Freya Yang
+86 18318948097
+852 62667476
75 Inch 5000 Nits UHD Outdoor LCD Panel for Window Signage
Model P/N
Size
Resolution
Brightness
Viewing Angle
Connector Type
Operating Temp
Overall(mm)
huisoar
HS750ENT-ND50
Brand
Panel Size (inch)
Model P/N
Resolution
Brightness (nits)
Viewing Angle
Contrast Ratio
Response Time
Overall (mm)
Active Area (mm)
Refresh Rate
Bezel Opening
Display Colors
Panel Type
Connector Type
Surface Treatment
Operating Temp
Touchscreen Type
Storage Temp
Work Mode
Pixel Format
Input Voltage (V)
Control Type
Weight (g)
Operating Environment
Motherboard Type
Designed For
75 Inch 5000 Nits UHD Outdoor LCD Panel for Window Signage
This 75-inch 4K RGBW IPS panel combines 5000 cd/m² luminance, a 56-pin V-by-One interface and a matte 2H surface for large window-facing display systems.
Product Summary
A 5000 Nits UHD Outdoor LCD Panel provides the optical and image-area foundation for large storefront, transport and public-information installations. The 75-inch panel uses a native 3840 × 2160 RGBW matrix with 59 PPI, a 1649.66 × 927.936 mm active area and wide-view IPS normally black operation.
The selected configuration is designed around 5000 cd/m² luminance. Its 1200:1 typical contrast ratio, 1.07B-color specification and 89°/89°/89°/89° viewing sequence support content seen from multiple approach positions. This is a bare LCD module, so the controller, backlight power, protective front, cabinet and environmental protection must be engineered into the finished display.
A native 3840 × 2160 panel is UHD/4K, not 8K.
Key Specifications
| Parameter | Value |
|---|---|
| Display size | 75 inches |
| Native resolution | 3840 × 2160 pixels, UHD |
| Pixel structure | RGBW vertical stripe, 59 PPI |
| Active area | 1649.66 × 927.936 mm |
| Viewable area | 1651.6 × 930 mm |
| Panel mode | IPS, normally black, transmissive |
| Selected luminance | 5000 cd/m² |
| Contrast ratio | 1200:1 typical |
| Viewing angles | 89°/89°/89°/89°, left/right/up/down |
| Surface treatment | Matte, 3% haze, 2H hard coating |
| Response time | 8 ms typical, G-to-G |
| Display colors | 1.07B colors, 69% NTSC |
| Standard refresh | 60 Hz |
| Signal interface | 56-pin V-by-One, eight lanes |
| Drive voltage | 12.0 V typical |
| Backlight | WLED with LED driver |
| Listed backlight life | 50,000 hours |
| Panel weight | 27.6 kg typical / 30.5 kg maximum |
| Standard touch | No touch |
These panel-level values define the starting point for controller, optical and cabinet qualification.
75-Inch 4K Content and Optical Planning
Prepare Native UHD Artwork
Content should be prepared for a 3840 × 2160 canvas. Advertising layouts, schedules, wayfinding and mixed text-plus-video screens should be tested at native resolution so fine text, line weights and image crops remain predictable across the 75-inch image area.
The RGBW vertical-stripe structure also requires sample review for small text and high-frequency graphics. An upstream player may decode an 8K file, but the final image still has to be scaled to the panel’s native 4K matrix.
Validate 5000 cd/m² Behind the Final Front
The 5000 cd/m² rating supports high-ambient-light design, but finished visibility depends on cover-glass transmission, reflections, air gaps, optical treatment, installation angle and solar load.
Test the production optical stack in the intended window-facing position. Night dimming and thermal control should be designed separately so the display does not remain at maximum luminance when the installation does not require it.
5000 Nits UHD Outdoor LCD Panel Integration
Qualify the 56-Pin V-by-One Link
A 56-pin connector and eight-lane V-by-One designation do not establish controller compatibility by themselves. Approval must cover the complete pin assignment, lane mapping, data rate, timing, connector orientation, cable design, color format and required control signals.
