Freya Yang
+86 18318948097
+852 62667476
12.3 Inch Wide Temperature 750 Nits Touch Display for Industrial HMI
Model P/N
Size
Resolution
Brightness
Viewing Angle
Connector Type
Operating Temp
Overall(mm)
huisoar
HS012302YH50D
Brand
Panel Size (inch)
Model P/N
Resolution
Brightness (nits)
Viewing Angle
Contrast Ratio
Response Time
Overall (mm)
Active Area (mm)
Refresh Rate
Bezel Opening
Display Colors
Panel Type
Connector Type
Operating Temp
Touchscreen Type
Storage Temp
Work Mode
Pixel Format
Operating Environment
Designed For
12.3 Inch Wide Temperature 750 Nits Touch Display for Industrial HMI
A Wide Temperature 750 Nits Touch Display is useful when an embedded HMI needs a panoramic 1920 × 720 interface, capacitive touch and a broader operating-temperature window. The 12.3-inch format provides a 292.608 × 109.728 mm active area in a 309.0 × 128.0 × 6.5 mm LCD body. With 750 cd/m² luminance, 2-port LVDS and operation from −30°C to +85°C, it fits industrial control interfaces and other professional embedded systems built around a long horizontal UI.
Product Summary
The 1920 × 720 raster provides room for status zones, alarms, trends and touch controls without requiring a tall display. Capacitive touch enables direct interaction, while the specified temperature range gives engineering teams a defined display-level window for environmental qualification.
Wide-Format 1920 × 720 Interface Layout
The 292.608 × 109.728 mm active area is well suited to machine dashboards and equipment interfaces with multiple horizontal information zones. Use the active area and approved front-window dimensions when planning the visible graphics region.
750-Nit Luminance with Extended-Temperature Operation
The 750 cd/m² luminance is a higher-brightness starting point for bright indoor and covered high-ambient installations. Final readability should still be tested with the real cover lens, reflections, bonding stack and installation angle.
Key Specifications
| Item | Confirmed value |
|---|---|
| Size | 12.3 inches |
| Resolution | 1920 × 720 pixels |
| Active area | 292.608 × 109.728 mm |
| LCD outline | 309.0 × 128.0 × 6.5 mm |
| Maximum depth at connector | 10.4 mm |
| Brightness | 750 cd/m² |
| Display interface | 2 Port LVDS (DE Only) |
| Connector | 30-pin |
| Touch | Capacitive touch panel |
| Work mode | Transmissive / normally black |
| Operating temperature | −30°C to +85°C |
| Storage temperature | −40°C to +90°C |
| LED lifetime | 20,000 hours, listed reference |
The core size, resolution, LVDS, luminance, temperature, mechanical and LED-life values align with current model-specific technical data.
Wide-Temperature Operation for Industrial HMI
Low temperature can slow LCD response, while heat inside an enclosure can stress the display, backlight, touch stack and nearby electronics. The −30°C to +85°C operating specification gives the project a defined display-level range rather than a general ruggedness claim. Wide-temperature touch products still require complete-system qualification because touch and display behavior can both be temperature-sensitive.
Cold-Start and Hot-Enclosure Qualification
The complete HMI should still be tested at temperature. Touch behavior, controller electronics, cable flexibility, adhesives, backlight behavior and enclosure thermal conditions can influence system performance even when the LCD itself is within its rated range.
Operating Range Is Different from Storage Range
The −40°C to +90°C storage range describes non-operating exposure, not powered performance at those limits. Keep operating and storage conditions separate in environmental test plans.
750-Nit Optical Performance in Bright Ambient Conditions
The 750 cd/m² luminance level is useful for equipment near windows, under strong indoor lighting or in covered environments with elevated ambient illumination. It should not be treated as a finished-system sunlight-readability guarantee. Cover-glass reflectance, air gaps, optical bonding and surface treatment can materially change perceived contrast.
Cover Glass Changes the Optical Result
A capacitive-touch stack may add cover glass, sensor layers and adhesive. Define the final optical stack before approving a brightness target, especially for strong ambient light.
Wide Temperature 750 Nits Touch Display Integration
The display path uses 2 Port LVDS with a 30-pin connection and DE-only timing notation. Those labels narrow controller selection, but they do not establish compatibility with another LVDS panel. Timing, channel mapping, logic voltage, pin assignment and connector orientation must match the host design.
30-Pin LVDS Qualification
A matching 30-pin connector does not guarantee LVDS timing, voltage, channel mapping or pin compatibility. Controller matching should be based on the approved pinout and native 1920 × 720 timing rather than connector count alone.
Capacitive Touch Requires Its Own Interface Definition
Capacitive touch is confirmed, but the touch-controller interface, touch-point count, voltage and firmware requirements still need definition. Do not assume the LVDS image-data path also carries touch data. In comparable TFT assemblies, the TFT/LVDS and PCAP interfaces are defined separately, reinforcing the need to qualify both paths independently.
Mechanical Integration and Enclosure Planning
The LCD body is 309.0 × 128.0 × 6.5 mm, while the connector region reaches a maximum depth of 10.4 mm. Thin enclosures therefore need enough rear clearance for the connector and cable path, not only the nominal LCD thickness.
Active Area and Front Opening
The active image area is 292.608 × 109.728 mm. Front-window opening, bezel overlap and touch-cover geometry should be released from the approved mechanical drawing rather than diagonal size alone.
Connector Clearance
Rear clearance should include the 10.4 mm maximum connector depth plus cable routing. A correct front opening can still fail assembly review if the rear cable is forced against the housing.
Application Fit and Engineering Boundaries
This Wide Temperature 750 Nits Touch Display is best positioned for industrial HMI panels, machinery controls, agricultural equipment displays, smart-home control panels and other professional embedded systems that benefit from a wide horizontal interface and extended temperature range. Kingtech positions the underlying 12.3-inch platform across industrial-control and related embedded-equipment applications.
Industrial and Professional Embedded Equipment
The combination of 1920 × 720 resolution, capacitive touch, 750 cd/m² luminance and −30°C to +85°C operation makes the module relevant where operator interaction and environmental range matter together. Final suitability also depends on host interface, touch electronics, enclosure and optical-stack validation.
Regulated Equipment Requires Finished-Device Qualification
A display specification does not establish medical certification, waterproofing, an IP rating or finished-system regulatory compliance. Regulated equipment should qualify the complete device against its required standards.
Customization and Project Review
Touch-controller selection, LVDS cable definition, cover-lens geometry, optical bonding, brightness configuration, FPC orientation and enclosure adaptation can be reviewed for project requirements.
Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability and the requested specification. Sample and standard-module quantities are confirmed separately.
Procurement Checklist
Before sample approval, confirm the production revision, native 1920 × 720 timing, complete 30-pin LVDS assignment, channel and bit mapping, DE-only timing, panel logic voltage, connector orientation, capacitive-touch controller and interface, touch-point requirement, 292.608 × 109.728 mm active area, 309.0 × 128.0 × 6.5 mm LCD outline, 10.4 mm connector clearance, 750 cd/m² luminance tolerance, operating/storage limits, backlight electrical data, viewing-angle values and final cover stack.



FAQ
About 12.3 Inch Wide Temperature 750 Nits Touch Display
What must be checked before connecting a 30-pin LVDS host?
Does the capacitive touch use the same interface as the LVDS display path?
Is −30°C to +85°C enough for a wide-temperature HMI?
Is 750 cd/m² sufficient behind a cover lens?
Which dimensions should control enclosure release?
Freya Yang