10.1 Inch Industrial Capacitive PCAP Touch Panel Module for HMI

Product Gallery
Key Specs

Model P/N

HS101037Y0130A

Size

10.1″

Resolution

1024×600

Brightness

450 (Typ.)(cd/m²)

Viewing Angle

6 o’clock preferred viewing direction

Connector Type

MIPI, 30-pin

Operating Temp

-20 ~
70 °C

Overall(mm)

235(W)×
143(H)×
6.55(D)
Upgrade Options (OEM/ODM)

huisoar

HS101037Y0130A

General Features

Brand

huisoar

Panel Size (inch)

10.1"

Model P/N

HS101037Y0130A

Resolution

1024×600

Brightness (nits)

450 cd/m² (Typ.)

Viewing Angle

6 o’clock preferred viewing direction

Response Time

12ms

Overall (mm)

235(W)×
143(H) ×
6.55(D) mm

Active Area (mm)

222.72 × 125.28 mm

Refresh Rate

60Hz

Display Colors

16.7M

Panel Type

tft-lcd, lcm

Connector Type

MIPI, 30-pin

Operating Temp

-20 ~
70 °C

Touchscreen Type

Capacitive selected configuration

Storage Temp

−30°C to +80°C

Work Mode

Normally black, transmissive

I/O Interface

MIPI display interface; touch-control interface requires confirmation

Designed For

Industrial / handheld-device integration; regulated-device qualification required where applicable

10.1 Inch Industrial Capacitive PCAP Touch Panel Module for HMI

An Industrial Capacitive PCAP Touch Panel Module gives equipment designers a practical 10.1-inch interface platform when a landscape TFT, MIPI image connection, and touch interaction need to be combined in a compact assembly. The display uses a 1024 × 600 pixel format, a 222.72 × 125.28 mm active area, and 450 cd/m² typical luminance. Its TN transmissive normally-white optical mode and 6 o’clock preferred viewing direction make installation orientation an important part of product design.

Key Specifications

SpecificationConfirmed value
Display size10.1 inches
Resolution1024 × 600 pixels
Panel technologyTN TFT LCD
Display modeTransmissive, normally white
Viewing direction6 o’clock
Active area222.72 × 125.28 mm
LCD outline235 × 143 × 4.55 mm
Typical luminance450 cd/m²
Minimum luminance400 cd/m²
Luminance uniformity75% minimum / 80% typical
Display interfaceMIPI
Connector30-pin
Backlight42-chip white LED
Backlight reference18 V typical; 16.8–19.8 V; 140 mA fixed
Operating temperature−20°C to +70°C
Storage temperature−30°C to +80°C
Touch configurationCapacitive touch

1024 × 600 Landscape UI for Equipment Interfaces

Wide-format layout for controls and status information

The 1024 × 600 resolution provides a practical landscape workspace for menus, measurement values, status graphics, control buttons, and guided operating steps. A 10.1-inch diagonal offers more usable interface area than smaller embedded panels while remaining suitable for machine terminals, portable instruments, and compact operator equipment.

The 222.72 × 125.28 mm active area defines the visible image window. Housing, bezel, and cover design should instead be released against the complete mechanical envelope of the final LCD-and-touch assembly.

TN viewing direction must match the operator position

This TFT uses a 6 o’clock preferred viewing direction rather than a full-view IPS structure. The installation angle and operator eye position should therefore be evaluated during prototype testing before the enclosure orientation is frozen.

Industrial Capacitive PCAP Touch Panel Module Integration

MIPI compatibility requires more than a matching 30-pin connector

The 30-pin MIPI connection is a major integration feature, but connector count alone does not establish compatibility. The host platform still needs the approved pin assignment, lane configuration, timing, signal voltage requirements, reset behavior, and FPC orientation for the ordered display revision.

A controller that supports another 30-pin MIPI panel should not automatically be treated as interchangeable. Qualification should begin with native 1024 × 600 timing and the complete electrical definition.

Capacitive touch requires separate electrical qualification

The Industrial Capacitive PCAP Touch Panel Module is positioned around a capacitive-touch configuration, but the touch-controller model, electrical interface, touch-point count, supply voltage, and touch pinout are not defined in the current configuration data.

Those details should be confirmed independently from the TFT MIPI path. The final front-window and enclosure design should also use the combined LCD-and-touch drawing rather than relying only on the bare LCD outline.

450 cd/m² Typical Luminance for Professional Equipment

Use minimum and typical luminance correctly

The optical specification gives 400 cd/m² minimum and 450 cd/m² typical luminance. Procurement can therefore use 450 cd/m² as the nominal specification while retaining 400 cd/m² as the minimum acceptance reference.

