6.86 Inch Compact Vertical Status Interface LCD Panel Bar Display

Product Gallery
Key Specs

Model P/N

HS686019B0

Size

6.86″

Resolution

480×1280

Brightness

500 (Typ.)(cd/m²)

Viewing Angle

85/85/85/85, L/R/U/D

Connector Type

40-pin MIPI

Operating Temp

-20 ~
70 °C

Overall(mm)

66.7(W)×
181.2(H)×
4.4(D)
Upgrade Options (OEM/ODM)

huisoar

HS686019B0

General Features

Brand

huisoar

Panel Size (inch)

6.86"

Model P/N

HS686019B0

Resolution

480×1280

Brightness (nits)

500 cd/m² (Typ.)

Viewing Angle

85/85/85/85, L/R/U/D

Contrast Ratio

1500:1 (Typ.)

Response Time

15ms

Overall (mm)

66.7(W)×
181.2(H) ×
4.4(D) mm

Active Area (mm)

60.19 (W) × 160.51 (H) mm

Refresh Rate

60Hz

Display Colors

16.7M colors

Panel Type

tft-lcd, lcm

Connector Type

40-pin MIPI

Operating Temp

-20 ~
70 °C

Touchscreen Type

Non-touch

Storage Temp

-30 ~ 80 °C

Work Mode

Normally black

Operating Environment

Indoor or controlled-light embedded-equipment installations g(Typ./Max.)

Designed For

Smartwatches Portable medical monitoring devices Drone remote controllers Industrial control panels Handheld gaming consoles Video door-entry intercoms Handheld terminals Automotive instrument clusters Smart central control panels

6.86 Inch Compact Vertical Status Interface LCD Panel

The Compact Vertical Status Interface LCD Panel combines a native 480 × 1280 IPS screen, 500 cd/m² luminance and a 40-pin MIPI connection for narrow embedded controls.

Product Summary

The Compact Vertical Status Interface LCD Panel provides a portrait display area for operating data, menus, alarms and equipment status in products with limited installation width. Its elongated format helps engineering teams organize information from top to bottom without increasing the horizontal footprint of the enclosure.

The 6.86-inch panel offers a 60.19 × 160.51 mm active area inside a slim 66.7 × 181.2 × 4.4 mm outline. It combines IPS viewing, 500 cd/m² typical luminance, a 1500:1 typical contrast ratio and a 40-pin MIPI connection. The standard configuration is non-touch.

Key Specifications

ParameterValue
Display size6.86 inch
Resolution480 × 1280 pixels
FormatPortrait bar, approximately 3:8
Panel typeIPS a-Si TFT-LCD
Optical structureTransmissive
Luminance500 cd/m² typical
Contrast ratio1500:1 typical
Viewing angle85/85/85/85, L/R/U/D
Display colors16.7M
Interface40-pin MIPI
Active area60.19 × 160.51 mm
Overall size66.7 × 181.2 × 4.4 mm
BacklightWLED
TouchNon-touch
Operating temperature−20°C to +70°C
Storage temperature−30°C to +80°C

Native 480 × 1280 Vertical Interface Design

Status, Menu and Alert Zones

The native portrait raster supports information arranged in a logical top-to-bottom sequence. A compact status interface can divide the screen into dedicated areas for:

  • operating mode
  • equipment status
  • temperature or timing
  • alert messages
  • process progress
  • function menus
  • connection state
  • energy data
  • maintenance prompts
  • branded graphics

This layout is useful in smart-appliance controls, industrial equipment, access-control terminals, auxiliary vehicle displays and compact monitoring systems.

Native-Raster Software Preparation

The interface should be designed directly for the native 480 × 1280 raster.

Before approving the software, validate:

  • portrait orientation
  • native timing
  • font scaling
  • icon dimensions
  • list spacing
  • alarm-message position
  • content-safe margins
  • language expansion
  • boot-screen geometry
  • animation behavior

Rotating a completed landscape interface without redesign can produce inconsistent spacing, unused areas and controls that are difficult to scan.

IPS Optical Performance for Compact Equipment

500 cd/m² Luminance Boundary

The panel is specified at 500 cd/m² typical luminance. This supports indoor equipment and controlled environments with moderate ambient lighting.

A 500 cd/m² panel is intended primarily for indoor or controlled-light equipment after front-glass losses are considered.

Finished-system visibility also depends on:

  • front-lens transmission
  • surface reflections
  • air-gap construction
  • optical bonding
  • installation angle
  • room lighting
  • equipment shading
  • operator viewing position

The luminance specification does not independently establish outdoor or direct-sunlight readability.

Viewing Angle, Contrast and Color

The panel provides 85/85/85/85 viewing angles in the left, right, upper and lower directions. This supports equipment viewed from standing, seated or off-center positions.

The 1500:1 typical contrast ratio supports strong separation between background areas, menu labels, icons and alarm graphics. The 16.7M-color capability provides a suitable basis for graphical HMIs, but it does not establish calibrated color accuracy or a particular color gamut.

40-Pin MIPI Host Integration

Lane, Mode and Pinout Qualification

A 40-pin MIPI connector does not guarantee lane, timing, voltage, initialization or pin compatibility with another panel.

Before fabricating an FPC or applying power, confirm:

  • MIPI DSI lane count
  • video or command mode
  • lane rate
  • native 480 × 1280 timing
  • complete 40-pin assignment
  • connector pitch
  • connector contact side
  • FPC orientation
  • panel logic voltage
  • reset and control signals
  • backlight voltage and current
  • backlight enable and dimming
  • cable length and routing

Another 6.86-inch 480 × 1280 MIPI display may use a different connector count, pin map, controller or initialization package.

