Freya Yang
+86 18318948097
+852 62667476
75 Inch Air Cooled Outdoor Display High Brightness Screen for Stadium Signage
Model P/N
Size
Resolution
Brightness
Viewing Angle
Connector Type
Operating Temp
Overall(mm)
huisoar
HS750HNX05-A01-BK
Brand
Panel Size (inch)
Model P/N
Resolution
Brightness (nits)
Viewing Angle
Contrast Ratio
Response Time
Overall (mm)
Active Area (mm)
Refresh Rate
Display Colors
Panel Type
Connector Type
Surface Treatment
Operating Temp
Touchscreen Type
Storage Temp
Work Mode
Control Type
Weight (g)
Operating Environment
Motherboard Type
Designed For
75 Inch Air Cooled Outdoor Display High Brightness Screen for Stadium Signage
This Air Cooled Outdoor Display pairs a 75-inch 4K screen with 2500 cd/m² luminance, IP66 protection, 5 mm anti-reflection IK10 glass, and temperature-triggered fan cooling for large public installations.
Product Summary
The Air Cooled Outdoor Display is a finished 75-inch digital signage system for stadium concourses, transit hubs, public-information zones, and other exposed installations that require a 3840 × 2160 image, 2500 cd/m² luminance, and controlled heat removal. Its IP66 enclosure, 5 mm front anti-reflection IK10 glass, automatic brightness adjustment, and automatic fan cooling above 35°C provide a defined outdoor platform rather than an open panel that still needs a separate cabinet.
The fan-control specification activates automatic cooling above 35°C.
IP66 protection can be compromised by unapproved cable entries or enclosure changes.
Optional Android, network, and touch hardware are configuration choices rather than standard inclusions.
Key Specifications at a Glance
| Item | Confirmed value |
|---|---|
| Screen size | 75 inches |
| Resolution | 3840 × 2160 pixels |
| Display area | 1649.66 × 927.94 mm |
| Luminance | 2500 cd/m² |
| Aspect ratio | 16:9 |
| Contrast ratio | 1200:1 |
| Response time | 8 ms typical, Tr/Td |
| Viewing data | 89/89/89/89° minimum at CR ≥ 10; directional order requires confirmation |
| Display colors | 16.7 million colors |
| Front protection | 5 mm anti-reflection glass, IK10 |
| Ingress protection | IP66 |
| Cooling system | Automatic fan cooling above 35°C |
| Brightness control | Automatic adjustment through a light sensor |
| Backlight reference | LED backlight; listed BL MTBF of 50,000 hours |
| Speakers | 5 W × 2 |
| Input power | AC 100–240 V |
| System power | Less than 800 W |
| Enclosure size | 1730.7 × 1009 × 107 mm |
| Mounting | 600 × 800 mm, four M8 points, 8 mm maximum thread depth |
| Operating temperature | −20°C to +70°C |
| Storage temperature | −30°C to +80°C |
The standard optical, mechanical, environmental, cooling, and power values are defined in the product specification.
4K Visibility for Large Public Displays
Native UHD Content Planning
The 3840 × 2160 raster supports promotional media, passenger information, event schedules, wayfinding, and mixed text-and-video layouts. Media players and content-management systems should deliver approved 4K output at the required orientation and scaling mode. Low-resolution creative assets still require separate visual testing.
2500 cd/m² Optical Boundary
The specified luminance is 2500 cd/m². Final readability also depends on solar orientation, glass reflections, viewing distance, content contrast, and automatic brightness-control behavior. Evaluate the complete screen and glass stack at the installation site rather than treating luminance alone as a universal sunlight-readability guarantee.
Anti-Reflection and Impact Protection
The 5 mm front glass combines anti-reflection treatment with an IK10 impact rating. Any change to glass thickness, coating, bonding, opening geometry, or touch stack requires renewed optical and mechanical review because it can alter transmission, reflection, sealing, and thermal behavior.
