13.3 Inch Full HD LCD Module eDP 30 Pin Display for Embedded HMI

Product Gallery
Key Specs

Model P/N

HS133EA0T-MTP2005U

Size

13.3″

Resolution

1920×1080

Brightness

300 (Typ.)(cd/m²)

Viewing Angle

85/85/85/85 (Left/Right/Up/Down)

Connector Type

30-pin eDP FPC

Operating Temp

-20 ~
70 °C

Overall(mm)

305.35(W)×
187.82(H)×
4.7(D)
Upgrade Options (OEM/ODM)

huisoar

HS133EA0T-MTP2005U

General Features

Brand

huisoar

Panel Size (inch)

13.3"

Model P/N

HS133EA0T-MTP2005U

Resolution

1920×1080

Brightness (nits)

300 cd/m² (Typ.)

Viewing Angle

85/85/85/85 (Left/Right/Up/Down)

Response Time

12ms

Overall (mm)

305.35(W)×
187.82(H) ×
4.7(D) mm

Active Area (mm)

293.76 × 165.24 mm

Refresh Rate

60Hz

Display Colors

16.7M colors

Panel Type

tft-lcd

Connector Type

30-pin eDP FPC

Operating Temp

-20 ~
70 °C

Touchscreen Type

Optional capacitive touch

Storage Temp

-30 °C to 80 °C

Work Mode

Normally black

Pixel Format

1920 × 1080 pixels, 16:9

Operating Environment

Determined by final enclosure, optical stack and qualification requirements g(Typ./Max.)

Designed For

Embedded HMI, compact OEM equipment, industrial control panels, operator interfaces, equipment control interfaces, machine control panels, factory automation equipment, industrial monitoring systems, test instruments, embedded display systems, compact control terminals, production line terminals, equipment configuration panels, indoor control equipment, and custom enclosure-based embedded equipment.

13.3 Inch Full HD LCD Module for Embedded HMI

A slim 1920 × 1080 TFT display with a 30-pin eDP connection and an optional capacitive-touch configuration for embedded equipment.

Product Overview

The 13.3 Inch Full HD LCD Module provides a compact 16:9 display area for embedded systems that require detailed graphics, readable text and a relatively thin mechanical structure. Its 1920 × 1080 resolution supports equipment interfaces that combine operating data, status information, menus, diagrams and visual controls on one screen.

The active image area measures 293.76 × 165.24 mm. The complete module outline is 305.35 × 187.82 × 2.70 mm, giving mechanical engineers a defined starting point for enclosure depth, bezel placement and internal clearance planning.

The standard display path uses a 30-pin eDP connection. Capacitive touch is available as an optional project configuration and must not be assumed to be included with every module.

Key Specifications at a Glance

SpecificationConfirmed value
Display size13.3 inch
Resolution1920 × 1080 pixels
Aspect ratio16:9
Panel technologyA-Si TFT LCD
Display interfaceeDP
Display connector30-pin FPC
Active area293.76 × 165.24 mm
Module outline305.35 × 187.82 × 2.70 mm
Touch configurationCapacitive touch optional
Operating temperature−20°C to +70°C
Storage temperature−30°C to +80°C

Full HD Visual Workspace

1920 × 1080 Interface Layout

Full HD resolution provides enough pixel capacity for dashboards, setup pages, equipment diagrams and multi-column data views. The 16:9 format is suitable for interfaces that place navigation controls beside charts, video windows, alarms or machine-status information.

Resolution alone does not determine whether text and controls will be comfortable to use. UI scaling, font size, touch-target dimensions and the intended viewing distance should be tested on a physical sample before the graphical interface is approved.

Active Image Area

The 293.76 × 165.24 mm active area defines the visible image region. Enclosure designers should distinguish this area from the full 305.35 × 187.82 mm module outline when calculating bezel overlap and the visible window.

The active area should remain unobstructed after the cover lens, front frame and adhesive structure are installed. Excessive overlap can conceal image content or create uneven visual borders.

Integrating the 13.3 Inch Full HD LCD Module

30-Pin eDP Host Qualification

The module uses a 30-pin eDP display connection, but connector count is only one part of compatibility. The host and panel must also agree on link configuration, timing, electrical levels, power requirements, connector location, contact orientation and complete pin assignment.

A matching 30-pin connector does not guarantee eDP timing, lane or pin compatibility.

Before releasing a controller PCB or display cable, compare the host output specification with the approved module interface document. An HDMI, DisplayPort, MIPI DSI, LVDS or USB video output cannot be connected directly unless suitable conversion hardware is included.

Optional Capacitive-Touch Configuration

Capacitive touch is a selectable configuration rather than a confirmed standard feature. A touch-equipped assembly requires separate confirmation of the sensor structure, controller, communications interface, connector, cable, supply requirements and cover-lens design.

The eDP path carries display information; it does not automatically carry the touch-control connection.

