10.1 Inch Wide Temp Sunlight Readable LCD Display for Industrial HMI

Product Gallery
Key Specs

Model P/N

HS101048N3

Size

10.1″

Resolution

1280×800

Brightness

1000 (Typ.)(cd/m²)

Viewing Angle

85°/85°/85°/85° (L/R/U/D)

Connector Type

LVDS, 40 pins, 8-bit

Operating Temp

-20 ~
70 °C

Overall(mm)

229.1(W)×
148.9(H)×
4.4(D)
Upgrade Options (OEM/ODM)

huisoar

HS101048N3

General Features

Brand

huisoar

Panel Size (inch)

10.1"

Model P/N

HS101048N3

Resolution

1280×800

Brightness (nits)

1000 cd/m² (Typ.)

Viewing Angle

85°/85°/85°/85° (L/R/U/D)

Contrast Ratio

800:1 (Typ.)

Response Time

8ms

Overall (mm)

229.1(W)×
148.9(H) ×
4.4(D) mm

Active Area (mm)

216.96 (W) × 135.6 (H) mm

Refresh Rate

60Hz

Display Colors

16.7M colors

Panel Type

tft-lcd, lcm

Connector Type

LVDS, 40 pins, 8-bit

Operating Temp

-20 ~
70 °C

Touchscreen Type

Without Touch

Storage Temp

−30°C to +80°C

Work Mode

Normally black, transmissive

Pixel Format

RGB Stripe

Operating Environment

Bright-ambient industrial / protected outdoor-facing integration after system qualification g(Typ./Max.)

Designed For

Tablets, industrial equipment, outdoor devices, vehicle displays, medical display equipment,Industrial HMI

10.1 Inch Wide Temp Sunlight Readable LCD Display for Industrial HMI

A Wide Temp Sunlight Readable LCD Display in a compact 10.1-inch format gives equipment designers 1000 cd/m² typical luminance, 1280 × 800 resolution, full-view IPS behavior, and a 40-pin 8-bit LVDS interface. The 216.96 × 135.6 mm active area fits landscape operator interfaces, while the 229.1 × 148.9 × 4.4 mm module outline supports thin embedded layouts. With −20°C to +70°C operation and −30°C to +80°C storage, the module suits industrial HMI and other bright-ambient equipment that needs a wider environmental window than ordinary office displays.

Product Summary

The panel uses a 1280 × 800 pixel layout and RGB Stripe arrangement, providing a 16:10 workspace for controls, diagrams, menus, alarms, and status data. Its 1000 cd/m² typical luminance provides more optical margin where ambient light is stronger than in a conventional indoor installation.

The module is a display component rather than a finished outdoor monitor. Final readability depends on the front stack, installation angle, reflected ambient light, enclosure design, and thermal conditions. The 1000 cd/m² panel rating should be validated behind the final cover stack under the intended site lighting. Optical-engineering guidance likewise treats panel luminance, reflections, glass treatment and bonding as parts of one readability system.

Compact WXGA format for operator interfaces

The 216.96 × 135.6 mm active area provides useful room for process values, charts, navigation, and status regions without moving to a larger mechanical envelope. Driving the panel at its native 1280 × 800 raster also avoids unnecessary scaling, so UI assets and controller timing should be prepared around that format.

1000 cd/m² luminance for bright-ambient equipment

Higher panel luminance helps near windows, under strong overhead lighting, or in protected outdoor-facing equipment. It does not remove reflection risk. Cover-glass transmission, surface treatment, an air gap or bonding layer, screen angle, and solar heat load can materially change the viewed result.

Key Specifications at a Glance

ParameterConfirmed specification
Size10.1 inches
Resolution1280 × 800 pixels
Active Area216.96 × 135.6 mm
Module Outline229.1 × 148.9 × 4.4 mm
Brightness1000 cd/m² typical
Panel Technologya-Si TFT-LCD, IPS full-view family
Viewing Angle85°/85°/85°/85° (L/R/U/D)
Contrast Ratio800:1 typical
Display Colors16.7M colors
Pixel ArrangementRGB Stripe
InterfaceLVDS, 8-bit
Connector40 pins
BacklightWLED
TouchNo touch
Operating Temperature−20°C to +70°C
Storage Temperature−30°C to +80°C

Bright-Ambient Optical Performance

The combination of 1000 cd/m² typical luminance, 800:1 typical contrast, and full-view IPS behavior gives the panel a strong starting point for bright industrial interfaces.

85°/85°/85°/85° full-view geometry

The 85°/85°/85°/85° viewing angles in the left, right, up, and down directions help when the operator is not centered directly in front of the panel. Bezel depth, cover-glass reflections, screen tilt, and enclosure geometry can still affect off-axis contrast.

Why the final cover stack still matters

Sunlight readability is a system-level optical result. A bright LCD can lose useful contrast when an untreated front window reflects the environment toward the viewer. For outdoor-facing or window-adjacent equipment, front glass, AG/AR treatment, the air gap or bonding approach, and thermal design should be evaluated together with panel luminance.

Integrating the Wide Temp Sunlight Readable LCD Display

The panel uses a 40-pin 8-bit LVDS interface, making electrical compatibility a primary design-in checkpoint. Connector count alone is not enough to approve another controller, cable, or replacement panel.

