10.1 Inch Medical Portrait MIPI IPS LCD Display for Control Panels

Product Gallery
Key Specs

Model P/N

HS100035B2

Size

10.1″

Resolution

800×1280

Brightness

550 (Typ.)(cd/m²)

Viewing Angle

80°/80°/80°/80° L/R/U/D

Connector Type

40-pin MIPI

Operating Temp

-10 ~
60 °C

Overall(mm)

143(W)×
228.6(H)×
2.8(D)
Upgrade Options (OEM/ODM)

huisoar

HS100035B2

General Features

Brand

huisoar

Panel Size (inch)

10.1"

Model P/N

HS100035B2

Resolution

800×1280

Brightness (nits)

550 cd/m² (Typ.)

Viewing Angle

80°/80°/80°/80° L/R/U/D

Contrast Ratio

1000:1 typical

Response Time

12ms

Overall (mm)

143(W)×
228.6(H) ×
2.8(D) mm

Active Area (mm)

135.36 (W) × 216.576 (H) mm

Refresh Rate

60Hz

Display Colors

16.7M colors

Panel Type

tft-lcd, lcm

Connector Type

40-pin MIPI

Surface Treatment

N/A

Operating Temp

-10 ~
60 °C

Touchscreen Type

Optional Custom Touch Screen

Storage Temp

−20°C to +70°C

Work Mode

IPS full-view family, transmissive

Pixel Format

RGB stripe

Operating Environment

Requires project-level environmental qualification; no IP/humidity rating confirmed g(Typ./Max.)

Designed For

Tablet systems, industrial equipment displays, vehicle displays, smart home control panels, medical display panels, security and access-control interfaces, embedded industrial systems, and qualified medical and automotive display-integration projects.

10.1 Inch Medical Portrait MIPI IPS LCD Display for Control Panels

A 10.1-inch 800 × 1280 non-touch module combines 550 cd/m² IPS viewing with a 40-pin MIPI connection for portrait embedded interfaces.

The Medical Portrait MIPI IPS LCD Display is a 10.1-inch portrait TFT-LCD module for equipment that benefits from a vertically organized user interface. Its 800 × 1280 resolution, IPS viewing characteristics, 550 cd/m² typical luminance and 40-pin MIPI connection create a practical platform for control panels, access-control terminals, smart-home interfaces and medical-equipment projects that require a compact portrait screen.

Product Summary

800 × 1280 portrait geometry

The 10:16 screen format provides more vertical workspace than a conventional landscape panel. Interface designers can use the native canvas for menu lists, status fields, parameter pages, prompts and other information that naturally flows from top to bottom.

The native 800 × 1280 raster should be driven directly for portrait interface design rather than treated as a rotated widescreen canvas.

IPS viewing with a defined luminance target

IPS panel technology is paired with 80°/80°/80°/80° viewing performance in the stated left/right/up/down order. A 1000:1 typical contrast ratio and 16.7M-color capability support text, graphics, icons and embedded interface content.

The 550 cd/m² typical rating provides a defined optical target for system validation, but the finished result still depends on the front cover, reflection and installation lighting.

Key Specifications

ParameterSpecification
Display size10.1 inches
Resolution800 × 1280 pixels
Aspect ratio10:16 portrait
Panel familya-Si TFT-LCD, IPS
Optical typeTransmissive
Active area135.36 × 216.576 mm
Structure reference143 × 228.6 × 2.8 mm
Luminance550 cd/m² typical
Contrast ratio1000:1 typical
Viewing angle80°/80°/80°/80° L/R/U/D
Colors16.7M
Pixel arrangementRGB stripe
InterfaceMIPI
Connector count40 pins
BacklightWLED
TouchNo touch
Operating temperature−10°C to +60°C
Storage temperature−20°C to +70°C

Portrait UI and Mechanical Planning

Prepare the interface for the native canvas

An 800 × 1280 portrait layout works well when information is organized into vertical navigation, stacked parameter blocks, patient or equipment status areas, access-control steps, home-control menus or similar interface patterns.

Designing directly around the native raster reduces unnecessary scaling and gives UI teams predictable control over text size, icons and status regions.

Separate active area from total module structure

The visible active area measures 135.36 × 216.576 mm. The more detailed structure reference is 143 × 228.6 × 2.8 mm, so the enclosure needs to account for both the image window and the surrounding module structure.

Mechanical records also contain a separate 2 mm maximum-thickness entry. The approved production drawing should resolve that difference before enclosure tooling is released.

Integrating the Medical Portrait MIPI IPS LCD Display

Qualify the 40-pin MIPI host completely

The standard module uses a 40-pin MIPI interface. Connector count alone is not sufficient for electrical approval.

A 40-pin MIPI connector does not guarantee lane count, operating mode, timing, voltage, pin mapping or host compatibility.

Engineering teams should therefore lock the complete pin assignment, connector orientation, host timing requirements, voltage domains and any required panel initialization documentation before the controller design enters production.

