75 Inch Air Cooled Outdoor Display High Brightness Screen for Stadium Signage

Product Gallery
Key Specs

Model P/N

HS750HNX05-A01-BK

Size

75.0″

Resolution

3840×2160

Brightness

2500 (Typ.)(cd/m²)

Viewing Angle

89/89/89/89° minimum at CR ≥ 10

Connector Type

V-BY-ONE

Operating Temp

-20 ~
50 °C

Overall(mm)

1730.7(W)×
1009(H)×
72(D)
Upgrade Options (OEM/ODM)

huisoar

HS750HNX05-A01-BK

General Features

Brand

huisoar

Panel Size (inch)

75.0"

Model P/N

HS750HNX05-A01-BK

Resolution

3840×2160

Brightness (nits)

2500 cd/m² (Typ.)

Viewing Angle

89/89/89/89° minimum at CR ≥ 10

Contrast Ratio

1200:1

Response Time

8 ms typical, Tr/Td

Overall (mm)

1730.7(W)×
1009(H) ×
72(D) mm

Active Area (mm)

1649.66 × 927.94 mm

Refresh Rate

70Hz

Display Colors

16.7 million colors

Panel Type

tft-lcd, lcm

Connector Type

V-BY-ONE

Surface Treatment

5mm AR Anti-Reflection Glass, IK10

Operating Temp

-20 ~
50 °C

Touchscreen Type

Optional (Capacitive, 10 Points)

Storage Temp

−30°C to +80°C

Work Mode

IPS, Normally Black, Transmissive

Control Type

Optional Android 11 or external media-player architecture

Weight (g)

-20 g(Typ./Max.)

Operating Environment

IP66 outdoor enclosure for bright public-facing installations g(Typ./Max.)

Motherboard Type

Optional Android 11 with 4 GB RAM and 32 GB storage g(Typ./Max.)

Designed For

Outdoor Signage, Advertising, Stadium screens, transit-hub displays, outdoor digital signage, and public-information installations

75 Inch Air Cooled Outdoor Display High Brightness Screen for Stadium Signage

This Air Cooled Outdoor Display pairs a 75-inch 4K screen with 2500 cd/m² luminance, IP66 protection, 5 mm anti-reflection IK10 glass, and temperature-triggered fan cooling for large public installations.

Product Summary

The Air Cooled Outdoor Display is a finished 75-inch digital signage system for stadium concourses, transit hubs, public-information zones, and other exposed installations that require a 3840 × 2160 image, 2500 cd/m² luminance, and controlled heat removal. Its IP66 enclosure, 5 mm front anti-reflection IK10 glass, automatic brightness adjustment, and automatic fan cooling above 35°C provide a defined outdoor platform rather than an open panel that still needs a separate cabinet.

The fan-control specification activates automatic cooling above 35°C.

IP66 protection can be compromised by unapproved cable entries or enclosure changes.

Optional Android, network, and touch hardware are configuration choices rather than standard inclusions.

Key Specifications at a Glance

ItemConfirmed value
Screen size75 inches
Resolution3840 × 2160 pixels
Display area1649.66 × 927.94 mm
Luminance2500 cd/m²
Aspect ratio16:9
Contrast ratio1200:1
Response time8 ms typical, Tr/Td
Viewing data89/89/89/89° minimum at CR ≥ 10; directional order requires confirmation
Display colors16.7 million colors
Front protection5 mm anti-reflection glass, IK10
Ingress protectionIP66
Cooling systemAutomatic fan cooling above 35°C
Brightness controlAutomatic adjustment through a light sensor
Backlight referenceLED backlight; listed BL MTBF of 50,000 hours
Speakers5 W × 2
Input powerAC 100–240 V
System powerLess than 800 W
Enclosure size1730.7 × 1009 × 107 mm
Mounting600 × 800 mm, four M8 points, 8 mm maximum thread depth
Operating temperature−20°C to +70°C
Storage temperature−30°C to +80°C

The standard optical, mechanical, environmental, cooling, and power values are defined in the product specification.

4K Visibility for Large Public Displays

Native UHD Content Planning

The 3840 × 2160 raster supports promotional media, passenger information, event schedules, wayfinding, and mixed text-and-video layouts. Media players and content-management systems should deliver approved 4K output at the required orientation and scaling mode. Low-resolution creative assets still require separate visual testing.

2500 cd/m² Optical Boundary

The specified luminance is 2500 cd/m². Final readability also depends on solar orientation, glass reflections, viewing distance, content contrast, and automatic brightness-control behavior. Evaluate the complete screen and glass stack at the installation site rather than treating luminance alone as a universal sunlight-readability guarantee.

Anti-Reflection and Impact Protection

The 5 mm front glass combines anti-reflection treatment with an IK10 impact rating. Any change to glass thickness, coating, bonding, opening geometry, or touch stack requires renewed optical and mechanical review because it can alter transmission, reflection, sealing, and thermal behavior.

Air Cooled Outdoor Display Thermal Architecture

Temperature-Triggered Fan Cooling

The cooling system starts automatically above 35°C. This active approach is relevant to a 75-inch, 2500 cd/m² enclosure with system consumption below 800 W, where electronics losses and solar loading may exceed passive capacity. Qualification should cover airflow, internal temperature limits, noise expectations, service access, and mounting clearances. Outdoor-enclosure research also identifies solar load and internal air circulation as important thermal-design variables.

