21.5 Inch High Brightness Industrial Touch Display for Production HMI

Product Gallery
Key Specs

Model P/N

HS01Q215TC-V1

Size

21.5″

Resolution

1920×1080

Brightness

1000 (Typ.)(cd/m²)

Viewing Angle

80/80/80/80

Connector Type

LVDS

Operating Temp

-10 ~
60 °C

Overall(mm)

505.6(W)×
302.2(H)×
15.62(D)
Upgrade Options (OEM/ODM)

huisoar

HS01Q215TC-V1

General Features

Brand

huisoar

Panel Size (inch)

21.5"

Model P/N

HS01Q215TC-V1

Resolution

1920×1080

Brightness (nits)

1000 cd/m² (Typ.)

Viewing Angle

80/80/80/80

Contrast Ratio

1000:1

Response Time

3–6ms

Overall (mm)

505.6(W)×
302.2(H) ×
15.62(D) mm

Active Area (mm)

476.64(W)x268.11(H) mm

Refresh Rate

60Hz

Display Colors

262K

Panel Type

tft-lcd, lcm

Connector Type

LVDS

Surface Treatment

Anti-glare Coating(Customizable with Anti-fingerprint)

Operating Temp

-10 ~
60 °C

Touchscreen Type

Projected-Capacitive(PCAP)touch

Storage Temp

−20°C to +70°C

Work Mode

Normally black, transmissive

Touch Interface

USB

Control Type

External video host/controller plus USB touch host

Operating Environment

Controlled industrial and high-ambient professional environments g(Typ./Max.)

Designed For

Industrial Automation, Industrial HMI, Outdoor Industrial Terminals, Medical Equipment,Production HMI, industrial workstations and control-room interfaces

21.5 Inch High Brightness Industrial Touch Display for Production HMI

This High Brightness Industrial Touch Display combines Full HD IPS imaging, 1000 cd/m² luminance and USB-connected PCAP touch for production workstations.

Product Summary

The 21.5-inch display assembly provides a large interactive workspace for production HMI consoles, industrial automation workstations, process-monitoring desks and operator-control systems. Its native 1920 × 1080 resolution supports detailed status pages, process graphics, camera views, alarms and operating controls on one screen.

Projected-capacitive touch adds direct interaction, while the USB touch connection allows the touch function to be linked separately to the system host. The 1000 cd/m² luminance provides a stronger optical starting point for brightly illuminated production areas and other high-ambient professional environments.

Key Specifications

ParameterValue
Display size21.5 inch
Native resolution1920 × 1080 pixels
Display formatFull HD, 16:9
Panel technologyIPS TFT-LCD
Luminance1000 cd/m²
Touch technologyProjected-capacitive touch
Touch interfaceUSB
Viewing-angle sequence80/80/80/80
BacklightLED backlight
Listed operating temperature−10°C to +60°C

Full HD Workspace for Production Interfaces

Native 1920 × 1080 Content

The interface should be developed at the native 1920 × 1080 raster. Native-resolution content helps preserve text edges, line thickness, icon detail and chart clarity without relying on controller scaling.

The Full HD workspace can accommodate:

  • machine-status dashboards
  • process trends
  • alarm lists
  • equipment controls
  • production counters
  • camera feeds
  • diagnostic pages
  • maintenance instructions
  • operating procedures

Large-Format Operator Layout

A 21.5-inch screen provides room for larger controls and clearer information grouping than compact embedded displays. Engineers can separate navigation, process data, warnings and live equipment status into defined zones rather than compressing all functions into one small interface.

The final UI should still consider operator viewing distance, touch-target size and installation height.

1000 cd/m² Optical Performance

High-Ambient Visibility

The 1000 cd/m² luminance specification supports evaluation in factories, production areas, operator stations and control rooms with strong ambient lighting.

Final visibility also depends on:

  • cover-glass transmission
  • surface reflections
  • air gaps
  • optical bonding
  • installation angle
  • enclosure shading
  • UI contrast
  • operating temperature
  • backlight control

The high luminance specification should be evaluated with the complete finished optical stack.

Finished Optical Stack Testing

A 1000 cd/m² panel does not automatically establish direct-sun readability. A cover lens or touch stack can introduce reflection and transmission losses that materially change the finished-system result.

Qualification should include:

  • ambient-light testing
  • reflected-image evaluation
  • dark-state visibility
  • cover-glass transmission
  • touch-layer optical loss
  • thermal luminance testing
  • day and night brightness settings

High Brightness Industrial Touch Display Integration

Separate Video and Touch Paths

The display image and touch data should be treated as separate system paths.

USB is identified as the touch interface. It carries touch-coordinate data to the host and does not replace the video connection needed to generate the image.

The host system must therefore provide:

  • a qualified video path
  • a USB touch connection
  • compatible touch drivers
  • stable power
  • grounding
  • cable routing
  • operating-system support

LVDS and HDMI Architecture Confirmation

The available product information refers to both LVDS and HDMI. These references must be reconciled before controller or cable selection.