Keep the non-touch baseline explicit

The standard configuration is non-touch. This can be useful for equipment controlled through buttons, keys, rotary controls or another independent input device, and it also provides a clean display foundation when a project-specific front structure is required.

If touch is needed, the touch technology, controller, interface, cover structure and final mechanical stack should be specified as a separate project configuration rather than assumed from the MIPI display connector.

Optical and Environmental Qualification

Validate 550 cd/m² behind the final front cover

The panel is rated at 550 cd/m² typical luminance. Protective glass, bonding materials, air gaps, coatings and reflections can change the effective brightness seen by the operator.

The 550 cd/m² panel rating does not by itself establish diagnostic-display or direct-sun performance behind the finished front stack.

Projects should evaluate the complete optical assembly under representative lighting before approving the final display configuration.

Keep operating and storage limits separate

The operating range is −10°C to +60°C, while storage is specified from −20°C to +70°C. These limits describe the component configuration and should not be expanded into a wider finished-equipment environmental rating.

Enclosure temperature, humidity, sealing, shock, vibration and regulatory requirements still need to be established at system level.

Application Fit for Medical and Control Equipment

Medical-equipment integration requires system qualification

The Medical Portrait MIPI IPS LCD Display can be evaluated for medical-equipment interface projects where a portrait screen, wide viewing and a non-touch architecture fit the device design.

Medical-equipment use is an integration direction and still requires finished-device regulatory and performance qualification.

The display specification alone does not establish diagnostic-image performance, medical certification, electromagnetic compliance or any other finished-device approval.

Security, smart-home and industrial control panels

The portrait format also fits access-control terminals, security interfaces, smart-home control panels, tablet-style embedded systems and industrial control equipment. These applications can benefit from vertically organized workflows and the relatively slim module structure.

Vehicle-display concepts may also be evaluated when the complete product is separately qualified for its electrical, environmental, vibration and regulatory requirements.

Customization and Project Qualification

Project review can cover MIPI pin definition, FPC geometry, interface adaptation, cover glass, anti-glare or anti-reflective treatment, optical bonding, separate touch development, brightness/backlight requirements, enclosure adaptation, cable routing, branding and packaging.

Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability and the requested specification. Sample and standard-module quantities are confirmed separately.

Procurement Checklist

Before sampling, confirm the native 800 × 1280 timing and orientation, MIPI lane count and operating mode, complete 40-pin assignment, connector pitch and orientation, interface voltage requirements, and any required initialization package.

Also lock the 135.36 × 216.576 mm active area, resolve the 143 × 228.6 × 2.8 mm structure reference against the separate 2 mm thickness entry, define the 550 cd/m² acceptance method, and confirm the non-touch baseline or any separate touch requirement.

For medical or other regulated equipment, provide the project-specific compliance, optical, environmental and documentation requirements instead of inferring them from the LCD component specification.

Application Scenarios

FAQ

About 10.1 Inch Medical Portrait MIPI IPS LCD Display

What must be checked before connecting a 40-pin MIPI host?

The complete interface definition must be checked, not just the 40-pin connector count. Confirm native 800 × 1280 timing, lane count, operating mode, data rate, pin assignment, voltage domains, connector orientation and any required initialization information. A mechanically matching connector can still represent a different electrical or protocol configuration, so host approval should use the exact production documentation.

How should the 800 × 1280 interface be prepared for portrait use?

Build the UI around the native 800 × 1280 canvas whenever possible. The active area is 135.36 × 216.576 mm, so text, navigation and status blocks can be designed around the actual portrait geometry instead of scaling a landscape interface. Validate typography and critical status information at the real viewing distance before freezing the GUI.

Is 550 cd/m² sufficient behind a front cover?

It depends on the complete optical stack and installation lighting. The panel value is 550 cd/m² typical, but cover-glass transmission, reflection, bonding layers and ambient illumination can change apparent visibility. Submit the intended front-window structure and lighting environment so the finished optical requirement can be evaluated rather than approving the design from panel luminance alone.

What must be confirmed before using the module in medical equipment?

Treat medical use as an equipment-integration project rather than a certification claim. The module provides 800 × 1280 portrait imaging, IPS viewing, 550 cd/m² typical luminance and a non-touch baseline, but the finished device still needs its own performance, regulatory, EMC, environmental and usability qualification. Provide those project requirements during engineering review.

Which thickness value should control enclosure release?

Use the approved production drawing before tooling. The detailed structure reference gives 143 × 228.6 × 2.8 mm, while another technical field lists 2 mm as maximum thickness. Because these values are not identical, enclosure clearance and mounting features should not be finalized until the ordered production revision resolves the mechanical stack.

Need a custom solution or samples?

Request Engineering Review For a Medical Portrait MIPI IPS LCD Display project, submit the host processor or controller, native 800 × 1280 timing, MIPI requirements, complete pin definition, enclosure drawing, front-window or touch plan, lighting conditions, environmental requirements, sample quantity and annual demand. Engineering review covers MIPI compatibility, optical fit, mechanical clearance, non-touch or separate-touch architecture, temperature boundaries and feasible customization.
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.