This luminance range fits controlled-light industrial interiors, service equipment, professional instruments, and similar installations. It should not be described as sunlight readable without finished-system testing that considers the touch cover, bonding stack, reflections, viewing direction, and actual lighting environment.

White LED backlight requires its own drive design

The backlight uses 42 white LED chips. Its electrical reference is 18 V typical, with a 16.8–19.8 V forward-voltage range and 140 mA fixed current.

These are backlight values rather than TFT logic-supply values. The system designer should confirm the backlight-driver scope, dimming method, and electrical implementation for the final assembly.

Mechanical Fit for Portable and Embedded Equipment

The LCD outline is 235 × 143 × 4.55 mm, with a 222.72 × 125.28 mm active area. The enclosure must additionally accommodate the capacitive-touch layer, FPC exits, connector clearance, bonding materials, and manufacturing tolerance.

For portable professional equipment, cable routing can be as important as LCD thickness. FPC bend regions should remain clear of housing features, and the final front opening should be checked against the approved assembly drawing.

Temperature Range and Application Boundaries

The operating range is −20°C to +70°C, with storage from −30°C to +80°C. These figures support professional embedded use but do not establish an IP rating, vibration class, finished outdoor rating, or regulated-device certification.

The module can be considered for industrial HMI panels, portable test and service equipment, equipment dashboards, compact control terminals, and other embedded operator interfaces after electrical, optical, mechanical, and environmental qualification. Regulated equipment requires the applicable finished-product qualification.

Customization and Order Configuration

Capacitive touch is the configuration emphasized for this module, while resistive and capacitive touch variants can be evaluated for different projects. Touch geometry, FPC design, connector definition, brightness, bonding, backlight, and mechanical adaptation should be reviewed against the target enclosure and processor platform.

Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability, and the requested specification. Sample and standard-module quantities are confirmed separately.

Procurement Checklist

Before approving the Industrial Capacitive PCAP Touch Panel Module, confirm the native 1024 × 600 timing; complete 30-pin MIPI pin assignment; lane mapping and voltage domains; FPC pitch, contact side, and orientation; exact capacitive-touch controller and interface; touch pinout and firmware requirements; 222.72 × 125.28 mm active area; 235 × 143 × 4.55 mm LCD outline; final combined touch-stack drawing; 400 cd/m² minimum and 450 cd/m² typical luminance; 6 o’clock viewing orientation; approved 16.8–19.8 V / 140 mA backlight requirement; operating and storage limits; sample criteria; quantity; and annual demand.

Application Scenarios

FAQ

About 10.1 Inch Industrial Capacitive PCAP Touch Panel Module

What must be checked before connecting a 30-pin MIPI host?

A 30-pin connector match is not sufficient to approve the connection. Confirm native 1024 × 600 timing, complete pin assignment, MIPI lane configuration, signal voltages, reset behavior, and FPC orientation for the exact panel revision. Compare the host-controller documentation with the approved display drawing before PCB release.

Does the MIPI connector also define the capacitive-touch interface?

The touch-control interface is not established by the MIPI designation alone. Treat the TFT image path and touch-control path as separate qualification items until the exact touch controller, bus, voltage, pinout, interrupt/reset requirements, and FPC definition are approved.

Which brightness figure should procurement use?

Use 450 cd/m² typical as the nominal luminance and 400 cd/m² minimum as the lower reference. Finished visibility still depends on the touch cover, bonding, reflections, viewing orientation, and ambient light.

How should the 6 o’clock viewing direction affect enclosure design?

Evaluate the operator eye line before freezing the display orientation. Because this is a TN panel with a 6 o’clock preferred direction, prototype evaluation should be performed in the actual installed position rather than only with the module flat on a bench.

What information is required to approve the capacitive-touch version?

Submit the target processor or controller, required touch interface, expected interaction behavior, cover-lens drawing, enclosure opening, cable routing, operating environment, and sample quantity. Engineering review should confirm the touch-controller route, pin definition, combined mechanical stack, alignment, and electrical integration before production approval.

Need a custom solution or samples?

Request Engineering Review For an Industrial Capacitive PCAP Touch Panel Module project, submit your host processor or controller, MIPI requirements, touch-interface preference, enclosure drawing, viewing orientation, target luminance, operating environment, sample quantity, and annual demand. Engineering review covers MIPI timing and pin compatibility, capacitive-touch controller requirements, LCD and touch mechanics, backlight drive, viewing-direction fit, optical-stack considerations, temperature limits, and feasible customization.
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.