TM070RDG65-00 SFT WVGA HMI LCD 60-Pin FPC Tianma
Model P/N
Size
Resolution
Brightness
Viewing Angle
Connector Type
Operating Temp
Overall(mm)
tianma
TM070RDG65-00
Brand
Panel Size (inch)
Model P/N
Resolution
Brightness (nits)
Viewing Angle
Contrast Ratio
Response Time
Overall (mm)
Active Area (mm)
Refresh Rate
Display Colors
Panel Type
Connector Type
Operating Temp
Touchscreen Type
Storage Temp
Work Mode
Pixel Format
Designed For
Product Details
Product Overview
The TM070RDG65-00 SFT WVGA HMI LCD is a 7.0-inch Tianma a-Si TFT-LCD module intended for industrial display integration. Its native image is 800(RGB)×480 WVGA in a 15:9 format with RGB vertical-stripe pixels. The module uses SFT normally-black transmissive operation, supports 16.7 million colors and is specified for symmetric 85/85/85/85 typical viewing angles at CR≥10. Contrast ratio is 1000:1 typical, response time is 25 ms typical Tr+Td and refresh rate is 60 Hz.
The module includes a WLED backlight with an integrated LED driver, which changes the system boundary compared with a driverless display. A 60-pin FPC is identified, but the native display protocol, pin assignment, panel supply voltage, module dimensions, active area, brightness, touch configuration and environmental limits are not stated in the available model parameters. Those missing values should remain open verification items. A 60-pin connector and WVGA resolution are not enough to choose a controller or prove mechanical compatibility.
Three Core Buyer Value Propositions
SFT wide-view behavior supports multi-position industrial HMI viewing
The symmetric 85-degree viewing specification gives an integrator a strong panel-level starting point when an operator may view the screen from different positions. Tianma describes SFT as a wide-view display technology in its current product portfolio and uses it across industrial-oriented modules. That does not establish finished-system viewing performance by itself; front windows, air gaps, surface reflections and mounting angle still affect the operator experience and should be evaluated on the assembled HMI.
Integrated WLED driving reduces external illumination circuitry
The backlight is specified with an LED driver, so the host does not need to recreate the raw LED-string drive stage used by a driverless module. This can simplify the controller board and reduce one major integration variable. However, “with LED driver” does not define the required backlight supply, enable logic, dimming method, PWM range or power consumption. The released design still needs the model-specific electrical document for those values.
WVGA 800×480 provides a practical 7-inch HMI canvas
The 800×480 raster provides more horizontal working space than QVGA-class industrial displays while keeping a compact 7-inch format. It can support status dashboards, machine menus, process values and graphical controls without requiring a desktop-resolution graphics path. UI teams should still test the actual application at native resolution, especially where small text, alarms or trend plots must remain readable from the intended viewing distance.
Key Specifications at a Glance
| Parameter | Specification |
|---|---|
| Manufacturer / model | Tianma TM070RDG65-00 |
| Size / type | 7.0 inch a-Si TFT-LCD, LCM |
| Resolution | 800(RGB)×480 WVGA, 15:9 |
| Active area / overall dimensions | Not specified |
| Brightness | Not specified |
| Viewing angle | 85/85/85/85 typical at CR≥10; symmetric |
| Contrast / response | 1000:1 typical / 25 ms typical Tr+Td |
| Display mode / colors | SFT normally black transmissive / 16.7M colors |
| Pixel arrangement | RGB vertical stripe |
| Refresh rate | 60 Hz |
| Connection | 60-pin FPC; native signal protocol not specified |
| Panel input | Not specified |
| Backlight | WLED with integrated LED driver |
| Touch | Not specified |
| Temperature | Not specified |
| Designed for | Industrial |
What does the 60-pin FPC tell the controller designer?
The TM070RDG65-00 SFT WVGA HMI LCD is identified with a 60-pin FPC, but connector count is not a protocol definition. Before a controller board or cable is released, obtain the exact Tianma pin map and timing table to identify the display signaling method, pixel-data organization, clocking, sync/control signals, grounds, panel power contacts and backlight-control pins. A 60-pin FPC from another 7-inch WVGA module may physically fit while using a different electrical assignment.
Tianma’s industrial product family includes modules using interfaces such as LVDS and other embedded display connections, which reinforces the need to qualify each model from its own documentation (Tianma industrial display solutions). Do not borrow an interface type or voltage from another 7-inch Tianma panel solely because the size, resolution or SFT technology is similar.
Unknown protocol means controller selection must remain open
Until the native protocol is confirmed, it is premature to select a controller based only on WVGA output capability. An HDMI-to-LCD board, MCU RGB interface or LVDS controller could each be inappropriate if the panel-side signaling does not match. Procurement should request the model datasheet before the PCB design is frozen, and engineering should retain the exact approved controller firmware and cable revision after prototype qualification.
How should the integrated LED driver be handled?
The integrated driver removes the need for a separate raw-LED current source, but the host still has to power and control the backlight correctly. The available specifications do not state backlight supply voltage, driver efficiency, current draw, dimming method, PWM frequency or enable logic. These values belong to the exact module electrical specification and should not be inferred from the 7-inch size or from another SFT display.
