Freya Yang
+86 18318948097
+852 62667476
75 Inch UHD Sunlight Readable Signage LCD Panel for Transit Hubs
Model P/N
Size
Resolution
Brightness
Viewing Angle
Connector Type
Operating Temp
Overall(mm)
huisoar
HS750ENT-GD45
Brand
Panel Size (inch)
Model P/N
Resolution
Brightness (nits)
Viewing Angle
Contrast Ratio
Response Time
Overall (mm)
Active Area (mm)
Refresh Rate
Bezel Opening
Display Colors
Panel Type
Connector Type
Surface Treatment
Operating Temp
Touchscreen Type
Storage Temp
Work Mode
Pixel Format
Input Voltage (V)
Weight (g)
Operating Environment
Designed For
75 Inch UHD Sunlight Readable Signage LCD Panel for Transit Hubs
This 75-inch 4K IPS panel gives outdoor-signage builders a configurable high-luminance platform with anti-glare treatment and V-by-One connectivity.
Product Summary
The UHD Sunlight Readable Signage LCD Panel is a large-format a-Si TFT-LCD module for transport information, public advertising and smart-city display systems. Its native 3840 × 2160 resolution, RGBW vertical-stripe layout and 1649.66 × 927.936 mm active area provide a detailed visual canvas for timetable information, public notices, video advertising and other large-screen content.
The technical configuration includes IPS normally black transmissive operation, 89° viewing in each stated direction, 1200:1 typical contrast and an anti-glare surface with 3% haze and 2H hard coating. The listed brightness family spans 1000–5000 cd/m², so the exact ordered version must be fixed before optical, power and thermal release.
Key Specifications
| Parameter | Confirmed value |
|---|---|
| Panel size | 75 inches |
| Native resolution | 3840 × 2160 pixels |
| Pixel configuration | RGBW vertical stripe, 59 PPI |
| Active area | 1649.66 × 927.936 mm |
| View area | 1651.6 × 930 mm |
| Luminance family | 1000–5000 cd/m² typical; ordered version to be confirmed |
| Display mode | IPS, normally black, transmissive |
| Viewing angle | 89°/89°/89°/89° L/R/U/D at CR ≥ 10 |
| Contrast ratio | 1200:1 typical |
| Surface | Anti-glare, 3% haze, 2H hard coating |
| Response time | 8 ms typical, G-to-G |
| Colors | 1.07 billion, 10-bit, 69% NTSC |
| Backlight | WLED with LED driver |
| Listed backlight life | 50,000 hours |
| Refresh rate | 60 Hz standard |
| Interface | Eight-lane, 56-pin V-by-One |
| Panel voltage | 12.0 V typical |
| Panel weight | 27.6 kg typical / 30.5 kg maximum |
| Touch | No touch |
| Operating temperature | −20°C to +70°C |
| Storage temperature | −30°C to +80°C |
1000–5000 cd/m² Optical Version Planning
Confirm the Ordered Luminance Version
The listed range should be treated as a family of brightness configurations rather than a simultaneous operating range. The purchasing specification should identify the nominal luminance, allowed tolerance, test point, backlight condition and dimming requirements for the ordered GD45 revision.
A 1000 cd/m² version and a 5000 cd/m² version have materially different power, thermal and front-window implications. The brightness decision should therefore be completed before enclosure design, cooling release and sample approval.
Test the Completed Optical Stack
Panel luminance alone does not determine installed readability. Cover-glass transmission, internal reflection, bonding method, surface contamination, display orientation and ambient-light direction all affect the final image.
Qualification should use the selected panel version behind the planned front window. Test white timetable pages, dark video, brand graphics and warning messages at the required viewing distances and angles. High-brightness signage from established manufacturers also combines luminance with anti-reflection measures, environmental protection and thermal control rather than treating brightness as the only outdoor requirement.
Native UHD Content and RGBW Rendering
Validate 4K Timing and Content Scaling
The panel has a native 3840 × 2160 raster and RGBW vertical-stripe structure. The controller must produce an approved native timing and an image-processing path appropriate for the RGBW subpixel arrangement.
