10.1 Inch 800 Nits Outdoor IPS LCD Module for Industrial HMI

Product Gallery
Key Specs

Model P/N

HS101WHB-NE08

Size

10.1″

Resolution

1280×800

Brightness

800 (Typ.)(cd/m²)

Viewing Angle

85°/85°/85°/85° L/R/U/D

Connector Type

LVDS, 40 pin

Operating Temp

0 ~
50 °C

Overall(mm)

227.91(W)×
148(H)×
8.4(D)
Upgrade Options (OEM/ODM)

huisoar

HS101WHB-NE08

General Features

Brand

huisoar

Panel Size (inch)

10.1"

Model P/N

HS101WHB-NE08

Resolution

1280×800

Brightness (nits)

800 cd/m² (Typ.)

Viewing Angle

85°/85°/85°/85° L/R/U/D

Contrast Ratio

1300:1 typical

Response Time

8ms

Overall (mm)

227.91(W)×
148(H) ×
8.4(D) mm

Active Area (mm)

216.96 × 135.6 mm

Refresh Rate

60Hz

Display Colors

262K / 16.7M listed

Panel Type

tft-lcd, lcm

Connector Type

LVDS, 40 pin

Operating Temp

0 ~
50 °C

Touchscreen Type

Optional Custom Touch Screen

Storage Temp

-20 to +60°C

Work Mode

Normally black, transmissive

Operating Environment

Industrial and bright-ambient embedded equipment; outdoor use requires finished-system environmental qualification g(Typ./Max.)

Designed For

Industrial HMI, digital signage, covered outdoor-facing equipment, vehicle-display and healthcare-equipment integration subject to system qualification

10.1 Inch 800 Nits Outdoor IPS LCD Module for Industrial HMI

This compact 10.1-inch 800 Nits Outdoor IPS LCD Module combines 1280 × 800 resolution with 40-pin LVDS for bright-ambient embedded equipment.

Product Summary

The 800 Nits Outdoor IPS LCD Module is a compact 10.1-inch TFT-LCD component for industrial interfaces and equipment installed in stronger ambient light than a conventional indoor display normally encounters. Its 1280 × 800 pixel matrix uses a practical 16:10 format, while the IPS hard-screen structure supports broad viewing from different operator positions.

The selected configuration provides 800 cd/m² typical luminance. That level creates useful optical headroom for bright indoor locations, sheltered terminals, covered outdoor installations, and equipment positioned near windows. Finished visibility still depends on the front window, reflections, viewing angle, and installation environment, so the LCD should be evaluated as part of the complete equipment optical stack.

Key Specifications

ItemConfirmed value
Screen size10.1 inches
Resolution1280 × 800 pixels, 16:10
Active area216.96 × 135.6 mm
Module outline227.91 × 148 mm
Maximum thickness8.4 mm
Brightness800 cd/m² typical
Panel structureIPS hard-screen family, transmissive
Contrast ratio1300:1 typical
Viewing angle85°/85°/85°/85° L/R/U/D
Display colors262K / 16.7M listed
BacklightWLED
Signal interfaceLVDS, 40 pins
TouchNo touch
Operating temperature0°C to +50°C
Storage temperature−20°C to +60°C

Bright-Ambient Optical Performance

800 cd/m² for Covered Outdoor Equipment

The 800 cd/m² typical luminance is useful where a standard indoor LCD does not provide enough visual margin. Machine panels near factory doors, sheltered public terminals, window-adjacent equipment, and covered outdoor installations can all expose the display to significantly higher ambient illumination.

Luminance alone should not be treated as proof of direct-sun readability. A front lens with high reflectance, an air gap, or unfavorable mounting geometry can reduce effective contrast even when the bare module has higher backlight output. Representative sample testing should therefore use the intended front structure and lighting environment.

IPS Viewing and 1300:1 Contrast

The IPS hard-screen configuration provides a specified 85°/85°/85°/85° viewing angle in left, right, up, and down directions. Together with a 1300:1 typical contrast ratio, this gives designers more freedom when the operator is not positioned directly on the panel centerline.

The listed 262K / 16.7M color modes should be confirmed against the final signal configuration before production graphics are released. The display can support detailed color user interfaces without assuming an unverified bit-depth or LVDS mapping.

Integrating the 800 Nits Outdoor IPS LCD Module

40-Pin LVDS Requires Full Host Matching

The image path uses a 40-pin LVDS connection. A matching connector count does not establish controller compatibility by itself. The host design should confirm native 1280 × 800 timing, complete pin assignment, LVDS channel and bit mapping, connector pitch, contact side, cable orientation, panel voltage, and backlight requirements.

This becomes especially important in replacement programs. Two 10.1-inch modules may share the same resolution, LVDS label, and 40-pin connector while still having different electrical assignments or cable geometry.

Mechanical Fit for Compact Equipment

The active image area measures 216.96 × 135.6 mm. The complete module outline is 227.91 × 148 mm, and maximum thickness is 8.4 mm.

These dimensions perform different design functions. The active area controls the visible image opening, while the complete module geometry determines internal packaging and clearances. Final enclosure tooling should use an approved production drawing that also defines tolerances, mounting details, and cable exit position.

Non-Touch Architecture

Standard Configuration Has No Touchscreen

The standard module is non-touch. Equipment that requires operator interaction should therefore treat touch as a separate subsystem instead of assuming a sensor or controller is included with the LCD.