ST7703I Documentation Boundaries

The ST7703I identifier helps distinguish the display configuration, but it does not independently define the complete host-interface requirements.

Engineering approval should use:

  • the model-specific panel specification
  • complete MIPI timing
  • full pin definition
  • electrical limits
  • initialization commands
  • reset timing
  • power sequence
  • backlight-control definition

Initialization data or register settings from another ST7703I panel should not be copied without model-specific verification.

Compact Vertical Status Interface LCD Panel Mechanics

Active Area and Front Opening

The active image area is 60.19 × 160.51 mm. This value should guide:

  • visible bezel opening
  • front-lens window
  • printed black mask
  • display alignment
  • UI-safe margins
  • menu-column width
  • alarm-icon placement

Critical operating values and warning messages should remain inside the approved visible opening after bezel overlap and production tolerances are applied.

Outline, FPC Routing and Rear Clearance

The complete module measures 66.7 × 181.2 × 4.4 mm.

Mechanical review should confirm:

  • complete panel outline
  • active-area position
  • FPC exit
  • connector location
  • cable bend radius
  • rear clearance
  • mounting support
  • front-lens overlap
  • enclosure tolerances
  • service access

The precise dimensions should control enclosure tooling rather than the rounded 66 × 181 × 4 mm values.

Temperature Qualification

The module is specified for operation from −20°C to +70°C and storage from −30°C to +80°C.

These limits support evaluation in appliances, industrial controls, vehicle auxiliary displays and selected embedded equipment, but they do not independently establish formal qualification for a specific industry.

System-level testing should consider:

  • cold startup
  • high-temperature image behavior
  • backlight output across temperature
  • controller temperature
  • enclosure heat
  • condensation
  • FPC flexibility
  • repeated thermal cycling
  • vibration where applicable

Qualification should use the final controller, front lens and enclosure.

Non-Touch Control Architecture

The standard panel is non-touch. It is suitable where user input is provided through:

  • physical buttons
  • rotary controls
  • membrane keys
  • external capacitive keys
  • remote software
  • system-side controls
  • a separately developed touch assembly

Potential applications include:

  • smart-appliance status panels
  • industrial control interfaces
  • access-control displays
  • compact monitoring terminals
  • vehicle auxiliary information zones
  • vertical instrument panels
  • multimedia status screens
  • narrow embedded HMIs

A non-touch architecture avoids the optical loss, controller integration and added thickness of an integrated touch stack.

Custom Integration Options

Project review may include:

  • MIPI host matching
  • custom 40-pin FPC
  • native timing verification
  • initialization review
  • front-lens sizing
  • anti-glare or anti-reflection treatment
  • optical bonding
  • enclosure adaptation
  • FPC routing
  • branding
  • optional touch development
  • packaging and labeling

Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability and the requested specification. Sample and standard-module quantities are confirmed separately.

Customization for the Compact Vertical Status Interface LCD Panel should begin after the complete MIPI definition and approved mechanical drawing are available.

Procurement Checklist

Before requesting samples or approving production, submit or confirm:

  • native 480 × 1280 timing
  • MIPI DSI lane count
  • video or command mode
  • lane rate
  • complete 40-pin assignment
  • panel logic voltage
  • backlight voltage and current
  • backlight enable and dimming
  • initialization package
  • reset and power sequence
  • connector pitch
  • contact side and FPC orientation
  • 66.7 × 181.2 × 4.4 mm enclosure fit
  • 60.19 × 160.51 mm active-area position
  • front-glass stack
  • 500 cd/m² lighting target
  • operating-temperature requirements
  • non-touch or optional-touch architecture
  • sample quantity
  • annual demand
  • production schedule

Sample approval should precede controller release, FPC manufacture, front-lens tooling and enclosure production.

Application Scenarios

FAQ

About 6.86 Inch Compact Vertical Status Interface LCD Panel

What must be checked before connecting a 40-pin MIPI host?

The host must match the complete interface definition rather than only the connector count. Confirm native 480 × 1280 timing, MIPI lane count, video or command mode, lane rate, full pin assignment, panel voltage, initialization data and backlight controls before applying power.

How should a 480 × 1280 vertical status interface be prepared?

The UI should be created directly for the portrait raster. Arrange equipment status, menus, alarms and operating values vertically rather than rotating a completed landscape design without review. Validate text size and content margins within the 60.19 × 160.51 mm active area.

Is 500 cd/m² sufficient behind a front lens?

It can support many indoor and controlled-light installations, but final visibility depends on lens transmission, reflection, air gaps, optical bonding and installation angle. Test a representative assembly under the intended lighting before approving the lens and enclosure.

What does the ST7703I identifier establish?

It identifies a display-controller reference associated with the panel, but it does not by itself define the complete MIPI mapping, initialization commands, register settings or power sequence. Use the approved model-specific panel documentation for engineering release.

When should the non-touch configuration be selected?

Select the non-touch configuration when the product uses buttons, rotary controls, keys or remote input. It avoids touch-controller integration and additional optical layers. Interactive equipment requires a separately specified sensor, controller, front lens, bonding process and final mechanical stack.

Need a custom solution or samples?

Submit Your Technical Requirements Information to submit: Provide native 480 × 1280 timing, the MIPI lane and mode definition, complete 40-pin assignment, initialization package, panel and backlight power requirements, enclosure and front-lens drawings, lighting conditions, sample quantity and annual demand. Engineering review outcome: The review covers MIPI host compatibility, vertical status-interface mapping, optical performance, temperature qualification, mechanical fit and customization for the Compact Vertical Status Interface LCD Panel.
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.