The approved system documentation should identify:

  • native panel interface
  • controller-board input
  • number of LVDS channels
  • bit mapping
  • timing
  • connector assignment
  • panel voltage
  • backlight driver
  • HDMI input format, when present
  • USB touch-controller connection

Do not assume that HDMI is the native panel interface or that a generic LVDS cable will be compatible.

PCAP Touch Qualification

Projected-capacitive touch can support direct operator interaction, gesture-based navigation and software controls. The production configuration should be validated with the actual cover stack, controller and operating system.

Qualification should check:

  • supported touch-point count
  • USB descriptor
  • operating-system compatibility
  • coordinate orientation
  • edge accuracy
  • palm rejection
  • wet-finger behavior
  • glove requirements
  • touch latency
  • electromagnetic interference
  • grounding
  • cover-glass thickness
  • touch-controller firmware

The product title refers to 10-point capacitive touch, but the production release should be supported by a touch-controller specification and functional test report.

Thermal and Compliance Boundaries

The listed operating range is −10°C to +60°C. This range should be verified against the approved production datasheet before environmental testing.

The review should also confirm:

  • storage temperature
  • cold-start behavior
  • high-temperature luminance
  • touch operation across temperature
  • condensation conditions
  • humidity limits
  • backlight derating
  • controller-board thermal limits

REACH and RoHS compliance are listed, but project release should use the current declarations for the supplied display, touch panel, controller and cable configuration.

Recommended Applications

Production HMI Consoles

The Full HD screen can combine machine controls, status data, alarms and process graphics in one interactive interface.

Industrial Automation Workstations

The large touch area is suitable for operator stations that manage production lines, inspection processes or automated equipment.

Process-Monitoring Desks

The display can present real-time trends, equipment state, event logs and camera information in a centralized layout.

Control-Room Interfaces

The 21.5-inch workspace supports supervisory interfaces where operators need clear information grouping and direct touch input.

High-Ambient Professional Systems

The 1000 cd/m² luminance supports evaluation in brightly illuminated professional installations, subject to finished-stack optical validation.

Custom Integration Options

Project review can cover:

  • video controller selection
  • LVDS or HDMI architecture
  • USB touch integration
  • touch-controller tuning
  • cover glass
  • anti-glare or anti-reflection treatment
  • optical bonding
  • enclosure adaptation
  • mounting design
  • cable routing
  • connector orientation
  • branding
  • labeling
  • packaging

Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability and the requested specification. Samples and standard quantities are confirmed separately.

Procurement Checklist

Before sample or production approval, submit or confirm:

  • approved 1920 × 1080 timing
  • native panel video interface
  • controller-board input
  • LVDS channel count and bit mapping, when applicable
  • complete connector pin assignment
  • panel voltage
  • backlight voltage and current
  • power sequence
  • USB touch protocol
  • touch-controller model
  • 10-point touch test report
  • supported operating systems
  • module dimensions
  • mounting points
  • connector orientation
  • cable drawings
  • cover-glass stack
  • target ambient lighting
  • 1000 cd/m² luminance requirement
  • exact operating and storage ranges
  • REACH and RoHS documents
  • sample quantity
  • annual demand
  • production schedule
Application Scenarios

FAQ

About 21.5 Inch High Brightness Industrial Touch Display

What must be confirmed between the LVDS and HDMI listings?

The native panel interface and any controller-board input must be identified separately. The available information mentions both LVDS and HDMI, so the approved datasheet, controller specification and cable drawing are required before hardware release. A controller with HDMI input may still drive an internal LVDS panel, but that architecture cannot be assumed without documentation.

Which connection carries touch data?

USB is listed as the projected-capacitive touch interface. It carries touch-coordinate information to the host, while image data requires a separate video path. The operating system, touch controller, USB cable and coordinate orientation should be tested together with the sample.

Does 1000 cd/m² guarantee sunlight readability?

No. The 1000 cd/m² luminance improves visibility in high ambient light, but finished readability depends on cover-glass reflection, touch-layer transmission, optical bonding, installation angle and thermal behavior. Test the completed assembly under the actual target lighting.

What must be checked before approving 10-point touch?

Confirm the touch-controller specification, supported point count, USB protocol, operating-system driver, cover-glass thickness, edge accuracy and electromagnetic behavior. Functional testing should use the actual enclosure, grounding and cable layout.

Which environmental and compliance documents are required?

Obtain the approved operating and storage temperature specifications, current REACH and RoHS declarations, controller-board documentation and touch-panel material information. Compliance should apply to the supplied assembly rather than only one internal component.

Need a custom solution or samples?

Submit Your Project Requirements Information to submit: Send the approved datasheet and drawing, complete video-interface architecture, native timing, LVDS definition when applicable, controller-board specification, USB touch protocol, touch-controller data, power requirements, enclosure design, cover stack, operating environment, sample quantity and annual demand. Engineering review outcome: The review covers Full HD video compatibility, USB touch integration, PCAP qualification, optical performance, thermal limits, controller and cable matching, and mechanical integration of the High Brightness Industrial Touch Display.
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.