Air Cooled Outdoor Display Thermal Architecture
Temperature-Triggered Fan Cooling
The cooling system starts automatically above 35°C. This active approach is relevant to a 75-inch, 2500 cd/m² enclosure with system consumption below 800 W, where electronics losses and solar loading may exceed passive capacity. Qualification should cover airflow, internal temperature limits, noise expectations, service access, and mounting clearances. Outdoor-enclosure research also identifies solar load and internal air circulation as important thermal-design variables.
Power and Heat-Budget Review
AC 100–240 V input supports commercial installation, but the less-than-800-W rating still requires branch-circuit, surge-protection, cable, and heat-rejection planning. Use the ordered media-board, network, touch, speaker, and brightness configuration during the final electrical review.
IP66 Boundary and Service Access
IP66 applies to the approved enclosure. Cable glands, ventilation architecture, access doors, mounting penetrations, and field-installed connectors must preserve the tested sealing route. Service procedures should define how technicians access fans and electronics without damaging gaskets.
Media, Network, and Interaction Options
Android or External-Player Architecture
An Android 11 configuration with 4 GB RAM and 32 GB storage is optional. An external media player may be used when the ordered interface configuration provides the required connection. Select the architecture according to content-management software, security policy, remote-update needs, video formats, and service ownership.
Optional Signal and Network I/O
The configurable I/O list includes one HDMI port, one RJ45 port, two USB ports, and AC input. Wi-Fi, Ethernet, and 4G networking are optional. Final quotations and drawings should identify installed ports, sealing methods, cable directions, and remote-management scope.
Optional 10-Point Capacitive Touch
A 10-point capacitive touch option is available, but touch changes the front stack, controller, interface, bonding, bezel, and service plan. Interactive directories and public kiosks should verify touch operation through the specified glass under the intended temperature, moisture, and glove-use conditions.
Mechanical Integration and Mounting
The enclosure measures 1730.7 × 1009 × 107 mm and uses a 600 × 800 mm mounting pattern with four M8 points and an 8 mm maximum thread depth. The support structure must account for final system weight, wind load, orientation, service clearance, cable access, and center of gravity. Net weight remains unconfirmed, so the frame should not be released from dimensions alone.
The visible display area is 1649.66 × 927.94 mm. Graphic-safe areas, trim, and architectural openings should be checked against this visible area.
Application Fit and Configuration Boundaries
The Air Cooled Outdoor Display is suited to stadium signage, transit-hub information, public wayfinding, outdoor advertising, and institutional displays after optical, thermal, structural, electrical, and environmental review. The active cooling architecture addresses heat loads that may be difficult for a comparable passive system.
The standard configuration does not establish stainless-steel material, optical bonding, IP69K, DC 9–36 V input, 1500–5000-nit operation, medical suitability, or every advanced coating option. These capabilities require configuration-specific documentation.
Customization and Sample Planning
Project review can cover media architecture, optional Android, network hardware, touch integration, brightness control, front-glass treatment, cable-entry sealing, mounting, thermal design, enclosure material, branding, and packaging. Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability, and the requested specification. Sample and standard-display quantities are confirmed separately.
Procurement Checklist
Confirm the approved drawing; 3840 × 2160 content path; 2500 cd/m² target under actual site lighting; light-sensor behavior; fan start threshold and airflow path; IP66 documentation and sealing details; 5 mm anti-reflection IK10 glass; optional Android, network, I/O, and touch scope; AC 100–240 V supply; less-than-800-W budget; 1730.7 × 1009 × 107 mm enclosure fit; 600 × 800 mm mounting; final net weight; service clearance; operating schedule; sample criteria; quantity; and annual demand.


FAQ
About 75 Inch Air Cooled Outdoor Display High Brightness Screen
What thermal information is required before approving the installation?
How does fan cooling affect the maintenance plan?
Does IP66 remain valid after adding cables or changing the mount?
When should optional Android be selected instead of an external player?
What must be confirmed for optional touch?
Freya Yang