10.1 Inch Medical Equipment Industrial HMI Display Screen

Product Gallery
Key Specs

Model P/N

HS101090S0

Size

10.1″

Resolution

1280×800

Brightness

900 (Typ.)(cd/m²)

Viewing Angle

85°/85°/85°/85° typical, L/R/U/D, CR ≥ 10

Connector Type

40-pin 8-bit LVDS

Operating Temp

-30 ~
80 °C

Overall(mm)

229.1(W)×
148.9(H)×
4.3(D)
Upgrade Options (OEM/ODM)

huisoar

HS101090S0

General Features

Brand

huisoar

Panel Size (inch)

10.1"

Model P/N

HS101090S0

Resolution

1280×800

Brightness (nits)

900 cd/m² (Typ.)

Viewing Angle

85°/85°/85°/85° typical, L/R/U/D, CR ≥ 10

Contrast Ratio

900:1 (Typ.)

Response Time

6ms

Overall (mm)

229.1(W)×
148.9(H) ×
4.3(D) mm

Active Area (mm)

216.96 (W) × 135.6 (H) mm

Refresh Rate

75Hz

Display Colors

16.7M colors

Panel Type

tft-lcd, lcm

Connector Type

40-pin 8-bit LVDS

Operating Temp

-30 ~
80 °C

Touchscreen Type

Without Touch

Storage Temp

−30°C to +80°C

Work Mode

Normally black, transmissive

Operating Environment

Professional equipment / industrial HMI after system qualification g(Typ./Max.)

Designed For

Medical-equipment and industrial-HMI component integration, outdoor high-brightness equipment, vehicle displays, instrument panels, medical equipment

10.1 Inch Medical Equipment Industrial HMI Display Screen

A Medical Equipment Industrial HMI Display Screen in a 10.1-inch format gives engineering teams a 1280 × 800 landscape workspace, 900 cd/m² typical luminance, full-view IPS performance and a 40-pin 8-bit LVDS interface. The module has a 216.96 × 135.6 mm active area and a compact 229.1 × 148.9 × 4.3 mm outline, while its −30°C to +80°C operating range supports equipment that must function across broader environmental conditions. The standard configuration is non-touch.

Product Summary

This 10.1-inch TFT-LCD is intended for professional equipment where mechanical fit, signal definition, viewing consistency and environmental range are important parts of the design-in process. The 1280 × 800 raster provides a 16:10 landscape workspace that can accommodate operating menus, numerical data, status regions, alarms and graphical controls.

1280 × 800 Workspace for Equipment Interfaces

The native WXGA layout gives interface designers enough room to separate primary information from secondary controls without moving to a substantially larger display. Driving the panel at its native 1280 × 800 timing also avoids unnecessary image scaling during controller integration.

Full-View IPS Performance

IPS full-view construction and 85°/85°/85°/85° typical viewing angles help maintain usable visibility when an operator views the display from different positions. This can be useful in control panels, instrumentation and professional equipment where the screen is not always viewed directly from the center.

Key Specifications

ParameterSpecification
Size10.1 inches
Resolution1280 × 800 pixels
Active Area216.96 × 135.6 mm
Module Outline229.1 × 148.9 × 4.3 mm
Brightness900 cd/m² typical
Contrast Ratio900:1 typical
Viewing Angle85°/85°/85°/85° typical, L/R/U/D
Display Colors16.7M colors
Interface40-pin 8-bit LVDS
Panel Typea-Si TFT-LCD, IPS full-view
BacklightWLED
TouchNo touch
Operating Temperature−30°C to +80°C
Storage Temperature−30°C to +80°C

900 cd/m² Optical Performance

The fixed 900 cd/m² typical luminance gives the panel useful optical headroom for bright indoor equipment, machinery cabins and protected high-ambient-light installations. It should not be converted into a blanket claim that every finished system will remain readable under every outdoor lighting condition.

Bright-Ambient Readability

Final visibility depends on more than panel luminance. Front-window transmission, reflections, screen angle, enclosure geometry and ambient lighting all affect the contrast seen by the operator.

A 900 cd/m² panel should be evaluated behind the final cover stack under the target lighting.

Front Cover and Optical Qualification

Where a project adds cover glass or another protective front layer, engineers should confirm the resulting optical loss and reflection behavior. AG, AR or bonding requirements should be treated as separate project specifications rather than assumed standard module features.

Integrating the Medical Equipment Industrial HMI Display Screen

The 40-pin 8-bit LVDS interface is a central qualification point for controller-board and cable selection. A connector with the same number of pins is not enough to establish electrical compatibility.

40-Pin 8-Bit LVDS Qualification

Before sample power-up or cable release, confirm native 1280 × 800 timing, LVDS channel and bit mapping, complete pin assignment, connector pitch, contact orientation, panel power and backlight-driver requirements.

A matching 40-pin LVDS connector does not guarantee timing, voltage, mapping, pin assignment or controller compatibility.

