Key Specs

Model P/N

HS650HNX01-A01-BK

Size

65″

Resolution

3840×2160

Brightness

2500 (Typ.)(cd/m²)

Viewing Angle

89/89/89/89 minimum, CR ≥ 10

Connector Type

V-BY-ONE

Operating Temp

-20 ~
70 °C

Overall(mm)

1510.5(W)×
886(H)×
68.5(D)
Upgrade Options (OEM/ODM)

huisoar

HS650HNX01-A01-BK

General Features

Brand

huisoar

Panel Size (inch)

65"

Model P/N

HS650HNX01-A01-BK

Resolution

3840×2160

Brightness (nits)

2500 cd/m² (Typ.)

Viewing Angle

89/89/89/89 minimum, CR ≥ 10

Contrast Ratio

1200:1

Response Time

6 ms (Tr/Td)

Overall (mm)

1510.5(W)×
886(H) ×
68.5(D) mm

Active Area (mm)

1428.48 × 803.52 mm

Refresh Rate

60Hz

Display Colors

16.7M colors

Panel Type

tft-lcd, lcm

Connector Type

V-BY-ONE

Surface Treatment

5mm AR Anti-Reflection Glass, IK10

Operating Temp

-20 ~
70 °C

Touchscreen Type

Optional (Capacitive, 10 Points)

Storage Temp

−30°C to +80°C

Work Mode

IPS, Normally Black, Transmissive

Pixel Format

RGB Vertical Stripe

Touch Interface

Optional (USB)

Control Type

Automatic brightness adjustment through a light sensor

Operating Environment

IP66 outdoor public-display installations g(Typ./Max.)

Motherboard Type

Optional Android 11 with 4 GB RAM and 32 GB storage g(Typ./Max.)

Designed For

Outdoor Signage, Advertising, Transportation,Stadium screens, smart-city infrastructure and exposed outdoor public displays

65 Inch Fanless Outdoor Signage Display for Smart Cities

This 65-inch 4K outdoor display combines passive cooling, IP66 protection and 2500 cd/m² luminance for exposed public installations.

Product Summary

A Fanless Outdoor Signage Display provides a deployment-ready platform for public media systems that must operate around sunlight, rain, dust and changing ambient temperatures. This 65-inch unit combines a native 3840 × 2160 image, 2500 cd/m² luminance, passive heat dissipation, IP66 protection and 5 mm front anti-reflection IK10 glass.

The complete enclosure measures 1510.5 × 886 × 98.5 mm and uses a 400 × 600 mm mounting pattern. AC100–240 V input and a listed consumption below 500 W give system designers defined references for electrical distribution, bracket selection and heat-load planning. Optional Android, touch and network configurations support both passive media playback and interactive public-information systems.

Key Specifications

ParameterValue
Display size65 inches
Native resolution3840 × 2160 pixels
Luminance2500 cd/m²
Active area1428.48 × 803.52 mm
Aspect ratio16:9
Contrast ratio1200:1
Viewing angle89/89/89/89 minimum, CR ≥ 10
Response time6 ms typical, Tr/Td
Display colors16.7M
Front protection5 mm anti-reflection glass, IK10
Ingress protectionIP66
Thermal systemPassive heat dissipation, fanless
Brightness controlAutomatic adjustment through a light sensor
Backlight referenceListed MTBF: 50,000 hours
Unit inputAC100–240 V
Listed consumptionLess than 500 W
Dimensions1510.5 × 886 × 98.5 mm
Mounting400 × 600 mm, four M8 points
Operating temperature−20°C to +70°C
Storage temperature−30°C to +80°C

Optional configurations include Android 11 with 4 GB RAM and 32 GB storage, 10-point capacitive touch, Wi-Fi, Ethernet, 4G, HDMI, RJ45 and USB. These options should be defined in the order specification rather than assumed to be present in every unit.

Passive Cooling in a Fanless Outdoor Signage Display

Qualify Solar Load and Installation Orientation

Passive heat dissipation removes mechanical fan components from the cooling architecture, but it does not remove the need for a thermal study. Outdoor enclosures are affected by internal electrical heat, ambient temperature and solar radiation on the front glass and housing.

The installation review should document compass orientation, direct-sun duration, nearby heat-reflective surfaces and expected operating hours. RisingStar describes fanless outdoor signage as relying on heat-dissipation structures rather than fan-driven airflow, while other manufacturers similarly position passive cooling as a way to eliminate fan-related moving parts.

A passive-cooling label does not remove the need to validate solar load, mounting clearance and the less-than-500-watt system heat budget.