The host should output native 3840 × 2160 timing at the approved standard refresh mode. Cable routing and grounding must be tested in the final cabinet, particularly when the controller and panel are separated by a long internal cable path.
Separate Panel Power from Finished-System Power
The 12.0 V reference applies to the panel rail, not to the complete signage system. The WLED backlight and driver require confirmed voltage, current, enable and dimming data, while the media player, thermal system and optional sensors add separate electrical loads.
Obtain the approved electrical specification before selecting the power supply or harness. The final design should include suitable protection, connector current capacity and controlled startup behavior.
Motion, Viewing and Backlight Interpretation
Treat 60 Hz as the Standard Panel Mode
The standard panel refresh is 60 Hz. Descriptions of 120 Hz or 240 Hz operation are associated with MEMC or panel-plus-backlight processing modes and should not be rewritten as proof of native 120 Hz or 240 Hz operation.
Confirm the processing board and backlight-control architecture before promising higher-rate motion performance. Native 60 Hz operation remains appropriate for most advertising, route information and public-messaging content.
Use Wide Viewing Without Overstating Visibility
The IPS normally black structure and confirmed 89° viewing sequence help maintain image consistency across broad approach positions. This benefits storefronts, station concourses and public-information sites where viewers do not remain directly in front of the screen.
Wide panel viewing does not eliminate front-surface reflections. The finished cover, bonding method and installation lighting still require validation.
Mechanical and Thermal Integration
The active and viewable areas support front-window planning, but they do not replace a complete outline and mounting drawing. Use the approved mechanical document to determine outer dimensions, support points, rear clearance, connector access and allowable loading.
The 27.6 kg typical panel weight and 30.5 kg maximum value require a structural frame designed for transport, installation and long-term vertical loading. The cabinet should prevent panel twist and provide service access for the controller, cable and backlight system.
Thermal design must be qualified at the selected luminance and installation orientation. The approved operating and storage limits should be fixed in the purchase specification before environmental release.
Application Fit and Selection Boundaries
This 5000 Nits UHD Outdoor LCD Panel is suitable for window-facing retail signage, transport information boards, public-information displays, premium advertising structures and other high-ambient-light systems requiring a 75-inch 4K image area.
It is not a finished waterproof monitor. Outdoor deployment requires a qualified enclosure, front protection, sealing, thermal path, mounting structure and electrical system. The standard panel is non-touch; interactive use requires a separately engineered touch overlay, controller and front-stack drawing.
Configuration and Customization
Project review can cover brightness confirmation, V-by-One cable and controller matching, cover glass, anti-reflective treatment, optical bonding, touch integration, backlight control, cabinet structure, thermal management, mounting and branding.
Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability and the requested specification. Sample and standard-panel quantities are confirmed separately.
Procurement Checklist
Confirm before sample or production approval:
- Approved 5000 cd/m² production configuration
- Native 3840 × 2160 timing and standard refresh mode
- RGBW content and scaling validation
- Complete eight-lane V-by-One definition
- 56-pin assignment and connector orientation
- 12.0 V panel rail and current requirement
- WLED voltage, current, enable and dimming data
- Active-area and viewable-area alignment
- Complete outline and support drawing
- 27.6 kg typical / 30.5 kg maximum load
- Cover-glass transmission and reflection target
- Optical bonding or air-gap design
- Cabinet cooling and solar-load assumptions
- Approved operating and storage limits
- Standard non-touch or custom touch requirement
- Sample criteria, quantity and annual demand


FAQ
About 75 Inch 5000 Nits UHD Outdoor LCD Panel
Does the 8K wording mean this panel has 7680 × 4320 resolution?
What must be checked before connecting a 56-pin V-by-One controller?
Is 5000 cd/m² sufficient for direct-sun window signage?
Do the 120 Hz and 240 Hz statements establish native panel refresh?
What mechanical information is required before cabinet release?
Freya Yang
+86 18318948097





