Freya Yang
+86 18318948097
+852 62667476
Custom 10.1 Inch MIPI Industrial Touch Screen Display Module for HMI
Model P/N
Size
Resolution
Brightness
Viewing Angle
Connector Type
Operating Temp
Overall(mm)
huisoar
HS101BH061-01A
Brand
Panel Size (inch)
Model P/N
Resolution
Brightness (nits)
Viewing Angle
Contrast Ratio
Response Time
Overall (mm)
Active Area (mm)
Refresh Rate
Display Colors
Panel Type
Connector Type
Operating Temp
Touchscreen Type
Storage Temp
Work Mode
Pixel Format
Input Voltage (V)
Operating Environment
Designed For
Custom 10.1 Inch MIPI Industrial Touch Screen Display Module for HMI
A portrait 800×1280 IPS module with 40-pin MIPI input, 250 cd/m² typical luminance, and optional capacitive touch integration.
The MIPI Industrial Touch Screen Display Module is a custom integration route built around a 10.1-inch IPS TFT-LCD base panel. It combines an 800×1280 portrait raster, 135.36 × 216.576 mm active area, 40-pin MIPI connection, and a slim 143.0 × 228.6 × 2.6 mm module outline. The standard display is supplied without confirmed touch hardware; a capacitive touch panel can be engineered as a separate project configuration.
Product Summary
This 10.1-inch display is designed for embedded HMI projects that need a portrait interface, compact depth, wide viewing performance, and a direct MIPI display path. The IPS normally-black panel provides an 800:1 typical contrast ratio, a 20 ms typical Tr+Tf response time, and a raw 80°/80°/80°/80° typical viewing-angle sequence. Direction order should be verified against the approved specification before mechanical orientation is released.
The 250 cd/m² typical luminance is intended primarily for indoor or controlled-light equipment. It should not be described as sunlight readable without finished-stack optical testing.
Key Specifications at a Glance
| Parameter | Confirmed value |
|---|---|
| Display size | 10.1 inches |
| Resolution | 800 × 1280 pixels |
| Panel type | IPS TFT-LCD, normally black |
| Active area | 135.36 × 216.576 mm |
| Module outline | 143.0 × 228.6 × 2.6 mm |
| Pixel pitch | 0.1692 × 0.1692 mm |
| Luminance | 250 cd/m² typical |
| Viewing angle | 80°/80°/80°/80° typical; direction order to confirm |
| Contrast ratio | 800:1 typical |
| Response time | 20 ms typical, Tr+Tf |
| Display interface | MIPI, 40-pin connector |
| Backlight | 28 white LEDs, 4S7P |
| Backlight electrical reference | 12.2 V / 140 mA |
| Backlight life | 30,000 hours minimum |
| Operating temperature | −20°C to +70°C |
| Storage temperature | −30°C to +80°C |
| Touch status | Optional capacitive touch-panel customization |
Portrait 800×1280 Interface Planning
Native portrait UI layout
The 800×1280 raster supports vertically organized menus, process steps, alarm lists, recipes, service instructions, and data-entry screens. UI assets should be prepared for the native portrait orientation rather than scaled from a landscape layout. The 0.1692 × 0.1692 mm pixel pitch provides square pixels, simplifying icon, font, and grid alignment.
Active area versus module outline
The 135.36 × 216.576 mm active area defines the visible pixel region. The 143.0 × 228.6 × 2.6 mm module outline defines the LCD mechanical envelope before any cover lens, touch sensor, adhesive, bracket, gasket, or enclosure feature is added. These dimensions serve different design functions and should not be interchanged in a housing drawing.
MIPI Industrial Touch Screen Display Module Integration
Verify the complete 40-pin definition
A matching 40-pin connector does not guarantee MIPI compatibility. The host must be checked for lane configuration, timing, voltage levels, reset behavior, connector pitch, contact side, pin assignment, FPC orientation, and required command or initialization data. The approved module revision should control the final interface package.
Keep display and touch paths separate
The MIPI connection is the LCD display path. An optional capacitive touch panel requires its own controller, communication interface, power rail, FPC, firmware, and mechanical stack. These touch details are not established by the LCD’s 40-pin MIPI connector and must be specified for the selected custom assembly.
Qualify the backlight driver
The backlight is identified as 28 white LEDs in a 4S7P arrangement with a 12.2 V / 140 mA electrical reference. The host or display board must provide a suitable backlight-driver solution and confirm enable, dimming, current regulation, startup behavior, thermal margin, and connector routing. The listed 30,000-hour minimum life applies to the stated module reference and should be checked against the final operating profile.
