Freya Yang
+86 18318948097
+852 62667476
55 Inch Industrial Ultra Bright UHD Display Panel for Signage
Model P/N
Size
Resolution
Brightness
Viewing Angle
Connector Type
Operating Temp
Overall(mm)
huisoar
HS055UHD-R200
Brand
Panel Size (inch)
Model P/N
Resolution
Brightness (nits)
Viewing Angle
Contrast Ratio
Response Time
Overall (mm)
Active Area (mm)
Refresh Rate
Display Colors
Panel Type
Connector Type
Surface Treatment
Operating Temp
Touchscreen Type
Storage Temp
Work Mode
Pixel Format
Input Voltage (V)
Weight (g)
Operating Environment
Designed For
55 Inch Industrial Ultra Bright UHD Display Panel for Signage
This 55-inch 4K ADS panel combines a selected 2000 cd/m² output, 51-pin V-by-One input, and wide-temperature operation for high-ambient-light signage.
The Industrial Ultra Bright UHD Display Panel is a large-format LCD component for outdoor and window-adjacent signage systems that require native 3840 × 2160 content, wide-angle ADS performance, and a high-output backlight. Its 1209.6 × 680.4 mm active area supports detailed public information, advertising, route data, and branded media while maintaining a standard 16:9 UHD workspace.
This configuration is specified at 2000 cd/m². Final readability still depends on the cover glass, internal reflections, installation orientation, ambient light, solar load, and thermal design of the completed signage assembly.
A matching 51-pin connector does not guarantee V-by-One compatibility.
MEMC-related 120 Hz or 240 Hz wording does not establish a native refresh rate above the 60 Hz standard.
A bare LCD panel is not a weatherproof outdoor display without a qualified enclosure and cooling system.
Key Specifications
| Item | Confirmed value |
|---|---|
| Display size | 55 inches |
| Resolution | 3840 × 2160 pixels, UHD |
| Active area | 1209.6 × 680.4 mm |
| Panel mode | ADS, normally black, transmissive |
| Pixel arrangement | RGB vertical stripe |
| Selected luminance | 2000 cd/m² |
| Viewing angles | 89°/89°/89°/89° typical, L/R/U/D |
| Contrast ratio | 1200:1 typical |
| Display colors | 1.07B colors, 74% NTSC |
| Response time | 8 ms typical, G-to-G |
| Standard refresh rate | 60 Hz |
| Surface treatment | Anti-glare, 1% haze, 3H hard coating |
| Signal interface | V-by-One, 8 lanes, 51 pins |
| Panel input | 12.0 V typical |
| Backlight | WLED with LED driver |
| Listed backlight reference | 50,000 hours |
| Typical weight | 15.0 kg |
| Touch status | No touch |
| Operating temperature | −20°C to +70°C |
| Storage temperature | −30°C to +80°C |
UHD Content and Optical Planning
Native 3840 × 2160 Content
Native UHD input provides space for high-resolution photography, detailed maps, passenger information, pricing, schedules, safety notices, and multi-zone layouts. Driving the panel at its native raster avoids unnecessary scaling and helps preserve small text, fine lines, and image detail.
Controller selection should confirm the exact UHD timing, 60 Hz operation, color mapping, V-by-One lane requirements, and data rate. Matching only the diagonal size and resolution is not sufficient for interchangeability.
2000 cd/m² Behind the Finished Front Stack
The 2000 cd/m² panel output is intended for high-ambient-light installations. Finished performance should be measured after the cover glass, air gap or optical bonding, printed border, coatings, and enclosure are installed.
Cover transmission and reflection both affect visible contrast. Anti-reflective glass, optical bonding, shading, and enclosure orientation may improve results, but each treatment must be assessed against cost, serviceability, thermal behavior, and mechanical requirements.
Anti-Glare Surface and Wide Viewing
The front polarizer uses an anti-glare treatment with 1% haze and 3H hard coating. The panel also lists 89° viewing in the left, right, up, and down directions under the stated contrast criterion.
These values support large public-display layouts where viewers approach from different positions. Final viewing performance should still be checked behind the selected front glass and at the intended installation angle.
