19 Inch 1500 Nits Sunlight Readable TFT Module for Security Consoles

Product Gallery
Key Specs

Model P/N

HS190ETN-GE15

Size

19″

Resolution

1280×1024

Brightness

1500 (Typ.)(cd/m²)

Viewing Angle

85°/85°/80°/80° typical at CR ≥ 10

Connector Type

30-pin, two-channel, 8-bit LVDS

Operating Temp

-20 ~
70 °C

Overall(mm)

396(W)×
324(H)×
11.7(D)
Upgrade Options (OEM/ODM)

huisoar

HS190ETN-GE15

General Features

Brand

huisoar

Panel Size (inch)

19"

Model P/N

HS190ETN-GE15

Resolution

1280×1024

Brightness (nits)

1500 cd/m² (Typ.)

Viewing Angle

85°/85°/80°/80° typical at CR ≥ 10

Contrast Ratio

1000:1 typical

Response Time

3/7 ms typical, Tr/Td

Overall (mm)

396(W)×
324(H) ×
11.7(D) mm

Active Area (mm)

376.32 × 301.056 mm

Refresh Rate

60Hz

Display Colors

16.7M colors, 73% NTSC

Panel Type

tft-lcd, lcm

Connector Type

30-pin, two-channel, 8-bit LVDS

Surface Treatment

3H hard coating

Operating Temp

-20 ~
70 °C

Touchscreen Type

Optional Custom Touch Screen

Storage Temp

−30°C to +80°C

Work Mode

Normally Black, Transmissive

Pixel Format

RGB vertical stripe, 86 PPI

Input Voltage (V)

5.0 V typical

Weight (g)

840 g(Typ./Max.)

Operating Environment

Bright indoor, protected outdoor-facing or industrial equipment after system qualification g(Typ./Max.)

Designed For

Security consoles, industrial equipment, embedded systems and outdoor-facing displays

19 Inch 1500 Nits Sunlight Readable TFT Module for Security Consoles

This 19-inch SXGA module combines a 1500 cd/m² target, dual-channel LVDS, a 5:4 workspace and wide-temperature operation for bright equipment interfaces.

Product Summary

The 1500 Nits Sunlight Readable TFT Module is a 19-inch a-Si TFT-LCD component for security monitoring, embedded equipment and industrial interfaces that need more luminance than a standard indoor display. Its native 1280 × 1024 raster provides a balanced 5:4 workspace for camera grids, alarm panels, status menus and control functions.

The module combines a 376.32 × 301.056 mm active area with a 396 × 324 × 11.7 mm physical envelope. A 30-pin, two-channel, 8-bit LVDS interface supports native display integration, while the listed 5.0 V panel input and 60 Hz frame rate provide clear starting points for controller and power-system qualification.

Key Specifications

ParameterConfirmed value
Screen size19 inches
Resolution1280 × 1024 pixels, SXGA, 86 PPI
Native geometry5:4
Active area376.32 × 301.056 mm
Module envelope396 × 324 × 11.7 mm
Product luminance1500 cd/m²
Contrast ratio1000:1 typical
Viewing sequence85°/85°/80°/80° typical at CR ≥ 10
Response time3/7 ms typical, Tr/Td
Display colors16.7M colors, 73% NTSC
Frame rate60 Hz
Signal interface30-pin, two-channel, 8-bit LVDS
Panel input5.0 V typical
Weight840 g
Surface3H hard coating
Operating temperature−20°C to +70°C
Storage temperature−30°C to +80°C

5:4 SXGA Workspace for Security Consoles

Native Content Layout

The 1280 × 1024 raster provides additional vertical workspace compared with widescreen formats. This can be useful for surveillance camera lists, event logs, alarm histories and equipment menus that need persistent navigation or status areas.

Native output should be used whenever possible. Scaling a different aspect ratio into the panel can introduce softened text, unused borders or distorted interface geometry.

5:4, Not 4:3

The native pixel ratio and active-area dimensions define a 5:4 display. Software layouts, enclosure openings and replacement-panel comparisons should therefore be prepared for 5:4 geometry.

A project based on a 4:3 assumption may produce incorrect content scaling or mechanical-window proportions. The approved UI and controller timing should use the confirmed 1280 × 1024 canvas.

1500 cd/m² Optical Planning

Validate the Finished Front Stack

A 1500 cd/m² module can support equipment exposed to strong ambient light, but the installed result also depends on front-window reflection, tint, surface contamination, bonding and viewing direction.

Test the complete stack using the planned cover material and enclosure. Security-console evaluation should include dark camera scenes, white status screens, small text and high-contrast warning graphics under representative lighting. Optical bonding and anti-reflective treatments can reduce internal reflection, but they must be evaluated as separate assembly options.

Lock the Ordered Luminance

The purchasing specification should identify the nominal 1500 cd/m² output, tolerance, test location, backlight condition and dimming requirement. This prevents a broader product-family range from being mistaken for the exact ordered configuration.

Luminance selection affects backlight power, heat generation and optical-stack performance. The approved configuration should be tested before cabinet and thermal release.

Integrating the 1500 Nits Sunlight Readable TFT Module

30-Pin LVDS Compatibility

A physically matching connector does not prove electrical compatibility. Confirm the complete pin assignment, two-channel mapping, 8-bit convention, connector orientation, voltage levels, native timing and cable requirements.

