Key Specs

Model P/N

HS480-SBL-FHD-200

Size

48″

Resolution

1920×317

Brightness

600 (Typ.)(cd/m²)

Viewing Angle

89/89/89/89 raw sequence

Connector Type

51-pin LVDS

Operating Temp

0 ~
50 °C

Overall(mm)

1238.5(W)×
232.5(H)×
26.5(D)
Upgrade Options (OEM/ODM)

huisoar

HS480-SBL-FHD-200

General Features

Brand

huisoar

Panel Size (inch)

48"

Model P/N

HS480-SBL-FHD-200

Resolution

1920×317

Brightness (nits)

600 cd/m² (Typ.)

Viewing Angle

89/89/89/89 raw sequence

Contrast Ratio

5000:1 (Typ.)

Response Time

18ms

Overall (mm)

1238.5(W)×
232.5(H) ×
26.5(D) mm

Active Area (mm)

1209.60 mm × 200.00 mm

Refresh Rate

60Hz

Display Colors

1.07B colors

Panel Type

tft-lcd, lcm

Connector Type

51-pin LVDS

Operating Temp

0 ~
50 °C

Touchscreen Type

Optional customization

Storage Temp

−20°C to +60°C

Work Mode

Normally black

Control Type

External LVDS host or qualified controller board

Operating Environment

Indoor and controlled public-space installations g(Typ./Max.)

Motherboard Type

LVDS-capable signage or embedded controller g(Typ./Max.)

Designed For

Public transport information displays, passenger information systems, railway and metro station displays, platform and concourse signage, onboard train and bus displays, real-time arrival and departure boards, strip display systems, bar-type digital signage, wayfinding screens, transit advertising displays, commercial signage, and OEM/ODM wide-format passenger display systems.

48 Inch Transit Signage LCD Module for Passenger Displays

This long-format 48-inch panel combines a native 1920 × 317 canvas, 600-nit luminance and 51-pin LVDS integration for passenger-information systems.

Product Summary

The Transit Signage LCD Module provides a wide, shallow display area for railway information bands, station guidance screens and commercial-signage systems that cannot accommodate a conventional monitor format. Its native 1920 × 317 raster supports route names, stop sequences, timing data, service messages and advertising content across a continuous horizontal canvas.

The module combines a normally black VA TFT LCD structure, 600-nit luminance, a 5000:1 typical contrast ratio and 1.07B color support. It uses a 51-pin LVDS connection and operates at 60 Hz. The standard configuration is non-touch.

Key Specifications

ParameterValue
Size48 inch
Resolution1920 × 317 pixels
Panel typeVA a-Si TFT LCD
Display modeNormally black
Luminance600 nits
Contrast ratio5000:1 typical
Viewing data89/89/89/89 raw sequence
Colors1.07B
Refresh rate60 Hz
Interface51-pin LVDS
Active area1209.60 × 200.00 mm
Outline1238.5 × 232.5 × 26.5 mm
BacklightWLED
TouchNon-touch
Operating temperature0°C to +50°C
Storage temperature−20°C to +60°C

Native 1920 × 317 Content Design

Route and Passenger-Information Layouts

The 1920 × 317 raster is designed for information that extends horizontally rather than vertically. Suitable layouts include:

  • station and stop sequences
  • route-direction arrows
  • departure and arrival timing
  • service notices
  • platform guidance
  • transfer information
  • warning bands
  • commercial advertising zones

The display can divide the canvas into fixed content regions so route information remains visible while service messages or promotional graphics update independently.

Native-Raster Content Preparation

The 1920 × 317 raster should be driven natively to preserve route text and long-format graphics.

A host designed only for common 16:9 resolutions may scale, crop or letterbox the content. Software and controller teams should verify:

  • native output timing
  • aspect-ratio handling
  • text size
  • content-zone width
  • image scaling
  • animation speed
  • multilingual character support
  • safe margins near the bezel

The UI should be approved on a physical sample because long viewing distances and passenger movement affect practical text sizing.

Optical Performance for Controlled Public Spaces

600-Nit Luminance Boundary

The standard panel is specified at 600 nits. This level supports many indoor transit areas, station corridors and controlled public spaces where ambient light exceeds ordinary office conditions.

A 600-nit panel does not by itself establish outdoor readability after cover glass and installation conditions are applied.

Protective glass, air gaps, optical adhesive, reflections, lighting direction and installation angle can reduce finished-system contrast. Outdoor or direct-sunlight projects require a separate optical and environmental review.

VA Contrast and Viewing Data

The panel uses normally black VA operation with a 5000:1 typical contrast ratio. This can improve visual separation between dark backgrounds, white route text, colored status elements and warning graphics.

The viewing-angle data is listed as 89/89/89/89. The directional order is not explicitly identified, so the values should remain as an unassigned raw sequence until the approved specification confirms orientation.

Wide-angle performance is useful in passenger areas because viewers may approach from different positions, but front glass and mounting geometry still affect the final result.

51-Pin LVDS Integration

Timing, Mapping and Pinout Qualification

A 51-pin LVDS connector does not guarantee timing, voltage, bit-depth or pin compatibility with another 51-pin panel.

Before selecting a controller or releasing a cable, confirm:

  • native 1920 × 317 timing
  • LVDS channel count
  • bit configuration
  • signal mapping
  • signal voltage
  • complete 51-pin assignment
  • connector pitch
  • contact side
  • connector orientation
  • panel power
  • backlight power and control
  • cable length and routing

The controller must support the unusual raster directly or provide verified scaling without distorting passenger-information content.