Current industrial-display engineering guidance likewise treats the complete pinout, mapping, voltage and timing definition as necessary before replacing or matching another LVDS panel.

EK79202 Documentation Boundary

EK79202 is identified as the display chip for this configuration. The component identifier can help engineering teams locate the correct product documentation, but it should not be used to infer initialization sequences, register programming or power sequencing.

EK79202 does not by itself establish host-side programming requirements.

Mechanical Integration

The module provides a 216.96 × 135.6 mm active image area inside a 229.1 × 148.9 × 4.3 mm envelope. Those values serve different design purposes and should not be interchanged when defining an enclosure.

Active Area and Module Outline

The active area controls the visible image region. The larger module outline controls enclosure clearance, support and front-panel planning. Final tooling should also account for the connector position, cable bend, frame overlap and manufacturing tolerance.

Non-Touch System Architecture

The standard configuration is supplied without touch.

The standard configuration is non-touch.

Projects requiring user interaction can use external keys, buttons, encoders or another control method. If a separate touchscreen is later considered, the combined mechanical stack, touch controller, interface, cover design and optical impact require independent engineering qualification.

Wide-Temperature Operation

The Medical Equipment Industrial HMI Display Screen is specified for operation from −30°C to +80°C and storage from −30°C to +80°C. This gives equipment designers a broad component temperature window for machinery, industrial electronics and other installations exposed to significant environmental variation.

The component temperature range does not establish an IP rating, condensation resistance, UV resistance, vibration grade or the environmental rating of the finished equipment. Those requirements belong to system qualification.

Medical Equipment and Industrial Application Fit

Medical-Instrument Integration Boundary

The module can be evaluated for medical-instrument interfaces where a 10.1-inch landscape display, IPS viewing, LVDS input and non-touch architecture fit the device design.

Medical-equipment application wording does not establish finished-device medical certification.

Finished equipment must be qualified against the electrical, EMC, cleaning, safety and regulatory requirements that apply to the actual device and market.

Industrial and Machinery Interfaces

The combination of 1280 × 800 resolution, 900 cd/m² luminance, 40-pin LVDS and wide-temperature operation can also support industrial HMI panels, agricultural-machinery controls, instrumentation, equipment status interfaces and qualified vehicle-adjacent display subassemblies. Installation-specific mechanical, electrical and environmental requirements still need to be locked before production.

Procurement Checklist

Before sample approval, confirm the production revision, native 1280 × 800 timing, complete 40-pin 8-bit LVDS pinout and mapping, connector orientation, panel power, WLED electrical requirements, EK79202 documentation where needed, 216.96 × 135.6 mm active area, 229.1 × 148.9 × 4.3 mm module fit, 900 cd/m² luminance tolerance, 900:1 contrast, viewing-angle requirement, non-touch architecture, −30°C to +80°C environmental requirement, front-window conditions, sample quantity and annual demand.

Application Scenarios

FAQ

About 10.1 Inch Medical Equipment Industrial HMI Display Screen

What must be checked before replacing another 40-pin LVDS panel?

The full electrical and mechanical definition must match. For this 1280 × 800 module, confirm the LVDS timing, channel/bit mapping, complete 40-pin pinout, connector orientation, panel supply and WLED requirements. A shared pin count alone does not establish compatibility. Replacement-panel FAQ and engineering guidance commonly highlight this exact risk.

Is 900 cd/m² enough behind a protective front window?

It provides a strong high-ambient-light starting point, but the finished result depends on the optical stack. Cover transmission, reflected ambient light, surface treatment and screen position affect viewed contrast. The engineering action is to test the assembled unit under the intended lighting rather than approve visibility from the panel luminance alone. Current industrial-display guidance similarly treats luminance and reflection control together.

What does the medical-equipment application claim establish?

It establishes an application direction for component selection, not medical-device certification. This panel provides the display characteristics needed for equipment integration, but the final medical device still needs its own applicable safety, EMC, cleaning and regulatory qualification.

What should be reviewed if the project later requires touch?

Touch is not part of the standard configuration. A separate touch solution requires a combined drawing, cover dimensions, controller/interface selection, FPC routing, optical-stack evaluation and confirmation that the additional thickness still fits the enclosure.

How should the −30°C to +80°C range be used during qualification?

Both operating and storage limits are stated as −30°C to +80°C for this configuration. System qualification must still consider the actual enclosure temperature, backlight heat, condensation, cable materials and other components whose temperature limits may differ.

Need a custom solution or samples?

Request a Sample and Engineering Review For a Medical Equipment Industrial HMI Display Screen sample review, submit your controller or host platform, native 1280 × 800 requirements, full LVDS pinout or existing panel reference, enclosure drawing, front-window structure, environmental range, medical-equipment qualification requirements where applicable, sample quantity and forecast demand. Engineering review covers LVDS compatibility, panel and backlight electrical requirements, mechanical fit, optical performance, wide-temperature conditions, non-touch or separately engineered touch architecture and project-specific adaptation.
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.