75 Inch 5000 Nits UHD Outdoor LCD Panel for Window Signage

Product Gallery
Key Specs

Model P/N

HS750ENT-ND50

Size

75″

Resolution

3840×2160

Brightness

5000 (Typ.)(cd/m²)

Viewing Angle

89/89/89/89° (L/R/U/D, Min., CR≥10)

Connector Type

56-pin, eight-lane V-by-One

Operating Temp

-10 ~
60 °C

Overall(mm)

1689.6(W)×
967.9(H)×
46(D)
Upgrade Options (OEM/ODM)

huisoar

HS750ENT-ND50

General Features

Brand

huisoar

Panel Size (inch)

75"

Model P/N

HS750ENT-ND50

Resolution

3840×2160

Brightness (nits)

5000 cd/m² (Typ.)

Viewing Angle

89/89/89/89° (L/R/U/D, Min., CR≥10)

Contrast Ratio

1200:1 typical

Response Time

8 ms typical, G-to-G

Overall (mm)

1689.6(W)×
967.9(H) ×
46(D) mm

Active Area (mm)

1649.66(W) × 927.936(H) mm

Refresh Rate

60Hz

Bezel Opening

1651.6 × 930 mm

Display Colors

1.07B, 69% NTSC

Panel Type

tft-lcd, lcm

Connector Type

56-pin, eight-lane V-by-One

Surface Treatment

Matte, 3% haze, 2H hard coating

Operating Temp

-10 ~
60 °C

Touchscreen Type

Without

Storage Temp

-20 ~ 70°C

Work Mode

IPS, normally black, transmissive

Pixel Format

RGBW vertical stripe, 59 PPI

Input Voltage (V)

12.0 V typical

Control Type

Bare LCD panel requiring a matched V-by-One controller

Weight (g)

30500 g(Typ./Max.)

Operating Environment

High-ambient-light signage after optical, thermal and enclosure qualification g(Typ./Max.)

Motherboard Type

External controller with compatible eight-lane V-by-One output g(Typ./Max.)

Designed For

Digital signage displays, outdoor high-brightness displays, window-facing signage, retail and transportation hub displays, outdoor-facing digital signage, public information displays, and commercial information display systems.

75 Inch 5000 Nits UHD Outdoor LCD Panel for Window Signage

This 75-inch 4K RGBW IPS panel combines 5000 cd/m² luminance, a 56-pin V-by-One interface and a matte 2H surface for large window-facing display systems.

Product Summary

A 5000 Nits UHD Outdoor LCD Panel provides the optical and image-area foundation for large storefront, transport and public-information installations. The 75-inch panel uses a native 3840 × 2160 RGBW matrix with 59 PPI, a 1649.66 × 927.936 mm active area and wide-view IPS normally black operation.

The selected configuration is designed around 5000 cd/m² luminance. Its 1200:1 typical contrast ratio, 1.07B-color specification and 89°/89°/89°/89° viewing sequence support content seen from multiple approach positions. This is a bare LCD module, so the controller, backlight power, protective front, cabinet and environmental protection must be engineered into the finished display.

A native 3840 × 2160 panel is UHD/4K, not 8K.

Key Specifications

ParameterValue
Display size75 inches
Native resolution3840 × 2160 pixels, UHD
Pixel structureRGBW vertical stripe, 59 PPI
Active area1649.66 × 927.936 mm
Viewable area1651.6 × 930 mm
Panel modeIPS, normally black, transmissive
Selected luminance5000 cd/m²
Contrast ratio1200:1 typical
Viewing angles89°/89°/89°/89°, left/right/up/down
Surface treatmentMatte, 3% haze, 2H hard coating
Response time8 ms typical, G-to-G
Display colors1.07B colors, 69% NTSC
Standard refresh60 Hz
Signal interface56-pin V-by-One, eight lanes
Drive voltage12.0 V typical
BacklightWLED with LED driver
Listed backlight life50,000 hours
Panel weight27.6 kg typical / 30.5 kg maximum
Standard touchNo touch

These panel-level values define the starting point for controller, optical and cabinet qualification.

75-Inch 4K Content and Optical Planning

Prepare Native UHD Artwork

Content should be prepared for a 3840 × 2160 canvas. Advertising layouts, schedules, wayfinding and mixed text-plus-video screens should be tested at native resolution so fine text, line weights and image crops remain predictable across the 75-inch image area.

The RGBW vertical-stripe structure also requires sample review for small text and high-frequency graphics. An upstream player may decode an 8K file, but the final image still has to be scaled to the panel’s native 4K matrix.

Validate 5000 cd/m² Behind the Final Front

The 5000 cd/m² rating supports high-ambient-light design, but finished visibility depends on cover-glass transmission, reflections, air gaps, optical treatment, installation angle and solar load.

Test the production optical stack in the intended window-facing position. Night dimming and thermal control should be designed separately so the display does not remain at maximum luminance when the installation does not require it.

5000 Nits UHD Outdoor LCD Panel Integration

Qualify the 56-Pin V-by-One Link

A 56-pin connector and eight-lane V-by-One designation do not establish controller compatibility by themselves. Approval must cover the complete pin assignment, lane mapping, data rate, timing, connector orientation, cable design, color format and required control signals.

The host should output native 3840 × 2160 timing at the approved standard refresh mode. Cable routing and grounding must be tested in the final cabinet, particularly when the controller and panel are separated by a long internal cable path.