40-Pin 8-Bit LVDS host qualification

A matching 40-pin LVDS connector does not guarantee electrical, timing, pin-mapping, or cable compatibility. Before PCB or cable release, confirm native 1280 × 800 timing, complete pin assignment, LVDS mapping, connector pitch, contact side, cable orientation, panel power, and WLED drive requirements. LVDS pin definitions can vary across brands and models.

1280 × 800 native content planning

The native 16:10 raster provides more vertical workspace than 16:9 at similar width. It is useful for HMI pages with alarm banners, navigation rows, trend charts, or multiple control groups. Software teams should validate font size and icon density at the actual viewing distance.

Mechanical Integration and Enclosure Planning

The active area and module outline serve different purposes. The 216.96 × 135.6 mm active area defines the visible image region, while the 229.1 × 148.9 × 4.4 mm outline controls physical fit, support, clearance, and bezel planning.

Active area versus module outline

A front-window opening should be developed from the approved mechanical drawing rather than from active area alone. Connector clearance, cable bend radius, frame overlap, support points, and manufacturing tolerance sit outside the image region.

No-touch front-panel architecture

The standard configuration is non-touch, so interactive control requires another input method or a separately specified touch assembly. If touch is needed, cover dimensions, interface, optical losses, bonding method, environmental behavior, and final thickness require separate qualification.

Wide-Temperature Operation for Industrial Equipment

This Wide Temp Sunlight Readable LCD Display operates from −20°C to +70°C and stores from −30°C to +80°C. Those ranges suit equipment that may experience broader temperature changes during use, shipping, or warehousing.

The operating range defines powered use; storage addresses non-operating exposure. The −20°C to +70°C operating range does not establish waterproofing or an IP rating. Sealing, condensation control, UV exposure, vibration, and thermal management remain system-level responsibilities.

Operating and storage ranges serve different purposes

Do not use the storage range as the powered operating range. At temperature extremes, the complete system should be checked for backlight behavior, controller timing, cable materials, enclosure expansion, condensation risk, and heat dissipation.

Recommended Application Direction

Industrial HMI and field-control interfaces

The module fits machine HMIs, process-control terminals, factory information interfaces, field service panels, and equipment status displays that need compact 10.1-inch geometry with high luminance and broad viewing.

Bright commercial and service equipment

The same 1000 cd/m² luminance and 1280 × 800 resolution can support protected information terminals, service equipment, window-adjacent interfaces, and outdoor-visible displays inside a properly engineered enclosure. Direct exposure, ingress protection, and regulated-use qualification remain finished-system responsibilities.

Procurement Checklist

Before sample approval, confirm the production revision, native 1280 × 800 timing, complete 40-pin 8-bit LVDS definition, connector orientation, panel power, WLED voltage/current/control requirements, 216.96 × 135.6 mm active area, 229.1 × 148.9 × 4.4 mm outline, 1000 cd/m² luminance tolerance, 800:1 contrast, 85°/85°/85°/85° viewing, 16.7M color mode, non-touch status, temperature limits, front-window optical stack, environmental requirements, sample quantity, and annual demand.

Application Scenarios

FAQ

About 10.1 Inch Wide Temp Sunlight Readable LCD Display

What must be checked before replacing another 40-pin LVDS display?

Compare native 1280 × 800 timing, LVDS mapping, complete 40-pin assignment, connector orientation, panel power, and backlight requirements. Another 40-pin panel can still differ electrically or mechanically. Test the intended controller and cable with a sample before approving a production replacement.

Is 1000 cd/m² sufficient behind the final cover glass?

It is a high-brightness starting point, but the assembled result depends on the optical stack. Cover glass, air gaps, coatings, or bonding can change transmission and reflection. Evaluate the assembled equipment under target lighting and viewing angles before approving direct-sun or window-facing performance.

Can HDMI, eDP, MIPI, or USB connect directly to this panel?

The confirmed panel interface is 40-pin 8-bit LVDS. Hosts using HDMI, eDP, MIPI, USB, or another signal standard require suitable conversion or controller hardware matched to native timing, pin mapping, power, and backlight control.

What is the difference between operating and storage temperature?

The panel operates from −20°C to +70°C and stores from −30°C to +80°C when unpowered. The wider storage range should not be used as a powered-use limit. System qualification should also cover enclosure temperature, backlight heat, cable materials, and condensation.

Which dimensions should control enclosure release?

Use the approved module drawing. The active area is 216.96 × 135.6 mm, while the LCD outline is 229.1 × 148.9 × 4.4 mm. Enclosure planning must also account for frame overlap, connector clearance, cable routing, tolerances, and any added cover stack.

Need a custom solution or samples?

Request a Sample and Engineering Review For a Wide Temp Sunlight Readable LCD Display sample review, submit your host/controller platform, native timing, 40-pin LVDS pinout or cable requirement, enclosure drawing, front-window stack, target lighting, operating environment, sample quantity, and forecast demand. Engineering review covers LVDS compatibility, panel and backlight power requirements, mechanical fit, optical performance, temperature boundaries, front-stack design, and project-specific adaptation before production approval.
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.