7.84 Inch Narrow Equipment Display Module for Control Panels

Product Gallery
Key Specs

Model P/N

HS078C8813M

Size

7.84″

Resolution

400×1280

Brightness

450 (Typ.)(cd/m²)

Viewing Angle

80°/80°/80°/80° left/right/up/down

Connector Type

MIPI 40 pins

Operating Temp

-20 ~
70 °C

Overall(mm)

68.7(W)×
213.48(H)×
6.28(D)
Upgrade Options (OEM/ODM)

huisoar

HS078C8813M

General Features

Brand

huisoar

Panel Size (inch)

7.84"

Model P/N

HS078C8813M

Resolution

400×1280

Brightness (nits)

450 cd/m² (Typ.)

Viewing Angle

80°/80°/80°/80° left/right/up/down

Contrast Ratio

900:1 typical

Response Time

10ms

Overall (mm)

68.7(W)×
213.48(H) ×
6.28(D) mm

Active Area (mm)

59.4 × 190.08 mm

Refresh Rate

60Hz

Bezel Opening

59.4 × 190.08 mm

Display Colors

16.7M colors

Panel Type

tft-lcd, lcm

Connector Type

MIPI 40 pins

Operating Temp

-20 ~
70 °C

Touchscreen Type

Optional

Storage Temp

−30°C to +80°C

Work Mode

IPS, normally black

Control Type

External matched MIPI display host/controller required

Operating Environment

Industrial and embedded equipment after system-level qualification g(Typ./Max.)

Designed For

Portable industrial devices, consumer tablets, smart terminals, handheld monitors, narrow industrial control panels, machine-status displays, equipment menu strips, embedded information bands, and compact embedded display systems.

7.84 Inch Narrow Equipment Display Module for Control Panels

Its 400 × 1280 portrait canvas, 450 cd/m² IPS optics and 40-pin MIPI connection support narrow industrial control and status interfaces.

Product Summary

The Narrow Equipment Display Module is a 7.84-inch a-Si TFT-LCD component for equipment that needs a tall visual area rather than a conventional widescreen panel. Its 59.4 × 190.08 mm active area can present alarms, operating states, menu lists, process values and segmented graphics within a slim opening.

The confirmed configuration combines 400 × 1280 pixels, 450 cd/m² typical luminance, IPS full viewing, a 900:1 typical contrast ratio and 16.7M colors. The native display connection is MIPI with 40 pins, while the standard module is non-touch.

A 40-pin MIPI connector does not establish lane, timing, voltage or pin compatibility. Native 400 × 1280 content avoids unnecessary scaling. The 450 cd/m² panel rating must be evaluated behind the final front lens under the intended lighting.

Key Specifications at a Glance

ItemConfirmed value
Screen size7.84 inches
Resolution400 × 1280 pixels
Panel constructiona-Si TFT-LCD, IPS family
Active area59.4 × 190.08 mm
Module dimensions68.7 × 213.48 × 6.28 mm
Luminance450 cd/m² typical
Contrast ratio900:1 typical
Viewing angle80°/80°/80°/80° left/right/up/down
Display colors16.7M colors
Display interfaceMIPI, 40 pins
BacklightWLED, 24 white LEDs
Touch statusNon-touch
Operating temperature−20°C to +70°C
Storage temperature−30°C to +80°C

Tall 400 × 1280 Layout for Narrow Control Panels

Native Portrait UI Planning

Design the interface specifically for 400 × 1280 pixels. Suitable layouts include vertically stacked status blocks, machine-state lists, guided operating steps and narrow information bands. Establish text size, line spacing, icon dimensions and safe margins at the actual viewing distance rather than rotating or cropping a standard landscape interface.

IPS Viewing for Side-Angle Readability

The 80°/80°/80°/80° viewing angles support equipment doors, upright consoles and shared status panels that may be viewed off center. Final performance also depends on the front lens, air gap, tint, surface reflection and mounting angle, so these factors should be assessed with an assembled sample.

450 cd/m² Controlled-Light Visibility

The fixed luminance statement is 450 cd/m² typical. It is suitable for evaluation in indoor industrial spaces and controlled-light equipment, but it should not be converted into a sunlight-readable claim. Optical review should use the intended lens material, printing, coating or bonding stack and the real ambient-light target.

Narrow Equipment Display Module Integration

40-Pin MIPI Host Qualification

Confirm the MIPI lane configuration, operating mode, pixel format, video timing, clock requirements, voltage rails, complete 40-pin assignment, reset and control signals, and FPC contact orientation. Pin count alone is not a compatibility test.