Controller qualification should include pixel clock, horizontal and vertical timing, data mapping and the selected LVDS convention. Display-compatibility guidance from module manufacturers likewise requires checking pin functions, panel voltage and backlight voltage rather than relying on connector shape alone.

5.0 V Panel Rail and Backlight Boundary

The listed 5.0 V value applies to the panel input. It does not define the complete LED-backlight electrical system.

Obtain backlight voltage, current, enable logic, dimming control, startup behavior and driver details before releasing the power design. The product description lists a built-in LED driver, but its electrical limits and relationship to the host controller still require approved documentation.

Mechanical and Environmental Release

Active Area and Overall Size

The 376.32 × 301.056 mm active area defines the visible pixel region. The 396 × 324 × 11.7 mm envelope controls cabinet clearance and module fit.

Mechanical release should also confirm mounting points, connector keep-outs, edge-loading limits, cable bend radius and front-window overlap. The active area must not be substituted for the complete module outline.

Weight and Temperature

The module weighs 840 g. Mounting support should prevent glass twist, concentrated edge pressure and cable loading.

The listed operating range is −20°C to +70°C, with storage from −30°C to +80°C. These values define panel-temperature limits; they do not establish waterproofing, condensation resistance, corrosion protection or a finished enclosure rating.

Application Fit

Security and Surveillance Consoles

The 1500 Nits Sunlight Readable TFT Module can be evaluated for security-monitoring consoles, surveillance interfaces and control stations that need a 5:4 SXGA workspace. The format supports camera grids, system alarms and persistent side menus without requiring a wide consumer-style screen.

The 1000:1 typical contrast ratio, 16.7M colors and listed 85/85/80/80 viewing sequence provide a basis for visual qualification, but the final operator position should be tested because the direction order is not defined.

Industrial and Outdoor-Facing Equipment

The module may also suit embedded control equipment, protected outdoor-facing kiosks and industrial interfaces. Its wide temperature limits and 3H hard coating provide useful component-level selection data.

Touch capability, front glass, optical bonding and enclosure protection should be treated as separate project requirements. They are not automatically established by the bare module.

Customization and Procurement

Project review may include brightness confirmation, LVDS cable and controller matching, front glass, anti-glare or anti-reflective treatment, optical bonding, touch integration, enclosure adaptation, mounting and thermal planning.

Product-family options such as IP-rated enclosures, alternate system connectors, wide-voltage power regulation and embedded operating systems become specifications only when they are included in an approved project configuration.

Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability and the requested specification. Samples and standard-module quantities are confirmed separately.

Procurement Checklist and FAQ

Procurement Checklist

  • Approved HS190ETN-GE15 and RS190ETN-GE15 revision
  • Confirmed 1500 cd/m² output and tolerance
  • Native 1280 × 1024 timing at 60 Hz
  • 5:4 interface layout
  • Complete 30-pin LVDS assignment
  • Two-channel and 8-bit mapping convention
  • Connector orientation and cable drawing
  • 5.0 V panel-rail current
  • LED-backlight voltage and current
  • Backlight enable and dimming logic
  • 376.32 × 301.056 mm active area
  • 396 × 324 × 11.7 mm module envelope
  • 840 g structural load
  • Front-window transmission and reflection targets
  • Viewing-angle direction order
  • Touch requirement
  • Operating and storage limits
  • Sample acceptance criteria
  • Quantity and annual demand
Application Scenarios

FAQ

About 19 Inch 1500 Nits Sunlight Readable TFT Module

What must be checked before connecting a 30-pin LVDS controller?

Confirm the complete pinout, two-channel mapping, 8-bit convention, panel voltage, connector orientation and native 1280 × 1024 timing. A matching connector alone does not establish compatibility. The controller and cable should be tested together at 60 Hz before production release.

Does 1500 cd/m² guarantee readability behind the final cover?

No. The panel output is only one part of installed readability. Cover transmission, reflections, bonding, ambient-light direction and enclosure temperature can change the final result. Test the selected panel behind the actual front window under representative lighting.

How should 1280 × 1024 content be prepared?

Prepare content natively in a 5:4 canvas. Using a 4:3 or widescreen assumption can create scaling, border or geometry problems. Validate small text, camera grids, alarm indicators and menu layouts on the physical sample.

Which dimensions control enclosure release?

Use the 396 × 324 × 11.7 mm overall envelope for cabinet clearance and the 376.32 × 301.056 mm active area for the visible image window. Obtain mounting points and connector keep-outs before finalizing the enclosure.

How should the viewing and response values be interpreted?

The viewing sequence is listed as 85/85/80/80 at CR ≥ 10, but its direction order requires confirmation. Response is listed as 3/7 ms typical for Tr/Td. Evaluate both values with representative camera content and the intended operator position.

Need a custom solution or samples?

Request Engineering Review Submit These Requirements Send the approved model revision, brightness target, controller model, native timing, complete LVDS definition, power architecture, enclosure and front-window drawings, operator viewing position, touch requirement, sample quantity and annual demand. Engineering Review Outcome Engineering review for the 1500 Nits Sunlight Readable TFT Module covers LVDS compatibility, native 5:4 content, panel and backlight power, optical-stack performance, mechanics, temperature limits, touch integration and sample-acceptance criteria.
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.