Preserve Heat-Rejection Clearance

The rear and side surfaces must remain able to reject heat after installation. A decorative housing, wall recess or tightly packed mounting structure can change thermal behavior even when the standalone display operates within its specified −20°C to +70°C range.

The bracket and cabinet design should maintain rear clearance, avoid blocking heat-dissipation surfaces and provide safe service access. A representative sample should be tested with the planned mounting geometry and operating schedule.

IP66 Enclosure and Front Protection

Maintain the Sealed System Boundary

The standard display is specified with IP66 ingress protection. The rating supports outdoor use, but final system integrity still depends on cable entries, doors, connectors, fasteners and any installation modifications.

An IP66 enclosure rating can be compromised by unapproved cable entries, service openings or installation changes.

Projects using external power, HDMI, RJ45 or USB connections should define how those connections pass through the outdoor boundary. The installer should also confirm that brackets, penetrations and service procedures do not damage seals or create water paths. Industry guidance repeatedly identifies cable entries, cabinet sealing and service access as critical parts of outdoor-display protection.

Use the 5 mm AR IK10 Front Structure

The 5 mm front anti-reflection glass reduces surface reflection while providing an IK10-rated protective barrier. This matters in unattended public installations where optical clarity and resistance to impact both affect system performance.

The final image should still be evaluated under the real viewing angle and sunlight direction. Front-glass cleaning methods, edge sealing and replacement procedures should be included in the maintenance plan.

4K Content and Automatic Brightness Control

Prepare Native 3840 × 2160 Content

The 65-inch screen uses a native 3840 × 2160 raster. Advertising, public-information and wayfinding content should be produced at the native resolution to retain text edges, icons and detailed imagery.

The selected media architecture must support the approved 4K timing and output path. External-player projects should confirm HDMI implementation, refresh requirements and content-protection needs. Integrated Android projects should verify the exact board configuration, software environment and playback workload.

A 4K panel still requires an approved 3840 × 2160 content and playback path.

Validate Light-Sensor Behavior on Site

Automatic brightness adjustment through a light sensor can reduce unnecessary output under lower ambient light and increase brightness when conditions become stronger. The sensor position, control range, response timing and nighttime brightness policy should be tested after the display is mounted.

Ambient-light sensing is especially relevant in smart-city and transport installations where lighting conditions change throughout the operating period. Outdoor-signage guidance commonly treats brightness control as part of both readability and energy management.

Android, External Input and Network Architecture

Choose an Integrated or External Playback Route

Android 11 with 4 GB RAM and 32 GB storage is an optional configuration. It may suit standalone playback or compatible signage applications where the media player is integrated into the display.

An external architecture can instead use an optional HDMI input and a separate commercial player. That route may be preferable when the buyer already has a standardized CMS, remote-management platform or approved enterprise player.

The selected route should state:

  • Content-management platform
  • Native 4K playback requirement
  • Offline playback behavior
  • Automatic recovery after power loss
  • Remote monitoring requirements
  • Storage capacity
  • Security and software-update policy

Keep Touch and Network Hardware Configuration-Specific

Optional communication routes include Wi-Fi, Ethernet and 4G. Optional physical I/O includes HDMI ×1, RJ45 ×1 and USB ×2. Optional touch uses a 10-point capacitive structure.

Optional Android 11, network hardware and 10-point capacitive touch are configuration choices rather than standard inclusions.

Touch projects must confirm the touch controller, operating-system support, communication interface, cover-glass stack and behavior under rain, gloves or surface contamination. Network projects should define whether Ethernet, Wi-Fi or cellular communication is required and how the equipment will be managed securely.

Mechanical, Mounting and Power Integration

The enclosure measures 1510.5 × 886 × 98.5 mm. Its mounting interface is 400 × 600 mm with four M8 points and a maximum thread depth of 12 mm. The final unit weight remains to be confirmed before the wall, pole, frame or kiosk structure is released.

The mounting design should account for:

  • Display weight after confirmation
  • Wind load
  • Orientation
  • Fastener engagement
  • Bracket stiffness
  • Cable bend radius
  • Rear service space
  • Glass replacement access
  • Drainage and water paths
  • Thermal clearance

The AC100–240 V supply and less-than-500-watt listed consumption should be incorporated into the circuit, grounding, surge-protection and thermal plans. Additional media, networking and touch hardware may increase the complete system load.

Application Fit for Smart-City and Stadium Media

This Fanless Outdoor Signage Display is suited to smart-city information points, stadium screens, outdoor advertising, transit information, EV charging, fuel-retail media and public kiosks where a large 4K canvas must operate in an exposed environment.