Power and Heat-Budget Review

AC 100–240 V input supports commercial installation, but the less-than-800-W rating still requires branch-circuit, surge-protection, cable, and heat-rejection planning. Use the ordered media-board, network, touch, speaker, and brightness configuration during the final electrical review.

IP66 Boundary and Service Access

IP66 applies to the approved enclosure. Cable glands, ventilation architecture, access doors, mounting penetrations, and field-installed connectors must preserve the tested sealing route. Service procedures should define how technicians access fans and electronics without damaging gaskets.

Media, Network, and Interaction Options

Android or External-Player Architecture

An Android 11 configuration with 4 GB RAM and 32 GB storage is optional. An external media player may be used when the ordered interface configuration provides the required connection. Select the architecture according to content-management software, security policy, remote-update needs, video formats, and service ownership.

Optional Signal and Network I/O

The configurable I/O list includes one HDMI port, one RJ45 port, two USB ports, and AC input. Wi-Fi, Ethernet, and 4G networking are optional. Final quotations and drawings should identify installed ports, sealing methods, cable directions, and remote-management scope.

Optional 10-Point Capacitive Touch

A 10-point capacitive touch option is available, but touch changes the front stack, controller, interface, bonding, bezel, and service plan. Interactive directories and public kiosks should verify touch operation through the specified glass under the intended temperature, moisture, and glove-use conditions.

Mechanical Integration and Mounting

The enclosure measures 1730.7 × 1009 × 107 mm and uses a 600 × 800 mm mounting pattern with four M8 points and an 8 mm maximum thread depth. The support structure must account for final system weight, wind load, orientation, service clearance, cable access, and center of gravity. Net weight remains unconfirmed, so the frame should not be released from dimensions alone.

The visible display area is 1649.66 × 927.94 mm. Graphic-safe areas, trim, and architectural openings should be checked against this visible area.

Application Fit and Configuration Boundaries

The Air Cooled Outdoor Display is suited to stadium signage, transit-hub information, public wayfinding, outdoor advertising, and institutional displays after optical, thermal, structural, electrical, and environmental review. The active cooling architecture addresses heat loads that may be difficult for a comparable passive system.

The standard configuration does not establish stainless-steel material, optical bonding, IP69K, DC 9–36 V input, 1500–5000-nit operation, medical suitability, or every advanced coating option. These capabilities require configuration-specific documentation.

Customization and Sample Planning

Project review can cover media architecture, optional Android, network hardware, touch integration, brightness control, front-glass treatment, cable-entry sealing, mounting, thermal design, enclosure material, branding, and packaging. Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability, and the requested specification. Sample and standard-display quantities are confirmed separately.

Procurement Checklist

Confirm the approved drawing; 3840 × 2160 content path; 2500 cd/m² target under actual site lighting; light-sensor behavior; fan start threshold and airflow path; IP66 documentation and sealing details; 5 mm anti-reflection IK10 glass; optional Android, network, I/O, and touch scope; AC 100–240 V supply; less-than-800-W budget; 1730.7 × 1009 × 107 mm enclosure fit; 600 × 800 mm mounting; final net weight; service clearance; operating schedule; sample criteria; quantity; and annual demand.

Application Scenarios

FAQ

About 75 Inch Air Cooled Outdoor Display High Brightness Screen

What thermal information is required before approving the installation?

Provide solar orientation, maximum ambient temperature, operating schedule, enclosure color, mounting clearance, airflow path, fan behavior above 35°C, and the less-than-800-W power limit. These inputs determine whether the active cooling arrangement can keep the panel and electronics within approved temperatures. Include the site layout and mounting drawing before structural or electrical release.

How does fan cooling affect the maintenance plan?

Confirm fan quantity, airflow direction, expected life, monitoring method, access procedure, and whether filters are used. The enclosure must be opened and resealed according to the approved IP66 design. Inspection intervals should reflect dust, traffic pollution, salt exposure, and operating hours.

Does IP66 remain valid after adding cables or changing the mount?

Not automatically. New cable glands, field-drilled holes, access panels, connector substitutions, or mounting penetrations can create ingress paths. Submit external connections and mechanical changes for review, and require drawings that show gasket interfaces, gland ratings, fastener treatment, and service access.

When should optional Android be selected instead of an external player?

Select optional Android 11 when the approved content-management application, update policy, storage requirement, and network environment fit the 4 GB RAM and 32 GB storage configuration. Use an external player for another operating system, specialized decoding, enterprise security, or an established signage platform. Confirm the installed interfaces before finalizing either route.

What must be confirmed for optional touch?

Verify the 10-point capacitive controller, host interface, cover-glass stack, bonding, bezel geometry, accuracy, moisture behavior, glove requirement, and temperature performance. The 5 mm front glass and IP66 enclosure make touch a system-level option. Test a fully assembled sample with the intended interface and mounting orientation.

Need a custom solution or samples?

Request a Technical Review Submit installation orientation, solar exposure, ambient-temperature range, operating schedule, 4K content and player architecture, required network and touch options, AC supply, mounting drawing, cable-entry plan, service-access requirements, sample quantity, and annual demand for the Air Cooled Outdoor Display. Engineering review covers optical visibility, active cooling, IP66 sealing, media and network architecture, touch integration, power, mounting, structural fit, and configuration-specific documentation.

Recommended: Same Size

(75.0")

Alternatives
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.