A separately engineered touch assembly can affect optical transmission, overall thickness, front-window design, grounding, controller routing, and mechanical tolerances. Those items need a combined LCD-and-touch drawing before an interactive front panel is released.

Environmental Boundaries

Operating and Storage Temperature Limits

The confirmed operating range is 0°C to +50°C, while storage is specified from −20°C to +60°C. These values are important when evaluating equipment placed near exterior walls, inside kiosks, or in cabinets affected by solar heating.

The temperature range does not establish waterproofing, UV resistance, condensation resistance, or an IP grade. The complete product enclosure remains responsible for sealing, thermal management, mechanical protection, and any environmental compliance required by the application.

Application Fit

The 800 Nits Outdoor IPS LCD Module is a practical candidate for industrial HMI panels, machinery interfaces, compact digital signage, sheltered outdoor-facing information terminals, and other bright-ambient embedded systems where 10.1-inch WXGA content and LVDS integration are suitable.

Vehicle-display and healthcare-equipment integration may also be evaluated when the finished system completes the necessary electrical, environmental, optical, mechanical, and regulatory qualification. The panel specification alone does not establish vehicle grade, medical certification, or application-specific compliance.

Customization and Qualification

Optical and Mechanical Options

Projects may evaluate cover glass, AR or AG treatment, optical bonding, enclosure adaptation, cable changes, and mechanical adjustments where supporting drawings and performance targets are available. Any change to the front optical stack should be checked against the required finished-system luminance and reflection performance.

Interface and Touch Development

LVDS cable and controller matching can be reviewed using the complete host timing and pin definition. A separate touch system may also be considered where interactive input is required, but touch is not a standard feature of this configuration.

Custom configurations are generally reviewed from 500 pieces, subject to tooling requirements, material availability, and the requested specification. Sample and standard-module quantities are confirmed separately.

Procurement Checklist

  • Confirm the ordered 800 cd/m² grade and luminance tolerance.
  • Provide native 1280 × 800 host timing.
  • Confirm complete 40-pin LVDS pin assignment and channel/bit mapping.
  • Confirm connector pitch, contact side, cable direction, and mating connector.
  • Obtain panel input voltage and WLED voltage/current/control requirements.
  • Approve the 216.96 × 135.6 mm active area.
  • Approve the 227.91 × 148 mm outline and 8.4 mm maximum thickness.
  • Confirm 1300:1 typical contrast and the required color mode.
  • Keep the standard product identified as non-touch unless an approved touch assembly is added.
  • Validate 0°C to +50°C operation against actual equipment temperature.
  • Define front-glass transmission, reflection, sealing, humidity, vibration, and compliance targets.
  • Specify sample acceptance criteria, quantity, annual demand, and schedule.

Application Scenarios

FAQ

About 10.1 Inch 800 Nits Outdoor IPS LCD Module

What must be checked before replacing another 40-pin LVDS panel?

A 40-pin connector should never be treated as a universal replacement standard. Confirm the complete pin assignment, native 1280 × 800 timing, LVDS channel and bit mapping, panel supply, connector orientation, and backlight requirements. The 227.91 × 148 mm outline and 8.4 mm maximum thickness should also be compared with the existing enclosure before approving a replacement sample.

Is 800 cd/m² sufficient for equipment installed in direct sunlight?

It provides a stronger starting point than a conventional indoor display, but direct-sun performance must be validated in the finished equipment. The 800 cd/m² panel output can be reduced by front-window transmission losses and overwhelmed by reflections. Submit the final cover-glass structure, installation angle, screen setback, and lighting conditions so the optical target can be evaluated under representative conditions.

How should the front glass be evaluated with this LCD?

Evaluate the complete optical stack rather than the bare panel alone. The module provides 800 cd/m² typical luminance and 1300:1 typical contrast, but cover-glass transmission and surface reflections influence the contrast seen by the operator. A production review should therefore define glass material, coating, air gap or bonding method, and the expected lighting environment before the final front structure is released.

Is touch included with the standard module?

No. The confirmed configuration is non-touch. If the equipment requires interactive input, the touch technology, controller interface, cover lens, bonding method, combined thickness, and mechanical outline need separate definition. The original 227.91 × 148 mm LCD outline and 8.4 mm maximum thickness should not be assumed to represent the final dimensions of a customized touch assembly.

How does the 0°C to +50°C operating range affect outdoor equipment design?

The LCD must remain within 0°C to +50°C during operation even if the finished equipment is installed outdoors. Cabinet temperature can differ substantially from ambient temperature because of solar loading and internal electronics. Projects facing colder starts or hotter internal conditions should provide the expected temperature profile before committing to this grade or releasing the enclosure and thermal design.

Need a custom solution or samples?

Submit Requirements for Engineering Review For an 800 Nits Outdoor IPS LCD Module project, submit native 1280 × 800 timing, the complete 40-pin LVDS definition, connector and cable information, panel and WLED electrical requirements, enclosure and front-window drawings, lighting conditions, operating-temperature target, touch requirement, sample quantity, and annual demand. Engineering review covers signal compatibility, optical performance, mechanical fit, temperature limits, front-stack requirements, and any separately specified touch system.
Scroll to Top
Request Quote / Datasheet

Response within 12-24 hours. NDA available. Engineering support included.

Fields marked with an asterisk (*) are required.

Contact Information

Request Details

WeChat QR code

Scan the QR code with your phone to contact us.

Download Datasheet

Please input your e-mail address to start the download.