V-by-One Integration for the Industrial Ultra Bright UHD Display Panel
Eight-Lane 51-Pin Host Qualification
The display uses an eight-lane V-by-One signal interface through a 51-pin terminal. Engineering qualification should include:
- Native 3840 × 2160 timing
- Required lane count and data rate
- Lane and color mapping
- Complete 51-pin assignment
- Connector orientation
- Mating connector and cable definition
- Signal integrity over the selected cable length
- Controller-board firmware
- Panel enable and status signals
A controller designed for another 51-pin panel may use different mapping, voltage, timing, or firmware.
Panel and Backlight Power
The panel input is listed at 12.0 V typical. The WLED system includes an LED-driver reference, but the production package should still define backlight voltage, current, enable, dimming, protection, thermal limits, and cable requirements.
The panel supply and backlight system should be treated as separate electrical design areas. Do not release the power architecture from the 12.0 V panel value alone.
Refresh Rate and MEMC Interpretation
Native 60 Hz Operation
The standard panel rate is 60 Hz. This is the appropriate baseline for controller qualification, content testing, and system release.
The additional 120 Hz and 240 Hz descriptions refer to MEMC processing or panel-plus-backlight configurations. They should not be rewritten as an unconditional native 120 Hz or 240 Hz panel specification. Any enhanced motion mode requires a defined controller, backlight configuration, input format, and approved production documentation.
Mechanical and Environmental Integration
Active Area and Structural Planning
The 1209.6 × 680.4 mm active area defines the image region, not the complete panel envelope. Enclosure development additionally requires:
- Full outline dimensions
- Panel thickness
- Mounting and support locations
- Rear-component keep-outs
- Connector position
- Cable bend clearance
- Edge protection
- Service access
- Allowable structural loading
The 15.0 kg typical weight must be included in bracket, frame, transport, and service calculations. The display should not be supported only by the active-area or front-glass geometry.
Temperature and Solar Load
The component is specified for operation from −20°C to +70°C and storage from −30°C to +80°C. These panel limits do not replace finished-system thermal validation.
Outdoor and window-adjacent installations should assess direct solar loading, internal air temperature, backlight heat, controller heat, glass absorption, airflow, condensation, dust, humidity, and service conditions. Enclosure sealing and cooling must be engineered together rather than added independently.
Application Fit for Outdoor Signage
The Industrial Ultra Bright UHD Display Panel is suited to large-format projects such as:
- Outdoor advertising structures
- Retail window-adjacent signage
- Passenger-information boards
- Station and airport displays
- Public-information systems
- High-ambient-light menu and promotion panels
- Large industrial visualization equipment
- Smart-city information structures
The standard panel has no touch sensor, media player, protective glass, weatherproof housing, speakers, networking, or operating system. These elements require separate system integration.
Customization and Project Qualification
Project review may cover:
- Final luminance version
- V-by-One controller and cable
- Cover glass and printed border
- Anti-reflective, anti-glare, or anti-fingerprint treatment
- Air or optical bonding
- Optional touch overlay
- Enclosure and mounting structure
- Backlight and thermal management
- Environmental sealing
- Branding, labeling, and packaging
Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability, and the requested specification. Sample and standard-panel quantities are confirmed separately.
Procurement Checklist
- Confirm the assigned model and approved production reference.
- Lock one 2000 cd/m² luminance target and tolerance.
- Confirm native 3840 × 2160 timing at 60 Hz.
- Confirm V-by-One lane count, data rate, mapping, and complete 51-pin assignment.
- Obtain connector, mating-part, cable, and orientation drawings.
- Confirm the 12.0 V panel rail and allowable tolerances.
- Obtain WLED voltage, current, enable, dimming, and protection data.
- Confirm the 1209.6 × 680.4 mm active area.
- Obtain the complete panel outline and mounting drawing.
- Design structural support for the 15.0 kg typical load.
- Define cover-glass transmission, reflection, coatings, and bonding.
- State site orientation, lighting conditions, and solar exposure.
- Define the cooling, sealing, condensation, and service strategy.
- Confirm no-touch or custom touch-overlay requirements.
- State sample criteria, quantity, annual demand, and schedule.



FAQ
About 55 Inch Industrial Ultra Bright UHD Display Panel
What Must Be Checked Before Connecting a 51-Pin V-by-One Controller?
How Should the 2000 cd/m² Rating Be Evaluated Behind Cover Glass?
Do the 120 Hz and 240 Hz Statements Mean the Panel Is Natively 120 or 240 Hz?
Is This a Finished Outdoor Display?
What Must Be Locked Before Approving the Brightness Version?
Freya Yang
+86 18318948097