Its 65-inch active image area supports advertising, service messages, maps, event information and public notices that must be read from longer distances. The IP66 enclosure, IK10 glass and passive cooling architecture make it materially different from an indoor commercial screen placed inside a basic cabinet.

The final application still requires site-specific optical, thermal, structural and electrical approval. A roadside screen receiving sustained direct sun presents a different load from a shaded concourse display, even when both use the same hardware.

Configuration and Procurement

Available project directions include:

  • Optional Android 11 media architecture
  • 4 GB RAM and 32 GB storage
  • Optional HDMI, RJ45 and USB
  • Optional Wi-Fi, Ethernet and 4G
  • Optional 10-point capacitive touch
  • Touch-controller and firmware selection
  • Brightness-control settings
  • Cover-glass treatment
  • Optical bonding
  • Cable-entry sealing
  • Mounting adaptation
  • Thermal design
  • Enclosure-material review
  • Branding and packaging

Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability and the requested specification. Sample and standard-display quantities are confirmed separately.

Procurement Checklist

Confirm these items before sample approval:

  • Approved model-specific specification and mechanical drawing
  • Native 3840 × 2160 content and playback path
  • 2500 cd/m² target under real site lighting
  • Automatic light-sensor location and control behavior
  • Viewing-angle sequence and direction order
  • 5 mm anti-reflection IK10 glass
  • IP66 documentation and sealing construction
  • Cable-entry and service-door protection
  • Site orientation and solar exposure
  • Maximum ambient temperature
  • Daily operating schedule
  • Passive-cooling validation
  • Less-than-500-watt system consumption
  • Android or external-player architecture
  • Android application and CMS compatibility
  • Required HDMI, RJ45 and USB ports
  • Wi-Fi, Ethernet or 4G requirement
  • Touch requirement
  • Touch controller and interface
  • Rain, glove and contamination test conditions
  • AC100–240 V supply
  • 1510.5 × 886 × 98.5 mm enclosure fit
  • 400 × 600 mm mounting pattern
  • Four-M8 fasteners and 12 mm maximum depth
  • Final unit weight
  • Wind and structural load
  • −20°C to +70°C operating requirement
  • −30°C to +80°C storage requirement
  • Sample criteria
  • Quantity and annual demand
Application Scenarios

FAQ

About 65 Inch Fanless Outdoor Signage Display

What must be checked before passive cooling is approved for the installation?

Passive cooling should be approved against the complete site heat load, not only the ambient-temperature specification. This display combines 2500 cd/m² luminance with less than 500 W listed consumption and a −20°C to +70°C operating range. Submit the site orientation, direct-sun duration, mounting clearance and operating schedule so the sample can be evaluated under representative thermal conditions.

How can installation work affect the IP66 enclosure boundary?

Cable entries, replacement doors, brackets and unapproved holes can alter the sealed system even when the original enclosure is IP66. The optional HDMI, RJ45 and USB connections must pass through an approved outdoor connection route. Provide the cable schedule, gland or connector details and service-access plan so sealing can be assessed before the cabinet or support structure is finalized.

When should optional Android be selected instead of an external HDMI player?

Use the optional Android 11 route when compatible standalone playback, local storage and integrated network management meet the project requirements. Choose an external HDMI player when an existing enterprise CMS, security platform or standardized media player must be retained. Confirm native 3840 × 2160 output, startup behavior, offline operation and remote recovery for either architecture.

What must be confirmed for 10-point capacitive touch through the front glass?

The touch version requires confirmation of the sensor, controller, communication interface and behavior through the 5 mm front protective structure. The standard display glass is anti-reflection and IK10, while 10-point capacitive touch is optional. Submit the required operating system, glove conditions, rain or water behavior, interface preference and user-interface layout for touch-stack evaluation.

Which mechanical and power data control sample approval?

Sample approval should use the complete 1510.5 × 886 × 98.5 mm enclosure, 400 × 600 mm mounting pattern, four M8 points and 12 mm maximum thread depth. The AC100–240 V supply and less-than-500-watt consumption must also be included in the electrical and thermal design. Final display weight, wind load, bracket stiffness and rear service clearance must be confirmed before structural release.

Need a custom solution or samples?

Request a Sample and Outdoor-System Review For a Fanless Outdoor Signage Display project, submit the site orientation, solar exposure, ambient-temperature range, operating schedule, content resolution, media-player or CMS architecture, required I/O and network, touch requirement, mounting drawing, AC supply, power budget, cable-entry plan, sample quantity and annual demand. Engineering review covers optical visibility, passive thermal performance, the IP66 system boundary, Android or external-player architecture, touch integration, network scope, mechanical fit, mounting load, electrical distribution and available customization.
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.