Any required initialization package should be obtained for the ordered model. No driver IC is specified, so firmware or register requirements must not be inferred from another 400 × 1280 panel.

Backlight and Power Data Required

The backlight is identified as WLED with 24 white LEDs. This does not define the string arrangement, forward voltage, operating current, driver input, enable logic, dimming method or lifetime grade. Engineering release requires model-specific panel and backlight electrical data.

Non-Touch Front-Panel Planning

The standard configuration is non-touch. Input can be provided through adjacent buttons, a rotary control or another qualified device. A touch version would require a separately engineered sensor, controller, interface, cover lens, bonding method and mechanical stack.

Mechanical Fit and Environmental Qualification

Active Area and Module Envelope

The active area is 59.4 × 190.08 mm, while the complete module measures 68.7 × 213.48 × 6.28 mm. An approved drawing should also define tolerances, support areas, connector position, FPC bend limits and component keep-outs before the enclosure is released.

FPC Routing and Structural Support

The FPC connection is positioned near the top edge. Routing should avoid sharp bends, compression and repeated movement. Because the panel is long and narrow, the enclosure should provide even support without twisting the glass or loading the active area.

Wide-Temperature Component Limits

The operating range is −20°C to +70°C, with storage from −30°C to +80°C. These are component limits, not finished-system qualification. The host board, backlight driver, front lens, adhesives and cables must also meet the target environment.

Applications for Industrial and Embedded Equipment

The Narrow Equipment Display Module is suited to machine-status areas, equipment menu strips, smart-appliance controls, embedded information bands and narrow industrial control panels. Its 400 × 1280 canvas is useful where vertical space is available but panel width is restricted.

The panel specification does not establish waterproofing, automotive grade, medical certification or direct outdoor suitability for the finished device.

Customization and Procurement

Project review can cover FPC orientation, pin definition, interface matching, cover lens, optical treatment, bonding, enclosure adaptation, mounting, separate touch development, branding and packaging.

Custom configurations are generally reviewed from 500 pieces, subject to tooling, material availability and the requested specification. Sample and standard-module quantities are confirmed separately. A two-piece minimum order and paid-sample route are available in the current commercial configuration, but terms should be reconfirmed.

Procurement Checklist

Confirm the approved drawing and datasheet; native 400 × 1280 timing; MIPI lane count and mode; full 40-pin assignment; signal and power voltages; initialization package; FPC pitch, contact side and orientation; WLED voltage, current, topology, enable and dimming; active area; complete module fit; front-lens transmission and reflection; touch plan; temperature targets; sample criteria; quantity and annual demand.

Application Scenarios

FAQ

About 7.84 Inch Narrow Equipment Display Module

What must be checked before connecting the 40-pin MIPI host?

Confirm lane configuration, operating mode, pixel format, native timing, voltage rails, complete pin assignment, reset and control signals, FPC orientation and any initialization package. The same pin count does not prove compatibility. Submit the host specification and approved module documentation for engineering review before powering a sample.

How should content be prepared for the 400 × 1280 display area?

Create the interface at the native portrait raster and validate it within the 59.4 × 190.08 mm active area. Vertically stacked information, status lists and guided controls use the format more effectively than a cropped landscape screen. Check text size, icon scale and margins on the real panel.

Is 450 cd/m² sufficient behind a front lens?

It can suit indoor and controlled-light equipment, but the result depends on lens transmission, reflection, printing, tint and viewing geometry. Evaluate a representative front stack under the actual ambient-light target. The panel value alone does not justify a sunlight-readable claim.

Does the standard module include touch?

No. The confirmed configuration is non-touch. Adding interaction requires a separately selected sensor, controller, interface, cover lens and bonding structure. The additional stack can change optical transmission, thickness and bezel geometry, so the complete assembly must be qualified.

Which dimensions control enclosure release?

Use 68.7 × 213.48 × 6.28 mm as the confirmed module envelope and 59.4 × 190.08 mm as the active image area, but obtain the approved drawing before release. It must also define tolerances, FPC location, bend limits, support zones and component keep-outs.

Need a custom solution or samples?

Request a Technical Review Submit: model documentation, host processor, native timing, MIPI lane and mode requirements, complete 40-pin mapping, power plan, initialization package, enclosure drawing, front-lens stack, touch requirement, sample quantity and annual demand for the Narrow Equipment Display Module. Review outcome: engineering evaluates compatibility, initialization, panel and backlight power, FPC routing, optics, mechanical fit, environmental limits, touch development and customization feasibility.
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.