During validation, exercise minimum and maximum brightness settings, repeated starts, long-duration operation and the intended dimming range. Measure the panel and enclosure temperature after thermal equilibrium. If the HMI requires night dimming, low-flicker imaging, camera compatibility or a minimum luminance, define those as system requirements and verify them with the production driver-control implementation. The presence of an integrated LED driver does not prove any particular dimming performance.
Why does SFT wide viewing matter in an industrial HMI?
The 85/85/85/85 typical viewing specification and symmetric direction are valuable where an operator may approach a machine from the side or where the panel is mounted above or below the primary eye line. Tianma has publicly described SFT as a wide-view technology in its display portfolio, including large automotive demonstrations (Tianma SFT wide-view example). That technology context is relevant, but it does not make this industrial model automotive qualified.
Viewing-angle numbers are not a substitute for front-stack testing
Cover windows, protective films, air gaps, anti-glare treatment and enclosure geometry can change the visible result. Because surface treatment is not specified for this model, the completed HMI should be checked under the actual ambient lighting and operator positions. If the equipment adds a touch sensor, cover glass or optical bonding, treat that as a separate project configuration; no touch function or bonding stack is established by the base module facts.
What should be done with the unspecified brightness and temperature data?
Brightness and environmental limits are material procurement and integration parameters, so their absence should remain visible rather than being filled with family-level assumptions. A related Tianma 7-inch industrial module may have documented luminance or wide-temperature operation, but that does not establish the same values for TM070RDG65-00. Ask for the current model specification before the application requirement is signed off.
If the target equipment needs a minimum luminance, define the threshold and measurement conditions in the RFQ. If it must operate below freezing or in a hot sealed cabinet, define the required operating and storage ranges and request evidence that the offered revision meets them. This approach converts missing specification fields into explicit qualification questions instead of silently creating unsupported “industrial grade” claims.
Mechanical qualification without outline dimensions
The 7-inch diagonal and 800×480 raster help identify the display class, but they are insufficient for enclosure design. Active area, overall width, height, thickness, connector location and mounting features are not specified in the current data. Final mechanical work should use the Tianma drawing and, for replacement projects, compare the original display and candidate drawing side by side.
Cable routing deserves particular attention because a 60-pin FPC can have a defined contact side, pitch, insertion orientation and bend constraint. An enclosure can accommodate the glass area yet still fail because the connector exits in another direction or the cable interferes with a bracket. Confirm these details before tooling, especially where the HMI is serviceable from the front or where cable replacement has to occur without removing other assemblies.
Industrial replacement and sourcing controls
The TM070RDG65-00 SFT WVGA HMI LCD should be evaluated as an exact-model component, not as a generic 7-inch WVGA panel. Match SFT normally-black operation, 85-degree viewing, 1000:1 contrast, response behavior, the 60-pin connector, integrated LED-driver control and all still-unverified electrical and mechanical details. A nearby 800×480 display can differ in protocol, voltage, timing, connector placement or optical performance.
A third-party sourcing reference currently lists the model as in production, but that should be treated only as a sourcing signal. Before a volume order, request Tianma or an authorized channel to confirm current revision, production status, traceability and any applicable PCN/EOL process. Stock counts from external marketplaces are not HS-LCD inventory and do not establish a guaranteed supply horizon or second-source arrangement.
Engineering Answers in Brief
TM070RDG65-00 is a 7-inch Tianma WVGA SFT module with 800×480 resolution, 60 Hz refresh and symmetric 85-degree viewing angles.
The module contains a WLED backlight with an integrated LED driver, but backlight supply and dimming-control requirements still require exact model documentation.
The 60-pin FPC identifies the connector form, not the display protocol; the current pinout and timing table are required before controller approval.
Brightness, temperature limits, module dimensions, panel voltage and touch configuration are not specified and should remain explicit RFQ verification items.
Procurement Checklist
- Specify Tianma TM070RDG65-00 exactly and confirm the offered revision.
- Obtain the current 60-pin FPC assignment, native interface timing and panel power requirements.
- Request the complete mechanical drawing with active area, outline, thickness and connector location.
- Confirm backlight-driver supply, enable and dimming-control requirements.
- Define required luminance and environmental limits instead of importing values from another 7-inch model.
- Validate native 800×480 at 60 Hz using the released controller, cable and firmware.
- Test viewing from the actual operator positions with the final protective/front stack.
- Reconfirm lifecycle, traceability and PCN/EOL expectations before volume purchasing.
The TM070RDG65-00 SFT WVGA HMI LCD offers a useful industrial display baseline through its WVGA resolution, SFT wide-view operation and integrated WLED driver. Production approval should remain conditional on closing the missing protocol, voltage, mechanical, luminance, environmental and touch details with current Tianma documentation and verifying the complete HMI assembly.
Recommended: Same Size
(7")
Applications & Value of LCD Panel
- Fast sourcing with in-stock panels & cross-reference alternatives
- Stable supply chain with long-term availability
- Engineering-level support from panel to integration
- Custom solutions: cable, touch & optical bonding
- Strict quality control with IQC / OQC / aging test
- Full traceability system for quality assurance
- Complete technical documentation & drawings
- Compliance support: RoHS & certification files