7.84 Inch Narrow Equipment Display Module for Control Panels
Model P/N
Size
Resolution
Brightness
Viewing Angle
Connector Type
Operating Temp
Overall(mm)
huisoar
HS078C8813M
Brand
Panel Size (inch)
Model P/N
Resolution
Brightness (nits)
Viewing Angle
Contrast Ratio
Response Time
Overall (mm)
Active Area (mm)
Refresh Rate
Bezel Opening
Display Colors
Panel Type
Connector Type
Operating Temp
Touchscreen Type
Storage Temp
Work Mode
Control Type
Operating Environment
Designed For
7.84 Inch Narrow Equipment Display Module for Control Panels
Its 400 × 1280 portrait canvas, 450 cd/m² IPS optics and 40-pin MIPI connection support narrow industrial control and status interfaces.
Product Summary
The Narrow Equipment Display Module is a 7.84-inch a-Si TFT-LCD component for equipment that needs a tall visual area rather than a conventional widescreen panel. Its 59.4 × 190.08 mm active area can present alarms, operating states, menu lists, process values and segmented graphics within a slim opening.
The confirmed configuration combines 400 × 1280 pixels, 450 cd/m² typical luminance, IPS full viewing, a 900:1 typical contrast ratio and 16.7M colors. The native display connection is MIPI with 40 pins, while the standard module is non-touch.
A 40-pin MIPI connector does not establish lane, timing, voltage or pin compatibility. Native 400 × 1280 content avoids unnecessary scaling. The 450 cd/m² panel rating must be evaluated behind the final front lens under the intended lighting.
Key Specifications at a Glance
| Item | Confirmed value |
|---|---|
| Screen size | 7.84 inches |
| Resolution | 400 × 1280 pixels |
| Panel construction | a-Si TFT-LCD, IPS family |
| Active area | 59.4 × 190.08 mm |
| Module dimensions | 68.7 × 213.48 × 6.28 mm |
| Luminance | 450 cd/m² typical |
| Contrast ratio | 900:1 typical |
| Viewing angle | 80°/80°/80°/80° left/right/up/down |
| Display colors | 16.7M colors |
| Display interface | MIPI, 40 pins |
| Backlight | WLED, 24 white LEDs |
| Touch status | Non-touch |
| Operating temperature | −20°C to +70°C |
| Storage temperature | −30°C to +80°C |
Tall 400 × 1280 Layout for Narrow Control Panels
Native Portrait UI Planning
Design the interface specifically for 400 × 1280 pixels. Suitable layouts include vertically stacked status blocks, machine-state lists, guided operating steps and narrow information bands. Establish text size, line spacing, icon dimensions and safe margins at the actual viewing distance rather than rotating or cropping a standard landscape interface.
IPS Viewing for Side-Angle Readability
The 80°/80°/80°/80° viewing angles support equipment doors, upright consoles and shared status panels that may be viewed off center. Final performance also depends on the front lens, air gap, tint, surface reflection and mounting angle, so these factors should be assessed with an assembled sample.
450 cd/m² Controlled-Light Visibility
The fixed luminance statement is 450 cd/m² typical. It is suitable for evaluation in indoor industrial spaces and controlled-light equipment, but it should not be converted into a sunlight-readable claim. Optical review should use the intended lens material, printing, coating or bonding stack and the real ambient-light target.
Narrow Equipment Display Module Integration
40-Pin MIPI Host Qualification
Confirm the MIPI lane configuration, operating mode, pixel format, video timing, clock requirements, voltage rails, complete 40-pin assignment, reset and control signals, and FPC contact orientation. Pin count alone is not a compatibility test.
Any required initialization package should be obtained for the ordered model. No driver IC is specified, so firmware or register requirements must not be inferred from another 400 × 1280 panel.
Backlight and Power Data Required
The backlight is identified as WLED with 24 white LEDs. This does not define the string arrangement, forward voltage, operating current, driver input, enable logic, dimming method or lifetime grade. Engineering release requires model-specific panel and backlight electrical data.
Non-Touch Front-Panel Planning
The standard configuration is non-touch. Input can be provided through adjacent buttons, a rotary control or another qualified device. A touch version would require a separately engineered sensor, controller, interface, cover lens, bonding method and mechanical stack.
Mechanical Fit and Environmental Qualification
Active Area and Module Envelope
The active area is 59.4 × 190.08 mm, while the complete module measures 68.7 × 213.48 × 6.28 mm. An approved drawing should also define tolerances, support areas, connector position, FPC bend limits and component keep-outs before the enclosure is released.
FPC Routing and Structural Support
The FPC connection is positioned near the top edge. Routing should avoid sharp bends, compression and repeated movement. Because the panel is long and narrow, the enclosure should provide even support without twisting the glass or loading the active area.
Wide-Temperature Component Limits
The operating range is −20°C to +70°C, with storage from −30°C to +80°C. These are component limits, not finished-system qualification. The host board, backlight driver, front lens, adhesives and cables must also meet the target environment.
Applications for Industrial and Embedded Equipment
The Narrow Equipment Display Module is suited to machine-status areas, equipment menu strips, smart-appliance controls, embedded information bands and narrow industrial control panels. Its 400 × 1280 canvas is useful where vertical space is available but panel width is restricted.
The panel specification does not establish waterproofing, automotive grade, medical certification or direct outdoor suitability for the finished device.
Customization and Procurement
Project review can cover FPC orientation, pin definition, interface matching, cover lens, optical treatment, bonding, enclosure adaptation, mounting, separate touch development, branding and packaging.
Custom configurations are generally reviewed from 500 pieces, subject to tooling, material availability and the requested specification. Sample and standard-module quantities are confirmed separately. A two-piece minimum order and paid-sample route are available in the current commercial configuration, but terms should be reconfirmed.
Procurement Checklist
Confirm the approved drawing and datasheet; native 400 × 1280 timing; MIPI lane count and mode; full 40-pin assignment; signal and power voltages; initialization package; FPC pitch, contact side and orientation; WLED voltage, current, topology, enable and dimming; active area; complete module fit; front-lens transmission and reflection; touch plan; temperature targets; sample criteria; quantity and annual demand.


FAQ
About 7.84 Inch Narrow Equipment Display Module
What must be checked before connecting the 40-pin MIPI host?
How should content be prepared for the 400 × 1280 display area?
Is 450 cd/m² sufficient behind a front lens?
Does the standard module include touch?
Which dimensions control enclosure release?
Freya Yang