8 Inch RGB Industrial HMI Touch Display Module for Control Panels

Product Gallery
Key Specs

Model P/N

HS080PRT700

Size

8.0″

Resolution

800×600

Brightness

380 (Typ.)(cd/m²)

Viewing Angle

Full-angle visibility

Connector Type

RGB interface

Operating Temp

-20 ~
70 °C

Overall(mm)

183(W)×
141(H)×
3.5(D)
Upgrade Options (OEM/ODM)

huisoar

HS080PRT700

General Features

Brand

huisoar

Panel Size (inch)

8.0"

Model P/N

HS080PRT700

Resolution

800×600

Brightness (nits)

380 cd/m² (Typ.)

Viewing Angle

Full-angle visibility

Contrast Ratio

500:1

Response Time

10ms

Overall (mm)

183(W)×
141(H) ×
3.5(D) mm

Active Area (mm)

162.00 × 121.50 mm

Refresh Rate

60Hz

Display Colors

16.7M

Panel Type

tft-lcd, lcm

Connector Type

RGB interface

Surface Treatment

Anti-Glare/Anti-Reflection/Anti-Fingerprints (custom optional)

Operating Temp

-20 ~
70 °C

Touchscreen Type

Capacitive Touch Panel (optional)

Storage Temp

−30°C to +80°C

Work Mode

Normally white, transmissive

Pixel Format

RGB vertical stripe

Input Voltage (V)

Weight (g)

600 g(Typ./Max.)

Operating Environment

Industrial indoor or controlled-light equipment after system qualification g(Typ./Max.)

Designed For

Industrial control panels, equipment HMI integration, self-service terminals, ATM systems, POS terminals, open-frame machines, home automation systems, medical devices, automotive applications, banking terminals, and embedded control systems.

8 Inch RGB Industrial HMI Touch Display Module for Control Panels

This 800 × 600 normally white transmissive display combines an RGB interface, anti-glare surface, and 380 cd/m² luminance, with the ordered touch stack defined for each project.

The RGB Industrial HMI Touch Display Module is an 8-inch landscape display platform for embedded control panels that need a 4:3 interface canvas and direct RGB video. The LCD uses a normally white transmissive a-Si TFT active matrix with 380 cd/m² luminance, an anti-glare surface, and a 12 o’clock viewing direction. The touch stack is configured per order, so its sensor technology, controller, interface, cover lens, and finished thickness must be confirmed before release.

An RGB interface label does not guarantee timing, voltage, pinout, or connector compatibility.

Touch data and LCD pixel data must be qualified as separate signal paths.

A 380 cd/m² panel does not establish direct-sun readability behind a finished front stack.

Key Specifications

ItemConfirmed value
Display size8.0 inches
Native resolution800 × 600 pixels
Active area162.00 × 121.50 mm
LCD outline183.00 × 141.00 × 3.50 mm
Display modeNormally white, transmissive
Technologya-Si TFT active matrix
Pixel arrangementRGB vertical stripe
Luminance380 cd/m²
Viewing direction12 o’clock
Surface treatmentAnti-glare
Display interfaceRGB
Controller referencesHX8262 + HX8696
BacklightWhite LED
Operating temperature−20°C to +70°C
Storage temperature−30°C to +80°C
Touch configurationProject-defined; exact technology and interface require confirmation

800 × 600 HMI Layout and Optical Fit

Native SVGA Content Planning

The 800 × 600 raster provides a 4:3 workspace for status pages, numeric controls, alarms, menus, and trend windows. Native rendering is preferred because uncontrolled scaling can soften small text or distort touch-target geometry. Confirm orientation, pixel-clock range, synchronization method, and the UI safe area before software layout is frozen.

380 cd/m² and Anti-Glare Treatment

The luminance rating is best positioned for indoor industrial equipment and controlled-light installations. Anti-glare treatment can soften sharp reflections from overhead lighting, but it is not an anti-reflective coating and does not prove outdoor readability. Cover glass, touch layers, air gaps, adhesives, and printed borders can reduce finished-stack contrast.

The 12 o’clock viewing direction should align with the normal operator position. Rotation without gray-scale testing may change the perceived image from above or below.

RGB Interface Integration for the RGB Industrial HMI Touch Display Module

Host Timing and Connector Qualification

Engineering review should confirm data width and color mapping, pixel clock, HSYNC, VSYNC, data-enable behavior, signal polarity, logic voltage, full pin assignment, FPC pitch, contact side, connector orientation, and cable length. The exact connector and pin count are not fixed in the confirmed product data, so they must come from the approved production drawing.

Panel logic and the white-LED backlight also require separate electrical definitions. Do not derive backlight voltage, current, driver topology, enable control, or dimming from the RGB label.

Controller-Document Boundary

HX8262 and HX8696 are the listed controller references. They help identify the display architecture but do not establish a compatible host initialization sequence, register package, power sequence, or interchangeable board design. Release software only against the approved module documentation and ordered revision.

Touch Configuration and Front-Stack Decisions

Define the Ordered Touch Path

The product family is positioned for touch-enabled industrial interfaces, while the exact implementation remains project-defined. Specify capacitive or resistive touch, touch-point count, controller, host interface, operating voltage, FPC position, cover-lens geometry, firmware requirements, and environmental targets.