Optical Performance in Controlled Lighting
The 250 cd/m² typical panel luminance is appropriate for indoor HMIs, equipment panels, and protected kiosks where ambient lighting is managed. Cover glass, touch sensors, air gaps, optical adhesive, anti-glare treatment, printed borders, and viewing geometry can change finished-system brightness and contrast. Optical approval should therefore use a representative sample with the intended front stack.
The 800:1 typical contrast ratio and normally-black IPS mode support clear status graphics, menus, and data presentation. The raw four-value viewing-angle sequence indicates wide-view performance, but the directional order must remain unassigned until confirmed by the final datasheet.
Mechanical and Environmental Qualification
Slim module for portrait enclosures
At 2.6 mm module thickness, the bare LCD supports compact enclosure design. The final depth will increase when a capacitive sensor, cover lens, bonding layer, protective window, frame, gasket, and mounting hardware are added. The lower FPC area and bend radius should remain clear of compression points and sharp enclosure edges.
Temperature limits are component limits
The display is specified for operation from −20°C to +70°C and storage from −30°C to +80°C. These values do not prove vibration resistance, ingress protection, condensation resistance, UV stability, or compliance with a regulated equipment standard. System-level environmental qualification remains the responsibility of the finished product design.
Recommended Applications
This configuration is a practical fit for portrait-oriented industrial HMIs, machine settings panels, production status terminals, indoor self-service interfaces, compact POS operator displays, smart-building controls, and test or service equipment. Selection should be based on MIPI host compatibility, controlled-light optical requirements, enclosure fit, and the required touch configuration.
The MIPI Industrial Touch Screen Display Module should not be treated as a finished monitor or panel PC. It does not establish an included media board, operating system, enclosure, IP rating, or external video input such as HDMI.
Customization Scope
Project review may cover capacitive touch integration, cover-lens dimensions and printing, surface treatment, optical or perimeter bonding, FPC geometry, connector definition, interface alternatives, backlight adjustment, enclosure fit, branding, and packaging. The standard panel remains a 250 cd/m² MIPI LCD with optional touch rather than a prequalified outdoor touchscreen.
Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability, and the requested specification. Sample and standard-module quantities are confirmed separately.
Procurement Checklist
Before sample approval, provide:
- host processor or display-controller model;
- complete MIPI lane, timing, mode, voltage, reset, and command requirements;
- required 40-pin connector and FPC orientation;
- panel and backlight power architecture;
- portrait UI and rotation requirements;
- enclosure, bezel, cover-lens, and bonding drawings;
- capacitive touch technology, controller, interface, and touch-point requirement;
- target luminance behind the finished front stack;
- operating environment and qualification requirements;
- sample quantity, annual demand, and production schedule.



FAQ
About Custom 10.1 Inch MIPI Industrial Touch Screen Display Module
What must be checked before replacing another 40-pin MIPI panel?
Is the optional capacitive touch panel included in the standard module?
Is 250 cd/m² sufficient behind a cover lens and touch sensor?
Can this display connect directly to HDMI, USB, LVDS, or eDP?
Which dimensions should control enclosure design?
What is the minimum order quantity (MOQ) for custom display modules with specific touch interfaces?
MOQ for custom display modules with specific touch interfaces is Typically, custom configurations may require a minimum order quantity that varies based on the touch panel type and volume. For a precise MOQ, please request a quote from our sales team, providing your target touch interface and annual volume.
What is the operating and storage temperature range, and are wide-temp options available (e.g., -30~85, -40~85°C)?
This module operates from -20°C to +70°C and stores from -30°C to +80°C. Wide-temperature options such as -30~85°C or -40~85°C are If your application requires extended temperature ranges, please confirm with our engineering team whether a custom variant can be supported.
What are the operating temperature ranges for your industrial LCD panels, especially for extended outdoor use?
For this industrial LCD panel, the operating temperature range is -20°C to +70°C, which is typical for indoor HMI use. For extended outdoor applications requiring wider temperature tolerance, please consult our engineering team to evaluate possible customizations or recommend a panel with a broader temperature range.
Can you customize the mechanical dimensions and mounting holes of a standard LCD panel to fit our specific enclosure design?
Yes, mechanical dimensions and mounting holes can be customized to fit your enclosure. This module is a custom integration route, and the outline dimensions can be adjusted based on your design. Please provide your mechanical drawings to our engineering team for feasibility assessment and to ensure proper fit.
What interface options are available (e.g., LVDS, eDP, MIPI) for your panels?
This specific model, the HuiSoar HS101BH061-01A, is configured with a 40-pin MIPI interface. MIPI is a common choice for embedded HMI applications due to its high-speed serial data transfer and reduced pin count. If you need a different interface, please contact us with your specifications so we can recommend or customize a suitable panel. Exact availability and lead times for alternative interfaces should be confirmed on request.