Non-LVDS Sources Require Conversion

HDMI, DisplayPort, eDP, MIPI DSI, USB and parallel RGB sources cannot connect directly to the panel unless a controller converts the input into the required LVDS timing.

A controller-board review should cover:

  • accepted input format
  • native 1920 × 317 output
  • refresh-rate support
  • LVDS mapping
  • color-depth handling
  • panel and backlight power
  • startup behavior
  • thermal conditions
  • cable layout

Resolution alone is not enough to prove compatibility.

Transit Signage LCD Module Mechanical Planning

Active Area and Visible Opening

The active display area is 1209.60 × 200.00 mm. This should control:

  • visible enclosure opening
  • content-safe margins
  • front-glass window
  • bezel printing
  • module alignment
  • passenger viewing distance

Important text and route markers should remain inside the final approved opening after frame overlap and assembly tolerances are considered.

Enclosure Depth and Mounting Support

The overall module measures 1238.5 × 232.5 × 26.5 mm. Its length creates different mechanical requirements from a smaller conventional panel.

The enclosure review should include:

  • distributed mounting support
  • frame straightness
  • torsional control
  • rear clearance
  • cable exit
  • connector access
  • thermal airflow
  • front-glass support
  • transport and installation handling

Long modules should not be supported only at the ends unless the approved mechanical design explicitly permits that arrangement.

60 Hz and Color-Handling Requirements

The panel is listed for 60 Hz operation and 1.07B display colors.

The complete host path must support the required timing and color configuration. A controller that outputs the correct pixel dimensions but uses an incompatible refresh rate, LVDS mapping or color-depth mode may produce no image, unstable operation or incorrect colors.

Confirm:

  • native 60 Hz timing
  • graphics-controller output
  • LVDS bit configuration
  • dithering or color-processing method
  • cable signal integrity
  • controller thermal performance

The 1.07B-color specification does not independently establish color calibration, gamut or professional color accuracy.

Non-Touch Application Architecture

The standard module is non-touch. This suits passive information systems where viewers read content but do not interact directly with the screen.

Potential applications include:

  • rail and metro passenger information
  • station route guidance
  • public-transport service notices
  • digital-signage headers
  • commercial advertising bands
  • retail information strips
  • building wayfinding
  • equipment status banners

A non-touch design avoids touch-controller integration and additional optical layers. Projects requiring interaction need a separately defined touch sensor, controller, cover lens and mechanical stack.

Custom Integration Options

Project review may include:

  • 51-pin LVDS controller matching
  • custom LVDS cable
  • interface and timing verification
  • brightness review
  • cover-glass sizing
  • anti-glare or anti-reflection treatment
  • optical bonding
  • enclosure adaptation
  • long-panel mounting support
  • logo and graphic printing
  • optional touch development
  • packaging and labeling

Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability and the requested specification. Sample and standard-module quantities are confirmed separately.

Procurement Checklist

Before requesting samples or production approval, submit or confirm:

  • native 1920 × 317 timing
  • LVDS channel count and mapping
  • bit configuration
  • signal voltage
  • complete 51-pin assignment
  • connector pitch and orientation
  • panel and backlight power requirements
  • controller-board model
  • 60 Hz output support
  • color-path requirements
  • active-area and outline drawing
  • mounting-support design
  • front-glass stack
  • 600-nit lighting environment
  • touch or non-touch requirement
  • operating temperature
  • original manufacturer model
  • sample quantity
  • annual demand

Sample approval should precede controller release, cable manufacture, front-glass tooling and enclosure production.

Application Scenarios

FAQ

About 48 Inch Transit Signage LCD Module

What must be checked before connecting a 51-pin LVDS controller?

The controller must match the complete electrical definition, not only the connector count. Confirm native 1920 × 317 timing, LVDS channel and bit configuration, signal voltage, full pin assignment, panel power and backlight controls. The controller, cable and approved panel specification should be compared before applying power.

How should content be prepared for the 1920 × 317 display?

Content should be created for the native long-format raster rather than cropped from a standard 16:9 layout. Divide the canvas into route, timing, notice and advertising zones, and validate text size at the intended passenger viewing distance. Keep critical information inside the approved visible opening based on the 1209.60 × 200.00 mm active area.

Is 600-nit luminance sufficient behind cover glass?

The 600-nit configuration can support controlled indoor transit areas, but finished visibility depends on the optical stack. Glass, coatings, air gaps, reflections and installation angle may reduce contrast. Submit the front-glass construction and lighting environment so a representative assembly can be evaluated before release.

Which dimensions should control enclosure release?

Use the approved drawing based on the 1238.5 × 232.5 × 26.5 mm module outline and the 1209.60 × 200.00 mm active area. The review must also cover distributed mounting support, connector access, cable routing, frame straightness and front-glass loading before tooling is released.

When should the non-touch configuration be selected?

The non-touch module is appropriate for passive passenger information, route guidance and advertising systems. It avoids the added optical and electrical complexity of a touch layer. Projects requiring direct interaction should separately define the touch technology, controller interface, cover lens, bonding method and finished module thickness.

Need a custom solution or samples?

Submit Your Technical Requirements Information to submit: Provide native 1920 × 317 timing, LVDS mapping and full 51-pin assignment, controller-board details, panel and backlight power requirements, enclosure drawing, mounting plan, front-glass stack, lighting target, sample quantity and annual demand. Engineering review outcome: The review covers LVDS compatibility, strip-content mapping, 60 Hz and color-path support, optical performance, long-module mechanics and customization for the Transit Signage LCD Module.

Recommended: Same Size

(48")

Alternatives
No data was found
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.