Separate Panel Power from Finished-System Power

The 12.0 V reference applies to the panel rail, not to the complete signage system. The WLED backlight and driver require confirmed voltage, current, enable and dimming data, while the media player, thermal system and optional sensors add separate electrical loads.

Obtain the approved electrical specification before selecting the power supply or harness. The final design should include suitable protection, connector current capacity and controlled startup behavior.

Motion, Viewing and Backlight Interpretation

Treat 60 Hz as the Standard Panel Mode

The standard panel refresh is 60 Hz. Descriptions of 120 Hz or 240 Hz operation are associated with MEMC or panel-plus-backlight processing modes and should not be rewritten as proof of native 120 Hz or 240 Hz operation.

Confirm the processing board and backlight-control architecture before promising higher-rate motion performance. Native 60 Hz operation remains appropriate for most advertising, route information and public-messaging content.

Use Wide Viewing Without Overstating Visibility

The IPS normally black structure and confirmed 89° viewing sequence help maintain image consistency across broad approach positions. This benefits storefronts, station concourses and public-information sites where viewers do not remain directly in front of the screen.

Wide panel viewing does not eliminate front-surface reflections. The finished cover, bonding method and installation lighting still require validation.

Mechanical and Thermal Integration

The active and viewable areas support front-window planning, but they do not replace a complete outline and mounting drawing. Use the approved mechanical document to determine outer dimensions, support points, rear clearance, connector access and allowable loading.

The 27.6 kg typical panel weight and 30.5 kg maximum value require a structural frame designed for transport, installation and long-term vertical loading. The cabinet should prevent panel twist and provide service access for the controller, cable and backlight system.

Thermal design must be qualified at the selected luminance and installation orientation. The approved operating and storage limits should be fixed in the purchase specification before environmental release.

Application Fit and Selection Boundaries

This 5000 Nits UHD Outdoor LCD Panel is suitable for window-facing retail signage, transport information boards, public-information displays, premium advertising structures and other high-ambient-light systems requiring a 75-inch 4K image area.

It is not a finished waterproof monitor. Outdoor deployment requires a qualified enclosure, front protection, sealing, thermal path, mounting structure and electrical system. The standard panel is non-touch; interactive use requires a separately engineered touch overlay, controller and front-stack drawing.

Configuration and Customization

Project review can cover brightness confirmation, V-by-One cable and controller matching, cover glass, anti-reflective treatment, optical bonding, touch integration, backlight control, cabinet structure, thermal management, mounting and branding.

Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability and the requested specification. Sample and standard-panel quantities are confirmed separately.

Procurement Checklist

Confirm before sample or production approval:

  • Approved 5000 cd/m² production configuration
  • Native 3840 × 2160 timing and standard refresh mode
  • RGBW content and scaling validation
  • Complete eight-lane V-by-One definition
  • 56-pin assignment and connector orientation
  • 12.0 V panel rail and current requirement
  • WLED voltage, current, enable and dimming data
  • Active-area and viewable-area alignment
  • Complete outline and support drawing
  • 27.6 kg typical / 30.5 kg maximum load
  • Cover-glass transmission and reflection target
  • Optical bonding or air-gap design
  • Cabinet cooling and solar-load assumptions
  • Approved operating and storage limits
  • Standard non-touch or custom touch requirement
  • Sample criteria, quantity and annual demand
Application Scenarios

FAQ

About 75 Inch 5000 Nits UHD Outdoor LCD Panel

Does the 8K wording mean this panel has 7680 × 4320 resolution?

No. The native matrix is 3840 × 2160, so the panel is UHD/4K. Prepare controller timing, media output and artwork for 4K operation. An upstream player may decode an 8K file, but the image must be scaled before display. Customer-facing specifications should therefore describe the panel as 4K or UHD rather than native 8K.

What must be checked before connecting a 56-pin V-by-One controller?

Confirm the complete eight-lane mapping, data rate, native timing, color format, 56-pin assignment, connector orientation and 12.0 V panel requirements. A matching connector does not prove electrical or timing compatibility. Submit the controller model, cable drawing and pin table for review, then validate a production-intent cable and panel sample before releasing the controller PCB or cabinet harness.

Is 5000 cd/m² sufficient for direct-sun window signage?

The value provides a strong luminance basis, but approval depends on the final optical stack and site conditions. Test the panel behind the planned cover glass with the actual air gap or bonding method, installation angle and daylight exposure. Record apparent contrast, thermal behavior and nighttime dimming requirements before releasing the final brightness strategy.

Do the 120 Hz and 240 Hz statements establish native panel refresh?

No. The standard mode is 60 Hz, while the higher-rate statements are connected to MEMC or panel-plus-backlight processing descriptions. Confirm which processing board and backlight-control method belong to the ordered system. Do not advertise native 120 Hz or 240 Hz unless the approved configuration documentation explicitly establishes it.

What mechanical information is required before cabinet release?

Obtain the complete outline, support-point and connector-location drawing in addition to the 1649.66 × 927.936 mm active area. The structure must support 27.6 kg typical and up to 30.5 kg while preventing frame twist and allowing cable access. Review transport loading, mounting orientation, thermal clearance and front-window alignment with a physical sample.

Need a custom solution or samples?

Request a Sample and Technical Review For a 5000 Nits UHD Outdoor LCD Panel project, submit the controller model, native UHD timing, complete V-by-One definition, panel and backlight power data, cabinet drawing, cover-glass stack, installation lighting, touch requirement, sample quantity and annual demand. Engineering review covers V-by-One compatibility, content scaling, electrical architecture, backlight control, optical performance, structural support, thermal design, touch configuration and available customization.
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.