDP integration, non-touch input architecture and operating environment first. Then define the finished device's safety, EMC, cleaning, optical and regulatory requirements before formal qualification.

Need a custom solution or samples?

Request a Sample and Engineering Review For a 1920×1080 1000 Nits Outdoor High Brightness Medical Display evaluation, submit your host/controller platform, current panel reference or complete 30-pin eDP definition, enclosure drawing, front-window or touch requirement, target lighting environment, sample quantity and forecast annual demand. Engineering review covers eDP compatibility, electrical and backlight requirements, optical conditions, mechanical fit, non-touch or separate-touch architecture, operating-temperature limits and project-specific customization.
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.