Projects that require touch should specify the intended host interface, required touch-point count, operating system or firmware environment, cover-glass dimensions and bonding approach. These items affect the complete display assembly even when the LCD panel remains unchanged.

Slim Mechanical Integration

2.70 mm Module Profile

The confirmed module outline is 305.35 × 187.82 × 2.70 mm. This thin panel profile is useful for compact terminals and shallow equipment housings, but the LCD depth is not necessarily the final installed depth.

The completed mechanical stack may also include:

  • rear support structure;
  • display and touch cables;
  • connector clearance;
  • optional touch sensor;
  • cover lens;
  • adhesive or optical bonding;
  • bezel overlap;
  • mounting brackets or retention features.

The approved mechanical drawing should control enclosure release rather than the three outline numbers alone.

Temperature and Enclosure Planning

The confirmed operating range is −20°C to +70°C, with storage from −30°C to +80°C. These values define module temperature boundaries but do not establish complete equipment certification or environmental protection.

Thermal design should consider heat from the controller board, power conversion, backlight system and enclosed air volume. The front structure must also provide the required mechanical support without twisting or point-loading the thin panel.

The stated temperature range does not by itself establish automotive, medical, outdoor, waterproof or high-vibration qualification.

Recommended Application Profiles

This TFT module can be evaluated for:

  • embedded HMI terminals;
  • industrial control panels;
  • smart equipment interfaces;
  • compact operator consoles;
  • test and service equipment;
  • OEM control products;
  • display-only terminals;
  • optional-touch user interfaces.

The 13.3-inch format is particularly useful when a project needs more interface area than a small HMI but cannot accommodate a large monitor-style assembly.

Projects requiring direct HDMI input, a controller board, finished enclosure, integrated speakers or standard USB touch should use a controller-equipped display product or define those additional assemblies separately.

Procurement and Sample Approval

Before approving the 13.3 Inch Full HD LCD Module, confirm the complete interface, power, mechanical and optional-touch configuration.

Procurement Checklist

  • Native 1920 × 1080 host timing
  • eDP lane count and link rate
  • Complete 30-pin assignment
  • Connector location and FPC orientation
  • Panel supply requirements
  • Backlight-driver requirements
  • Active-area and outline position
  • Final mounting and bezel drawing
  • Optional-touch requirement
  • Touch controller and communications interface
  • Cover-lens and bonding plan
  • Operating and storage temperatures
  • Required luminance target
  • Sample quantity
  • Annual demand
  • Qualification and compliance requirements

Custom configurations are reviewed according to the requested touch structure, cable, cover lens, packaging and mechanical requirements. Sample and standard-module quantities are confirmed separately.

Application Scenarios

FAQ

About 13.3 Inch Full HD LCD Module

What must be checked before connecting a 30-pin eDP controller?

The complete eDP definition must be compared, not only the 30-pin connector count. Confirm the host link rate, lane configuration, native 1920 × 1080 timing, panel voltage, backlight requirements, pin assignment, connector location and FPC contact orientation. Submit both the host interface document and module pinout before designing the production cable.

Does matching 13.3-inch size and Full HD resolution guarantee replacement compatibility?

Matching size and resolution do not guarantee a direct replacement. This module has a 293.76 × 165.24 mm active area and a 305.35 × 187.82 × 2.70 mm outline, but another 13.3-inch panel may use a different connector position, mounting structure, eDP mapping or electrical requirement. Compare drawings, interface specifications and cable orientation before sample approval.

How should the optional capacitive-touch version be specified?

The touch-equipped version must be defined as a complete assembly. Provide the required touch interface, touch-point count, cover-lens dimensions, surface treatment, bonding preference, cable direction and controller-host requirements. The standard eDP connection covers the LCD image path and does not establish how the optional touch controller communicates with the host.

How does the 2.70 mm panel depth affect enclosure design?

The 2.70 mm figure describes the LCD module profile, not necessarily the final installed stack. Optional touch, cover glass, adhesive, connector clearance, cable bends and rear support can increase the required depth. Release the enclosure only after reviewing the approved LCD drawing and, where applicable, the separate touch-assembly drawing.

When should a different display configuration be selected?

A different product route should be considered when the system requires confirmed high brightness, direct HDMI input, a controller board, standard USB touch, specified optical performance or a finished enclosure. This module is primarily an eDP component for embedded integration, so additional functions require separate hardware or a more complete display assembly.

Need a custom solution or samples?

Submit Your Technical Requirements Submit the host eDP specification, full 30-pin assignment, panel and backlight power requirements, FPC orientation, enclosure drawing, touch requirement, cover-lens plan, lighting target, sample quantity and estimated annual demand. Engineering review covers eDP timing and pin compatibility, power and backlight requirements, optional-touch configuration, cable routing, active-area alignment, enclosure fit and available customization for the 13.3 Inch Full HD LCD Module.
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.