The RGB display path and touch-control path must be reviewed independently. A host that drives the LCD does not automatically support the selected touch controller.

Bonding and Finished Mechanics

Air bonding may suit controlled indoor equipment where cost and serviceability are priorities. Optical bonding can be reviewed when lower internal reflection or a more integrated front stack is needed. The decision depends on the touch sensor, cover-glass thickness, bezel design, adhesive gap, repair strategy, and environment.

The 3.50 mm value is the LCD thickness, not the finished touch-module thickness. Use the approved touch drawing for the complete assembly envelope.

Mechanical and Environmental Integration

Active Area Versus Outline

The 162.00 × 121.50 mm active area defines the image region. The 183.00 × 141.00 × 3.50 mm outline defines the LCD envelope. Enclosure release also requires bezel opening, tolerances, connector clearance, FPC bend radius, component keep-outs, touch overhang, and cover-lens border.

Backlight and Temperature Review

The module uses a white-LED backlight, but electrical and lifetime grades are not fixed in the confirmed configuration. Select the driver only after voltage, current, string arrangement, dimming method, and thermal conditions are approved.

The LCD is specified for −20°C to +70°C operation and −30°C to +80°C storage. Finished-equipment testing should also consider humidity, condensation, thermal cycling, enclosure heat, and touch-controller limits.

Application Fit for Control Panels

The RGB Industrial HMI Touch Display Module fits equipment needing a compact 4:3 operator interface, including machine-control panels, appliance controls, building-automation stations, laboratory or test equipment, service terminals, and embedded information interfaces. Selection should follow the native UI, controlled-light luminance, viewing orientation, host capability, mechanical drawing, and ordered touch configuration.

This component is not a finished monitor. HDMI, DisplayPort, USB-C, LVDS, eDP, or MIPI hosts require a matched controller or converter that outputs the approved RGB timing. Sealing, impact resistance, regulatory compliance, and application safety remain finished-system responsibilities unless separately documented.

Customization and Project Qualification

Backlight and FPC customization are generally reviewed from 500 pieces, while touch customization is generally reviewed from 1,000 pieces. Sample and standard-module quantities are confirmed separately. Review may cover touch structure, cover lens, printed border, FPC direction, connector definition, luminance target, surface treatment, bonding, controller board, cables, enclosure fit, branding, and packaging.

Changes to the touch stack, cover lens, backlight, FPC, or bonding method can affect thickness, optics, power, tooling, lead time, and qualification scope.

Procurement Checklist

  • Confirm native 800 × 600 timing, orientation, and UI layout.
  • Confirm RGB data width, mapping, pixel clock, sync or DE mode, and polarity.
  • Obtain the complete connector/FPC pinout, pitch, contact side, and mating connector.
  • Define panel logic and backlight voltage, current, control, and driver scope.
  • Obtain HX8262 and HX8696 revision documentation.
  • Define touch technology, controller, interface, touch points, FPC, cover lens, and bonding.
  • Verify the 162.00 × 121.50 mm active area and 183.00 × 141.00 × 3.50 mm LCD outline.
  • Confirm the finished touch outline, thickness, bezel opening, and cable routing.
  • Validate 380 cd/m² behind the complete front stack in the target lighting.
  • State the environment, sample criteria, quantity, annual demand, and schedule.
Application Scenarios

FAQ

About 8 Inch RGB Industrial HMI Touch Display Module

What Must Be Checked Before Connecting an RGB Host?

Match the ordered data width, RGB mapping, pixel clock, synchronization or DE mode, polarity, logic voltage, and complete connector pinout. FPC pitch, contact side, mating connector, and cable orientation also matter. Backlight power is a separate design item.

Which Resolution Controls Controller and UI Selection?

Use 800 × 600 for this configuration. It matches the product title, model coding, and detailed module parameters, while a generic attribute field shows a conflicting 1280 × 800 value. Confirm the approved timing sheet and mechanical drawing before production release.

Is the Touch Controller Fixed?

No exact touch controller or interface is confirmed. The order must define touch technology, controller, host interface, touch points, FPC location, cover lens, bonding method, and finished thickness. RGB carries display pixels; touch coordinates use a separate control path.

Is 380 cd/m² Suitable Outdoors?

The rating is primarily suited to indoor or controlled-light equipment. It does not prove direct-sun readability after touch, cover glass, air gap, adhesive, or coating losses. High-ambient-light projects need a defined finished luminance target, reflection-control plan, enclosure, thermal design, and validation method.

Need a custom solution or samples?

Submit Requirements for Engineering Review For the RGB Industrial HMI Touch Display Module, submit the native timing, complete RGB and FPC definition, panel and backlight power, selected touch technology and controller, cover and bonding drawings, enclosure file, ambient-light target, operating environment, sample quantity, annual demand, and schedule. Engineering review covers timing and pin mapping, controller documentation, power and backlight design, touch integration, front-stack optics, mechanical fit, environmental boundaries, customization feasibility, and sample-validation criteria.
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.