Confirm pixel clock, frame rate, blanking, color mapping, bit depth and scaling behavior with the approved timing document. Test thin text, one-pixel lines, high-contrast icons and diagonal graphics because these patterns reveal scaling or subpixel-rendering problems more clearly than video.
The listed standard refresh rate is 60 Hz. Optional MEMC processing may create smoother perceived motion, but it does not by itself establish native 120 Hz panel operation.
Integrating the UHD Sunlight Readable Signage LCD Panel
Qualify the 56-Pin V-by-One Connection
A matching 56-pin connector is not sufficient to prove compatibility. Verify the complete eight-lane assignment, connector orientation, lane order, link rate, control signals, grounding, voltage levels and cable construction.
The controller and cable should be tested together at native UHD timing. Review cable length, shielding, bend radius and routing near backlight or power wiring before the mechanical design is frozen.
Separate the 12.0 V Rail from Backlight Requirements
The listed 12.0 V value identifies the typical panel driving voltage. It does not provide the complete WLED electrical specification.
Obtain the panel current, backlight voltage and current, enable and dimming logic, driver architecture, startup sequence and protection requirements. Power and thermal calculations should use the approved ordered-luminance version rather than assumptions derived from another 75-inch model.
Mechanical and Environmental Release
Distinguish Active Area, View Area and Full Outline
The 1649.66 × 927.936 mm active area defines the image-producing region. The 1651.6 × 930 mm view area provides a cabinet-window reference. Neither value replaces the complete panel outline and support drawing.
Mechanical release requires total width, height and depth; mounting points; keep-out zones; connector clearance; edge loading limits; panel flatness; handling points and approved support locations.
Design for Panel Load and Solar Heat
The listed panel weight is 27.6 kg typical and 30.5 kg maximum. The enclosure must support that mass without twisting the glass or loading unsupported edges.
Outdoor systems must also manage backlight heat, controller heat and solar loading. Validate airflow, heat exchangers or other cooling methods under the final enclosure and orientation. Outdoor-electronics research and commercial product guidance both identify solar loading and cooling-path design as critical reliability factors.
The −20°C to +70°C panel range is an operating boundary, not an ingress-protection rating. Rain, dust, condensation, drainage, corrosion, impact protection and service-door sealing require a separately qualified enclosure.
Application Fit
An UHD Sunlight Readable Signage LCD Panel can be evaluated for transport-hub information boards, outdoor advertising structures, public-information displays and smart-city signage. The large active area supports long-distance messaging, while native UHD resolution provides room for detailed maps, timetable grids and multi-zone layouts.
The standard panel is non-touch. Interactive kiosk projects require a separately approved touch sensor, controller, cover lens, bonding stack and mechanical tolerance plan.
Customization and Procurement
Project evaluation may cover the ordered luminance version, front glass, optical bonding, AR/AG/AF treatments, enclosure materials, IP-rated sealing, impact protection, alternate connectors, control electronics, sensors, branding and mounting. These options become product specifications only after they are included in an approved configuration.
Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability and the requested specification. Samples and standard-panel quantities are confirmed separately.
Procurement Checklist
- Assigned HS750ENT-GD45 and RS750ENT-GD45 revision
- Approved nominal luminance and tolerance
- Native 3840 × 2160 timing at 60 Hz
- RGBW rendering and scaling plan
- Complete eight-lane, 56-pin V-by-One assignment
- Connector orientation and cable drawing
- 12.0 V panel-rail requirements
- WLED voltage, current, enable and dimming data
- Power sequence and protection requirements
- 1649.66 × 927.936 mm active area
- 1651.6 × 930 mm view area
- Complete outer and support drawing
- 27.6 kg typical / 30.5 kg maximum structural load
- Front-window transmission and reflection targets
- Bonding and surface-treatment requirements
- Cooling and solar-load plan
- Required enclosure IP and impact grade
- Standard non-touch or custom touch route
- Sample acceptance criteria
- Quantity and annual demand


FAQ
About 75 Inch UHD Sunlight Readable Signage LCD Panel
What must be confirmed before selecting a luminance version?
How is 56-pin V-by-One compatibility verified?
Does optional MEMC make the panel a native 120 Hz display?
Does the temperature range prove outdoor weather resistance?
What mechanical information is still required before cabinet release?